Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BYFrontiers in medicine

Proportional conservation of vectorial non-summation in corneal astigmatism: a thick-lens analysis in normal and keratoconic eyes.

8 affiliations
  1. 1Department of Ophthalmology and Corneal/Refractive Surgery, Eye Institute, Parauapebas, Pará, Brazil.
  2. 2NewVision Clinics, Melbourne, VIC, Australia.
  3. 3TECLens, LLC, Stamford, CT, United States.
  4. 4Computing Institute, Federal University of Alagoas (UFAL), Maceió, Brazil.
  5. 5Department of Ophthalmology, Federal University of São Paulo (UNIFESP), São Paulo, Brazil.
  6. 6Brazilian Artificial Intelligence Network in Medicine (BrAIN), Rio de Janeiro, Brazil.
  7. 7Ophthalmology Department, Alder Hey Children's NHS Foundation Trust, Liverpool, United Kingdom.
  8. 8Department of Ophthalmology, Federal University of the State of Rio de Janeiro (UNIRIO), Rio de Janeiro, Brazil.

Abstract

Purpose

To test whether the residual between ray-traced total corneal astigmatism and the vector sum of the anterior and posterior second-order astigmatic components is an independent, disease-related signal or a proportionally conserved feature of corneal thick-lens optics.Methods

Secondary analysis of a deidentified multicenter database of unoperated eyes examined with Pentacam HR and Corvis ST, restricted to clinically normal eyes and bilateral keratoconus, one eye per subject (1,680 normal; 1,181 keratoconic). Second-order Zernike astigmatic vectors were extracted over a 6.0 mm zone for the anterior (F) and posterior (B) surfaces and the ray-traced total cornea (T). The primary endpoint was the non-summation magnitude |T-F-B|. Pre-specified secondary analyses normalized the residual to total and anterior astigmatism, examined meridional-axis behavior, and tested associations with dynamic corneal response and composite indices. A sensitivity analysis added very asymmetric ectasia eyes.Results

Absolute non-summation was greater in keratoconic than in normal eyes (median 0.223 vs 0.155 µm; P < 0.001; Cliff's δ = 0.225, a small effect), but every astigmatic magnitude was scaled by a similar factor (anterior ×1.48, posterior ×1.28, total ×1.52, non-summation ×1.43). Within each group the residual was near-collinear with anterior astigmatism (Spearman ρ = 0.99), and its normalized fraction was essentially identical in normal and keratoconic eyes (median 0.149 vs. 0.147; Cliff's δ = -0.06) and in both eyes of patients with very asymmetric ectasia (0.147-0.149). Front-back meridional misalignment did not differ (5.89° vs. 5.63°; P = 0.49). Partial correlations with dynamic corneal response and composite indices, adjusted for astigmatism magnitude, were uniformly weak (|ρ| < 0.11).Conclusions

Corneal astigmatism is not fully described by vector summation of the two surfaces. The residual, compatible with thick-lens coupling and device-specific optical conventions, is larger in absolute terms in keratoconus but represents a constant proportion of each eye's astigmatism across the ectatic spectrum. We interpret it as a magnitude-coupled optical descriptor, not an independent diagnostic or biomechanical signal. Clinically, these findings caution against assuming direct additivity of the exported anterior and posterior astigmatic components; implications for toric and refractive planning require validation against clinically relevant optical outputs and postoperative outcomes. Future studies should model corneal and tear-film refractive-index effects explicitly.

Related

  1. Multivariate Analysis of the Spatial Distance Between the Corneal Thinnest Point and Maximum Keratometry in Keratoconic Corneas: Association with Disease Severity
    Umberto Camellin, Marco Lombardo, Francesco Franchina +6
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Biomechanical stabilization of the keratoconic cornea: a review of current therapeutic strategies.
    Graziana M Ragonese, Edoardo Grosso, Dario Carbonaro +3
    Frontiers in medical technologyPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMCPMC
  3. Quantitation of stromal distortion across the full depth of keratoconic corneas
    Poncia Nyembo Kasongo, Djida Ghoubay, Jean-Marc Allain +5
    Investigative Ophthalmology & Visual SciencePeer-reviewedCC BY 4.0Full textSystems & synthetic biologyMedical imaging & radiologyHALPMC
  4. Hypoosmolar riboflavin for corneal swelling in thin keratoconic corneas prior to crosslinking: An exploratory study
    Clark Y. Chang, Subba R. Gollamudi, Daniel G. Fuller +1
    Therapeutic Advances in OphthalmologyPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
  5. A Rare Presentation of Epithelial Downgrowth Following Incisional Astigmatism Correction.
    Mohammadali Javadi, Mozhgan Rezaei Kanavi, Elaheh Arasteh +1
    Journal of ophthalmic & vision researchPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
BibTeX
@article{bragareis2026proportional,
  title = {{Proportional conservation of vectorial non-summation in corneal astigmatism: a thick-lens analysis in normal and keratoconic eyes.}},
  author = {Miguel Braga-Reis and Noel A Alpins and James K Y Ong and Ibrahim Seven and Patrick Lopath and Aydano P Machado and Bernardo T Lopes and Karolyna Carvalho and Renato Ambrósio},
  journal = {Frontiers in medicine},
  year = {2026},
  month = nov,
  doi = {10.3389/fmed.2026.1935822},
  url = {https://europepmc.org/article/MED/43080410},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Proportional conservation of vectorial non-summation in corneal astigmatism: a thick-lens analysis in normal and keratoconic eyes.
AU  - Miguel Braga-Reis
AU  - Noel A Alpins
AU  - James K Y Ong
AU  - Ibrahim Seven
AU  - Patrick Lopath
AU  - Aydano P Machado
AU  - Bernardo T Lopes
AU  - Karolyna Carvalho
AU  - Renato Ambrósio
PY  - 2026
DA  - 2026/11/10
JO  - Frontiers in medicine
DO  - 10.3389/fmed.2026.1935822
UR  - https://europepmc.org/article/MED/43080410
AB  - Purpose  To test whether the residual between ray-traced total corneal astigmatism and the vector sum of the anterior and posterior second-order astigmatic components is an independent, disease-related signal or a proportionally conserved feature of corneal thick-lens optics.Methods  Secondary analysis of a deidentified multicenter database of unoperated eyes examined with Pentacam HR and Corvis ST, restricted to clinically normal eyes and bilateral keratoconus, one eye per subject (1,680 normal; 1,181 keratoconic). Second-order Zernike astigmatic vectors were extracted over a 6.0 mm zone for the anterior (F) and posterior (B) surfaces and the ray-traced total cornea (T). The primary endpoint was the non-summation magnitude |T-F-B|. Pre-specified secondary analyses normalized the residual to total and anterior astigmatism, examined meridional-axis behavior, and tested associations with dynamic corneal response and composite indices. A sensitivity analysis added very asymmetric ectasia eyes.Results  Absolute non-summation was greater in keratoconic than in normal eyes (median 0.223 vs 0.155 µm; P < 0.001; Cliff's δ = 0.225, a small effect), but every astigmatic magnitude was scaled by a similar factor (anterior ×1.48, posterior ×1.28, total ×1.52, non-summation ×1.43). Within each group the residual was near-collinear with anterior astigmatism (Spearman ρ = 0.99), and its normalized fraction was essentially identical in normal and keratoconic eyes (median 0.149 vs. 0.147; Cliff's δ = -0.06) and in both eyes of patients with very asymmetric ectasia (0.147-0.149). Front-back meridional misalignment did not differ (5.89° vs. 5.63°; P = 0.49). Partial correlations with dynamic corneal response and composite indices, adjusted for astigmatism magnitude, were uniformly weak (|ρ| < 0.11).Conclusions  Corneal astigmatism is not fully described by vector summation of the two surfaces. The residual, compatible with thick-lens coupling and device-specific optical conventions, is larger in absolute terms in keratoconus but represents a constant proportion of each eye's astigmatism across the ectatic spectrum. We interpret it as a magnitude-coupled optical descriptor, not an independent diagnostic or biomechanical signal. Clinically, these findings caution against assuming direct additivity of the exported anterior and posterior astigmatic components; implications for toric and refractive planning require validation against clinically relevant optical outputs and postoperative outcomes. Future studies should model corneal and tear-film refractive-index effects explicitly.
SN  - 2296-858X
ER  -