Proportional conservation of vectorial non-summation in corneal astigmatism: a thick-lens analysis in normal and keratoconic eyes.
8 affiliations
- 1Department of Ophthalmology and Corneal/Refractive Surgery, Eye Institute, Parauapebas, Pará, Brazil.
- 2NewVision Clinics, Melbourne, VIC, Australia.
- 3TECLens, LLC, Stamford, CT, United States.
- 4Computing Institute, Federal University of Alagoas (UFAL), Maceió, Brazil.
- 5Department of Ophthalmology, Federal University of São Paulo (UNIFESP), São Paulo, Brazil.
- 6Brazilian Artificial Intelligence Network in Medicine (BrAIN), Rio de Janeiro, Brazil.
- 7Ophthalmology Department, Alder Hey Children's NHS Foundation Trust, Liverpool, United Kingdom.
- 8Department of Ophthalmology, Federal University of the State of Rio de Janeiro (UNIRIO), Rio de Janeiro, Brazil.
Abstract
Purpose
To test whether the residual between ray-traced total corneal astigmatism and the vector sum of the anterior and posterior second-order astigmatic components is an independent, disease-related signal or a proportionally conserved feature of corneal thick-lens optics.Methods
Secondary analysis of a deidentified multicenter database of unoperated eyes examined with Pentacam HR and Corvis ST, restricted to clinically normal eyes and bilateral keratoconus, one eye per subject (1,680 normal; 1,181 keratoconic). Second-order Zernike astigmatic vectors were extracted over a 6.0 mm zone for the anterior (F) and posterior (B) surfaces and the ray-traced total cornea (T). The primary endpoint was the non-summation magnitude |T-F-B|. Pre-specified secondary analyses normalized the residual to total and anterior astigmatism, examined meridional-axis behavior, and tested associations with dynamic corneal response and composite indices. A sensitivity analysis added very asymmetric ectasia eyes.Results
Absolute non-summation was greater in keratoconic than in normal eyes (median 0.223 vs 0.155 µm; P < 0.001; Cliff's δ = 0.225, a small effect), but every astigmatic magnitude was scaled by a similar factor (anterior ×1.48, posterior ×1.28, total ×1.52, non-summation ×1.43). Within each group the residual was near-collinear with anterior astigmatism (Spearman ρ = 0.99), and its normalized fraction was essentially identical in normal and keratoconic eyes (median 0.149 vs. 0.147; Cliff's δ = -0.06) and in both eyes of patients with very asymmetric ectasia (0.147-0.149). Front-back meridional misalignment did not differ (5.89° vs. 5.63°; P = 0.49). Partial correlations with dynamic corneal response and composite indices, adjusted for astigmatism magnitude, were uniformly weak (|ρ| < 0.11).Conclusions
Corneal astigmatism is not fully described by vector summation of the two surfaces. The residual, compatible with thick-lens coupling and device-specific optical conventions, is larger in absolute terms in keratoconus but represents a constant proportion of each eye's astigmatism across the ectatic spectrum. We interpret it as a magnitude-coupled optical descriptor, not an independent diagnostic or biomechanical signal. Clinically, these findings caution against assuming direct additivity of the exported anterior and posterior astigmatic components; implications for toric and refractive planning require validation against clinically relevant optical outputs and postoperative outcomes. Future studies should model corneal and tear-film refractive-index effects explicitly.
Related
- Multivariate Analysis of the Spatial Distance Between the Corneal Thinnest Point and Maximum Keratometry in Keratoconic Corneas: Association with Disease Severity
- Biomechanical stabilization of the keratoconic cornea: a review of current therapeutic strategies.
- Quantitation of stromal distortion across the full depth of keratoconic corneas
- Hypoosmolar riboflavin for corneal swelling in thin keratoconic corneas prior to crosslinking: An exploratory study
- A Rare Presentation of Epithelial Downgrowth Following Incisional Astigmatism Correction.
BibTeX
@article{bragareis2026proportional,
title = {{Proportional conservation of vectorial non-summation in corneal astigmatism: a thick-lens analysis in normal and keratoconic eyes.}},
author = {Miguel Braga-Reis and Noel A Alpins and James K Y Ong and Ibrahim Seven and Patrick Lopath and Aydano P Machado and Bernardo T Lopes and Karolyna Carvalho and Renato Ambrósio},
journal = {Frontiers in medicine},
year = {2026},
month = nov,
doi = {10.3389/fmed.2026.1935822},
url = {https://europepmc.org/article/MED/43080410},
note = {CC BY},
}
RIS
TY - JOUR
TI - Proportional conservation of vectorial non-summation in corneal astigmatism: a thick-lens analysis in normal and keratoconic eyes.
AU - Miguel Braga-Reis
AU - Noel A Alpins
AU - James K Y Ong
AU - Ibrahim Seven
AU - Patrick Lopath
AU - Aydano P Machado
AU - Bernardo T Lopes
AU - Karolyna Carvalho
AU - Renato Ambrósio
PY - 2026
DA - 2026/11/10
JO - Frontiers in medicine
DO - 10.3389/fmed.2026.1935822
UR - https://europepmc.org/article/MED/43080410
AB - Purpose To test whether the residual between ray-traced total corneal astigmatism and the vector sum of the anterior and posterior second-order astigmatic components is an independent, disease-related signal or a proportionally conserved feature of corneal thick-lens optics.Methods Secondary analysis of a deidentified multicenter database of unoperated eyes examined with Pentacam HR and Corvis ST, restricted to clinically normal eyes and bilateral keratoconus, one eye per subject (1,680 normal; 1,181 keratoconic). Second-order Zernike astigmatic vectors were extracted over a 6.0 mm zone for the anterior (F) and posterior (B) surfaces and the ray-traced total cornea (T). The primary endpoint was the non-summation magnitude |T-F-B|. Pre-specified secondary analyses normalized the residual to total and anterior astigmatism, examined meridional-axis behavior, and tested associations with dynamic corneal response and composite indices. A sensitivity analysis added very asymmetric ectasia eyes.Results Absolute non-summation was greater in keratoconic than in normal eyes (median 0.223 vs 0.155 µm; P < 0.001; Cliff's δ = 0.225, a small effect), but every astigmatic magnitude was scaled by a similar factor (anterior ×1.48, posterior ×1.28, total ×1.52, non-summation ×1.43). Within each group the residual was near-collinear with anterior astigmatism (Spearman ρ = 0.99), and its normalized fraction was essentially identical in normal and keratoconic eyes (median 0.149 vs. 0.147; Cliff's δ = -0.06) and in both eyes of patients with very asymmetric ectasia (0.147-0.149). Front-back meridional misalignment did not differ (5.89° vs. 5.63°; P = 0.49). Partial correlations with dynamic corneal response and composite indices, adjusted for astigmatism magnitude, were uniformly weak (|ρ| < 0.11).Conclusions Corneal astigmatism is not fully described by vector summation of the two surfaces. The residual, compatible with thick-lens coupling and device-specific optical conventions, is larger in absolute terms in keratoconus but represents a constant proportion of each eye's astigmatism across the ectatic spectrum. We interpret it as a magnitude-coupled optical descriptor, not an independent diagnostic or biomechanical signal. Clinically, these findings caution against assuming direct additivity of the exported anterior and posterior astigmatic components; implications for toric and refractive planning require validation against clinically relevant optical outputs and postoperative outcomes. Future studies should model corneal and tear-film refractive-index effects explicitly.
SN - 2296-858X
ER -