Skip to content
DraconiticResearch
Search Sources API
181,716 studies31 sourcesUpdated 5 min ago
Peer-reviewedCC BYAudiology research

Audiometric, Perceptual and Subjective Cognitive Assessment of Hearing Loss in Adults with Hearing-Related Complaints.

  1. 1Department of Otolaryngology, Head and Neck Surgery, De La Merced University Hospital, 41640 Osuna, Spain.
  2. 2Department of Otolaryngology, Head and Neck Surgery, Virgen Macarena University Hospital, 41009 Seville, Spain.

Abstract

Background: Pure-tone audiometry (PTA) does not fully capture functional hearing difficulties. This study examined relationships between audiometric thresholds, self-reported hearing quality (SSQ12), and cognitive screening in patients with auditory complaints, as well as the association of other factors such as age and noise exposure with these measures. Methods: Data from 178 patients complaining about subjective hearing loss (mean age 55 ± 17.4 years; 43.3% male), including PTA and SSQ12, were analyzed. A subgroup of 60 patients aged ≥ 60 years also completed the Subjective Cognitive Decline Questionnaire (MiCog/SuCog). Associations were assessed via bivariate correlation and multiple linear regression analyses. Results: Age was independently associated with higher PTA4 thresholds in both ears (right: B = 0.60 dB HL per year, 95% CI 0.47-0.73; left: B = 0.61 dB HL per year, 95% CI 0.48-0.74; p < 0.001). SSQ12 scores correlated with PTA (right ear ρ = -0.532) and age (ρ = -0.283; both p < 0.001) and were lower in noise-exposed participants after adjusting for PTA, age, sex and tinnitus (B = -1.005, 95% CI -1.565 to -0.446, p < 0.001). In the cognitive subgroup, right-ear PTA showed an unadjusted correlation with MiCog (ρ = 0.332, p = 0.010); in the adjusted model, neither PTA nor any other predictor was independently associated with MiCog (PTA: B = 0.095, 95% CI -0.075 to 0.264, p = 0.266). No significant association was found between MiCog and the SSQ12 total score (Pearson r = -0.166, p = 0.204; Spearman ρ = -0.241, p = 0.064). Conclusions: Audiometric thresholds, self-reported hearing quality, and cognitive screening capture partially distinct, interrelated dimensions of auditory function. Self-reported measures revealed noise-related difficulties undetected by audiometry. These findings support incorporating patient- and informant-reported outcomes alongside audiometry to support a more comprehensive, patient-centered approach to hearing and cognitive care.

Related

  1. Personalized assessment of high-definition slow-oscillatory transcranial direct current stimulation (so-tDCS) in older adults with sleep and subjective cognitive complaints: A study protocol for a randomized clinical trial
    Hanna Lu, Xi Ni, Natalie Shu Yang +3
    PLOS OnePeer-reviewedCC BY 4.0Full textNeuroscienceClinical trials & evidence synthesisPLOS
  2. A registered report on interruptions during visual search: Examining the effects of perceptual and cognitive load.
    Emily Seeligmüller, Jeremy M Wolfe, Jan Philipp Röer
    Attention, perception & psychophysicsPeer-reviewedCC BYFull textNeuroscienceEurope PMCPMC
  3. Cognitive workload across subjective and electrodermal measures in relation to previous-night sleep
    Maciej Lachowicz, Iwona Wilk, Igor Hrehorowicz +5
    Frontiers in CognitionPeer-reviewedCC BY 4.0Full textNeurosciencePMC
  4. Cognitive Assessment Tools Developed or Adapted for Indigenous Populations in North America, South America, and Oceania: A Systematic Review
    Jaden Seligman, Marianne Galliez, Anne-Marie Ergis +1
    PsyArXivPreprintAll rights reservedFull textNeuroscienceOSF
  5. Microwave Encephalography (MWEG) for Non-Invasive Assessment of Cognitive States: Signal Processing and Functional Hemispheric Asymmetry
    L. I. Brusilovsky, A. S. Bryukhovetskiy, S. P. Kozhin
    bioRxivPreprintCC BY-NC-NDFull textNeurosciencebioRxiv
BibTeX
@article{alvarezcendrero2026audiometric,
  title = {{Audiometric, Perceptual and Subjective Cognitive Assessment of Hearing Loss in Adults with Hearing-Related Complaints.}},
  author = {Marta Álvarez-Cendrero and Andrea Rodríguez Rodero and María A Callejón-Leblic},
  journal = {Audiology research},
  year = {2026},
  month = oct,
  doi = {10.3390/audiolres16050150},
  url = {https://europepmc.org/article/MED/42930348},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Audiometric, Perceptual and Subjective Cognitive Assessment of Hearing Loss in Adults with Hearing-Related Complaints.
AU  - Marta Álvarez-Cendrero
AU  - Andrea Rodríguez Rodero
AU  - María A Callejón-Leblic
PY  - 2026
DA  - 2026/10/01
JO  - Audiology research
DO  - 10.3390/audiolres16050150
UR  - https://europepmc.org/article/MED/42930348
AB  - Background: Pure-tone audiometry (PTA) does not fully capture functional hearing difficulties. This study examined relationships between audiometric thresholds, self-reported hearing quality (SSQ12), and cognitive screening in patients with auditory complaints, as well as the association of other factors such as age and noise exposure with these measures. Methods: Data from 178 patients complaining about subjective hearing loss (mean age 55 ± 17.4 years; 43.3% male), including PTA and SSQ12, were analyzed. A subgroup of 60 patients aged ≥ 60 years also completed the Subjective Cognitive Decline Questionnaire (MiCog/SuCog). Associations were assessed via bivariate correlation and multiple linear regression analyses. Results: Age was independently associated with higher PTA4 thresholds in both ears (right: B = 0.60 dB HL per year, 95% CI 0.47-0.73; left: B = 0.61 dB HL per year, 95% CI 0.48-0.74; p < 0.001). SSQ12 scores correlated with PTA (right ear ρ = -0.532) and age (ρ = -0.283; both p < 0.001) and were lower in noise-exposed participants after adjusting for PTA, age, sex and tinnitus (B = -1.005, 95% CI -1.565 to -0.446, p < 0.001). In the cognitive subgroup, right-ear PTA showed an unadjusted correlation with MiCog (ρ = 0.332, p = 0.010); in the adjusted model, neither PTA nor any other predictor was independently associated with MiCog (PTA: B = 0.095, 95% CI -0.075 to 0.264, p = 0.266). No significant association was found between MiCog and the SSQ12 total score (Pearson r = -0.166, p = 0.204; Spearman ρ = -0.241, p = 0.064). Conclusions: Audiometric thresholds, self-reported hearing quality, and cognitive screening capture partially distinct, interrelated dimensions of auditory function. Self-reported measures revealed noise-related difficulties undetected by audiometry. These findings support incorporating patient- and informant-reported outcomes alongside audiometry to support a more comprehensive, patient-centered approach to hearing and cognitive care.
SN  - 2039-4330
SN  - 2039-4349
ER  -