Perceived sound quality and speech recognition are not interchangeable outcome measures in adult cochlear implant users.
- 1Department of Otolaryngology, Hannover Medical School, Hannover, Germany.
- 2Cluster of Excellence "Hearing4All", Hannover, Germany.
- 3College of Health Solutions, Arizona State University, Tempe, AZ, United States.
Abstract
Introduction
This study examined whether descriptor-based reports of perceived sound quality in adult cochlear implant users are associated with speech-recognition outcomes, preoperative maximum monosyllabic word recognition, and patient- or device-related factors.Methods
In this retrospective single-center analysis, 249 adult cochlear implant users completed a 25-item descriptor-based sound-quality assessment covering retrospectively recalled early (T1) and current (T2) listening experience. Descriptor profiles and superordinate descriptor groups were linked to preoperative maximum monosyllabic word recognition and postoperative speech-recognition outcomes in quiet and noise using group comparisons, univariate logistic regression, and multiple linear regression of rank-transformed objective outcomes, with false-discovery-rate correction.Results
Individual sound-quality descriptors were not robustly associated with concurrent or later speech-recognition performance. Preoperative maximum monosyllabic word recognition was not robustly associated with later descriptor profiles. Patient- and device-related factors showed selective associations with descriptor endorsement. Among nominally significant associations in adjusted models, descriptors and supergroups explained 1.5-3.2 percentage points of additional variance in speech-recognition outcomes and 1.8-3.3 percentage points in preoperative maximum monosyllabic word recognition beyond patient- and device-related factors.Conclusion
Speech-recognition measures do not reliably capture perceived cochlear implant sound quality. Structured sound-quality assessment may add clinically relevant information beyond standard speech testing, particularly when subjective listening experience and conventional outcome measures do not align.
Related
- Associations of Word Recognition in Noise with Perceived Hearing Handicap and Quality of Life in Older Adults with Sensorineural Hearing Loss.
- Spectro-temporal modulation sensitivity prospectively predicts speech-in-noise recognition in cochlear implant users
- Perceived stress mediates the longitudinal effect of sleep quality on internalizing symptoms
- Comparing prescribing and spending across originator, follow-on, and interchangeable biosimilar insulin glargine: Opportunities to improve uptake of biosimilar medications
- Long-term impact of the diagnosis on quality of life, social skills, and person recognition strategies in congenital prosopagnosics: A cross-sectional study
BibTeX
@article{buczak2026perceived,
title = {{Perceived sound quality and speech recognition are not interchangeable outcome measures in adult cochlear implant users.}},
author = {Nadine Buczak and Michael F Dorman and Anke Leichtle and Andreas Büchner},
journal = {Frontiers in human neuroscience},
year = {2026},
month = nov,
doi = {10.3389/fnhum.2026.1968712},
url = {https://europepmc.org/article/MED/43080347},
note = {CC BY},
}
RIS
TY - JOUR
TI - Perceived sound quality and speech recognition are not interchangeable outcome measures in adult cochlear implant users.
AU - Nadine Buczak
AU - Michael F Dorman
AU - Anke Leichtle
AU - Andreas Büchner
PY - 2026
DA - 2026/11/10
JO - Frontiers in human neuroscience
DO - 10.3389/fnhum.2026.1968712
UR - https://europepmc.org/article/MED/43080347
AB - Introduction This study examined whether descriptor-based reports of perceived sound quality in adult cochlear implant users are associated with speech-recognition outcomes, preoperative maximum monosyllabic word recognition, and patient- or device-related factors.Methods In this retrospective single-center analysis, 249 adult cochlear implant users completed a 25-item descriptor-based sound-quality assessment covering retrospectively recalled early (T1) and current (T2) listening experience. Descriptor profiles and superordinate descriptor groups were linked to preoperative maximum monosyllabic word recognition and postoperative speech-recognition outcomes in quiet and noise using group comparisons, univariate logistic regression, and multiple linear regression of rank-transformed objective outcomes, with false-discovery-rate correction.Results Individual sound-quality descriptors were not robustly associated with concurrent or later speech-recognition performance. Preoperative maximum monosyllabic word recognition was not robustly associated with later descriptor profiles. Patient- and device-related factors showed selective associations with descriptor endorsement. Among nominally significant associations in adjusted models, descriptors and supergroups explained 1.5-3.2 percentage points of additional variance in speech-recognition outcomes and 1.8-3.3 percentage points in preoperative maximum monosyllabic word recognition beyond patient- and device-related factors.Conclusion Speech-recognition measures do not reliably capture perceived cochlear implant sound quality. Structured sound-quality assessment may add clinically relevant information beyond standard speech testing, particularly when subjective listening experience and conventional outcome measures do not align.