PreprintarXiv licencearXiv
Comment on "Note on the start-up of Couette flow for viscoelastic fluids" [Phys. Fluids 35, 113108 (2023)]
Abstract
I show that the initial conditions imposed by Balan [Phys. Fluids 35, 113108 (2023)] are incompatible with a nonzero retardation time, so that the problem solved is not impulsive start-up, but, as I prove exactly, the start-up of a plate ramped as 1 − e−t/λ2 on the retardation timescale λ2 (a material parameter, not a setting in a rheometer). Values digitized from that paper's viscoelastic figures fall on the ramped-plate solution, not on Tanner's start-up solution. The large negative wall normal stress reported for the corotational model is a grid-dependent artifact due to the same error in the initial data. An open-source code repository provides annotated notebooks reproducing every figure and number in this Comment.
Related
- Competing instabilities in wide-gap viscoelastic Taylor-Couette flow: Taylor vs. helical vortices
- Geometry-Controlled Relaxation Spectra in Viscoelastic Fluids
- Data-Driven Design Optimization of Streaming-Potential-Mediated Electrokinetic Transport of Viscoelastic Fluids in Microchannels
- Inertialess instability of elasto-viscoplastic circular Couette flow
- Nonhomogeneous elastic turbulence in the two-dimensional Taylor-Couette flow
BibTeX
@misc{christov2026comment,
title = {{Comment on "Note on the start-up of Couette flow for viscoelastic fluids" [Phys. Fluids 35, 113108 (2023)]}},
author = {Ivan C. Christov},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2609.30359},
eprint = {2609.30359},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2609.30359},
}
RIS
TY - UNPB
TI - Comment on "Note on the start-up of Couette flow for viscoelastic fluids" [Phys. Fluids 35, 113108 (2023)]
AU - Ivan C. Christov
PY - 2026
DA - 2026/09/28
PB - arXiv
DO - 10.48550/arxiv.2609.30359
UR - https://arxiv.org/abs/2609.30359
AB - I show that the initial conditions imposed by Balan [Phys. Fluids 35, 113108 (2023)] are incompatible with a nonzero retardation time, so that the problem solved is not impulsive start-up, but, as I prove exactly, the start-up of a plate ramped as 1 − e^−t/λ_2 on the retardation timescale λ_2 (a material parameter, not a setting in a rheometer). Values digitized from that paper's viscoelastic figures fall on the ramped-plate solution, not on Tanner's start-up solution. The large negative wall normal stress reported for the corotational model is a grid-dependent artifact due to the same error in the initial data. An open-source code repository provides annotated notebooks reproducing every figure and number in this Comment.
ER -