Broadband radio-frequency TEM specimen holders for in situ biasing excitation and 100-ps-scale electron beam control
Abstract
Broadband electrical excitation inside a transmission electron microscope (TEM) is required to investigate electrically driven nanodevices at their actual operating frequencies and to develop fully electrical time-resolved experiments at a sub-nanosecond range. Here, we report the performances of homemade two- and four-channel radio-frequency (RF) TEM specimen holders based on a hybrid architecture combining coaxial transmission lines with miniaturized impedance-controlled printed circuit boards (PCB). Removable mechanical contacts provide direct electrical connection to interchangeable TEM chips without wire bonding. Vector network analyzer measurements demonstrate broadband transmission through the complete electrical path up to the specimen. With a representative TEM chip, the two-channel holder exhibits a -3 dB bandwidth of 7.9 GHz, while insertion losses remain below 12 dB up to 18 GHz. The same RF holder architecture was used to drive a miniaturized electrostatic electron-beam deflector. The measured temporal response indicates that the holder deflector assembly remains compatible with electrical pulse durations approaching 100 ps, with the shortest accessible times presently limited by the available waveform generator. High-resolution TEM imaging with a 200 ps probe window does not show detectable degradation of spatial resolution, while off-axis electron holography is successfully performed for probe durations down to 0.5 ns under conditions representative of operando measurements. These results establish a versatile broadband platform combining GHz electrical excitation and sub-nanosecond electron-beam control. The dual-stage configuration of our Hitachi HF3300 microscope further provides the basis for a future fully electrical pump-probe TEM approach using independently driven RF holders for specimen excitation and electron-probe control.
Related
- Quantum environment afterglow from broadband excitation spectroscopy in superconducting qubits
- Role of population depletion in shaping the intensity dependence of electron excitation
- Electronic-Structure Control of Nuclear Excitation by Electron Capture in Finite-Density 229Th
- Zero-forward Kerker scattering via synthesized complex-frequency excitation
- Breaking Rayleigh’s curse: broadband frequency super-resolution via a quantum harmonic oscillator
BibTeX
@misc{gatel2026broadband,
title = {{Broadband radio-frequency TEM specimen holders for in situ biasing excitation and 100-ps-scale electron beam control}},
author = {Christophe Gatel and Marine Resano and Bérangère Disic and Nasibeh Parsaei and Emmanuel Perrin and Hervé Parvery and Romain Queslier and Bertrand Gatti and Pierre Abeilhou and Alexandre Alibert and Christian Pertel and Cécile Marcelot and Nicolas Biziere},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.21275},
eprint = {2610.21275},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.21275},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Broadband radio-frequency TEM specimen holders for in situ biasing excitation and 100-ps-scale electron beam control
AU - Christophe Gatel
AU - Marine Resano
AU - Bérangère Disic
AU - Nasibeh Parsaei
AU - Emmanuel Perrin
AU - Hervé Parvery
AU - Romain Queslier
AU - Bertrand Gatti
AU - Pierre Abeilhou
AU - Alexandre Alibert
AU - Christian Pertel
AU - Cécile Marcelot
AU - Nicolas Biziere
PY - 2026
DA - 2026/10/15
PB - arXiv
DO - 10.48550/arxiv.2610.21275
UR - https://arxiv.org/abs/2610.21275
AB - Broadband electrical excitation inside a transmission electron microscope (TEM) is required to investigate electrically driven nanodevices at their actual operating frequencies and to develop fully electrical time-resolved experiments at a sub-nanosecond range. Here, we report the performances of homemade two- and four-channel radio-frequency (RF) TEM specimen holders based on a hybrid architecture combining coaxial transmission lines with miniaturized impedance-controlled printed circuit boards (PCB). Removable mechanical contacts provide direct electrical connection to interchangeable TEM chips without wire bonding. Vector network analyzer measurements demonstrate broadband transmission through the complete electrical path up to the specimen. With a representative TEM chip, the two-channel holder exhibits a -3 dB bandwidth of 7.9 GHz, while insertion losses remain below 12 dB up to 18 GHz. The same RF holder architecture was used to drive a miniaturized electrostatic electron-beam deflector. The measured temporal response indicates that the holder deflector assembly remains compatible with electrical pulse durations approaching 100 ps, with the shortest accessible times presently limited by the available waveform generator. High-resolution TEM imaging with a 200 ps probe window does not show detectable degradation of spatial resolution, while off-axis electron holography is successfully performed for probe durations down to 0.5 ns under conditions representative of operando measurements. These results establish a versatile broadband platform combining GHz electrical excitation and sub-nanosecond electron-beam control. The dual-stage configuration of our Hitachi HF3300 microscope further provides the basis for a future fully electrical pump-probe TEM approach using independently driven RF holders for specimen excitation and electron-probe control.