Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 4 min ago
Peer-reviewedCC BYJournal of Magnetic Resonance Imaging

Fast myocardial T₁ mapping using shortened inversion recovery based schemes

Abstract

Background Myocardial T1 mapping shows promise for assessment of cardiomyopathies. Most myocardial T1 mapping techniques, such as modified Look–Locker inversion recovery (MOLLI), generate one T1 map per breath‐held acquisition (9–17 heartbeats), which prolongs multislice protocols and may be unsuitable for patients with breath‐holding difficulties. Purpose To develop and characterize novel shortened inversion recovery based T1 mapping schemes of 2–5 heartbeats. Study Type Prospective. Population/Phantom Numerical simulations, agarose/NiCl2 phantom, 16 healthy volunteers, and 24 patients. Field Strength/Sequence 1.5T/MOLLI. Assessment All shortened T1 mapping schemes were characterized and compared with a conventional MOLLI scheme (5‐(3)‐3) in terms of accuracy, precision, spatial variability, and repeatability. Statistical Tests Kruskal–Wallis, Wilcoxon rank sum tests, analysis of variance, Student's t‐tests, Bland–Altman analysis, and Pearson correlation analysis. Results All shortened schemes provided limited T1 time variations (≤2% for T1 times ≤1200 msec) and limited penalty of precision (by a factor of ~1.4–1.5) when compared with MOLLI in numerical simulations. In phantom, differences between all schemes in terms of accuracy, spatial variability, and repeatability did not reach statistical significance (P > 0.71). In healthy volunteers, there were no statistically significant differences between all schemes in terms of native T1 times and repeatability for myocardium (P = 0.21 and P = 0.87, respectively) and blood (P = 0.79 and P = 0.41, respectively). All shortened schemes led to a limited increase of spatial variability for native myocardial T1 mapping with respect to MOLLI (by a factor of 1.2) (P < 0.0001). In both healthy volunteers and patients, the two‐heartbeat scheme and MOLLI led to highly linearly correlated T1 times (correlation coefficients ≥0.83). Data Conclusion The proposed two‐heartbeat T1 mapping scheme yields a 5‐fold acceleration compared with MOLLI, with highly linearly correlated T1 times, no significant difference of repeatability, and limited spatial variability penalty at 1.5T. This approach may enable myocardial T1 mapping in patients with severe breath‐holding difficulties and reduce the examination time of multislice protocols. Level of Evidence: 1 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2019;50:641–654.

Related

  1. Hyperintense Vessels on Acute Stroke Fluid-Attenuated Inversion Recovery Imaging
    Bastian Cheng, Martin Ebinger, Anna Kufner +13
    StrokePeer-reviewedLicence not stated62 citedNeuroscienceHAL
  2. Free‐breathing multislice native myocardial T 1 mapping using the slice‐interleaved T 1 (STONE) sequence
    Sebastian Weingärtner, Sébastien Roujol, Mehmet Akçakaya +2
    Magnetic Resonance in MedicinePeer-reviewedLicence not statedFull text106 citedSystems & synthetic biologyHAL
  3. The CXCL12γ/ACKR3 Axis Is a Critical Determinant of Myocardial Angiogenesis and Functional Recovery After Infarction
    Vincent Duval, Morgane Aubert, Alina Ramazanova +14
    JACC : Basic to Translational SciencePeer-reviewedCC BY-NC-ND 4.0Full textCell biologyCardiovascular medicineHAL
  4. Follow-up availability and the robustness of immune transcriptomic recovery after myocardial infarction
    L. You, G. Zhang, Z. Peng +3
    bioRxivPreprintCC BYFull textBioinformatics & computational biologybioRxiv
  5. Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping
    Sébastien Roujol, Tamer Basha, Sebastian Weingärtner +4
    Journal of Cardiovascular Magnetic ResonancePeer-reviewedCC BYFull text26 citedSystems & synthetic biologyHAL
BibTeX
@article{huang2026fast,
  title = {{Fast myocardial T₁ mapping using shortened inversion recovery based schemes}},
  author = {Li Huang and Radhouene Neji and Muhummad Sohaib Nazir and John Whitaker and Fiona Reid and Filippo Bosio and Amedeo Chiribiri and Reza Razavi and Sébastien Roujol},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  month = oct,
  doi = {10.1002/jmri.26649},
  url = {https://hal.science/hal-05796036v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Fast myocardial T₁ mapping using shortened inversion recovery based schemes
AU  - Li Huang
AU  - Radhouene Neji
AU  - Muhummad Sohaib Nazir
AU  - John Whitaker
AU  - Fiona Reid
AU  - Filippo Bosio
AU  - Amedeo Chiribiri
AU  - Reza Razavi
AU  - Sébastien Roujol
PY  - 2026
DA  - 2026/10/12
JO  - Journal of Magnetic Resonance Imaging
DO  - 10.1002/jmri.26649
UR  - https://hal.science/hal-05796036v1
AB  - Background Myocardial T1 mapping shows promise for assessment of cardiomyopathies. Most myocardial T1 mapping techniques, such as modified Look–Locker inversion recovery (MOLLI), generate one T1 map per breath‐held acquisition (9–17 heartbeats), which prolongs multislice protocols and may be unsuitable for patients with breath‐holding difficulties. Purpose To develop and characterize novel shortened inversion recovery based T1 mapping schemes of 2–5 heartbeats. Study Type Prospective. Population/Phantom Numerical simulations, agarose/NiCl2 phantom, 16 healthy volunteers, and 24 patients. Field Strength/Sequence 1.5T/MOLLI. Assessment All shortened T1 mapping schemes were characterized and compared with a conventional MOLLI scheme (5‐(3)‐3) in terms of accuracy, precision, spatial variability, and repeatability. Statistical Tests Kruskal–Wallis, Wilcoxon rank sum tests, analysis of variance, Student's t‐tests, Bland–Altman analysis, and Pearson correlation analysis. Results All shortened schemes provided limited T1 time variations (≤2% for T1 times ≤1200 msec) and limited penalty of precision (by a factor of ~1.4–1.5) when compared with MOLLI in numerical simulations. In phantom, differences between all schemes in terms of accuracy, spatial variability, and repeatability did not reach statistical significance (P > 0.71). In healthy volunteers, there were no statistically significant differences between all schemes in terms of native T1 times and repeatability for myocardium (P = 0.21 and P = 0.87, respectively) and blood (P = 0.79 and P = 0.41, respectively). All shortened schemes led to a limited increase of spatial variability for native myocardial T1 mapping with respect to MOLLI (by a factor of 1.2) (P < 0.0001). In both healthy volunteers and patients, the two‐heartbeat scheme and MOLLI led to highly linearly correlated T1 times (correlation coefficients ≥0.83). Data Conclusion The proposed two‐heartbeat T1 mapping scheme yields a 5‐fold acceleration compared with MOLLI, with highly linearly correlated T1 times, no significant difference of repeatability, and limited spatial variability penalty at 1.5T. This approach may enable myocardial T1 mapping in patients with severe breath‐holding difficulties and reduce the examination time of multislice protocols. Level of Evidence: 1 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2019;50:641–654.
SN  - 1053-1807
SN  - 1522-2586
ER  -