Pelvic Floor Muscle Reactivity Measured Using M‐Mode Ultrasonography in Males With Post‐Prostatectomy Incontinence
7 affiliations
- 1Pelvic Floor Center, Kochi Medical School Kochi University Nankoku Japan
- 2Department of Physical Therapy Yawatahama City General Hospital Yawatahama Japan
- 3Center of Medical Information Science, Kochi Medical School Kochi University Nankoku Japan
- 4Department of Occupational Therapy Yawatahama City General Hospital Yawatahama Japan
- 5Department of Urology Yawatahama City General Hospital Yawatahama Japan
- 6Department of Urology, Kochi Medical School Kochi University Nankoku Japan
- 7Department of Pharmacology, Kochi Medical School Kochi University Nankoku Japan
Abstract
Objectives: To characterize changes in M‐mode measures of bladder base movement during supervised pelvic floor rehabilitation and their associations with urinary incontinence severity.
Methods: This retrospective cohort included 69 males with urinary incontinence after radical prostatectomy who received supervised pelvic floor muscle training with ultrasound biofeedback. Within‐participant changes, correlations, and regression analyses were performed. Firth logistic regression for continence included age, baseline pad weight, time from surgery to training, and baseline elevation time.
Results: Median pad weight decreased from 247 (interquartile range, 64–684) to 40 (0–195) g/day, and elevation time shortened from 0.31 (0.24–0.45) to 0.20 (0.18–0.23) s (both p < 0.001; r = 0.83). Elevation speed increased (p < 0.001; r = 0.68), whereas elevation length did not change (p = 0.972; r = 0.00). Continence was achieved by 26 participants (37.7%). Pad weight correlated with elevation time at baseline (Spearman's ρ = 0.348; p = 0.003) and final assessment (Spearman's ρ = 0.417; p < 0.001). No statistically significant association was detected between baseline elevation time and continence in the main Firth model (adjusted odds ratio per 0.1‐s increase, 0.954; 95% confidence interval, 0.633–1.349; p = 0.797).
Conclusions: Lower pad weight, shorter elevation time, and greater elevation speed co‐occurred during supervised rehabilitation. Elevation time was associated with incontinence severity cross‐sectionally. No statistically significant association was detected between baseline elevation time and continence in the main Firth model. Prospective validation is required before clinical use.
Related
- Risk prediction for 12-month post-prostatectomy urinary incontinence to support survivorship care: development and same-center temporal validation of a perioperative model
- Real-time artificial intelligence-assisted assessment in a home-based pelvic floor muscle training device for pelvic organ prolapse and stress urinary incontinence: A single-center prospective study
- Functional Magnetic Stimulation for Post-Prostatectomy Urinary Incontinence: A Retrospective Cohort Study of Real-World Outcomes and Factors Associated with Treatment Response.
- Changes in nurses’ knowledge and observed clinical practice following a competency-based educational intervention in pelvic organ prolapse and urinary incontinence care: a quasi-experimental single-group pretest–posttest study
- The effect of pelvic floor muscle exercise, progressive muscle relaxation exercise, and their combined application on comfort in women with stress urinary incontinence: a four-arm randomized controlled trial
BibTeX
@article{ide2026pelvic,
title = {{Pelvic Floor Muscle Reactivity Measured Using M‐Mode Ultrasonography in Males With Post‐Prostatectomy Incontinence}},
author = {Yukimasa Ide and Nobutaka Shimizu and Yuki Hyohdoh and Rio Ninomiya and Tomoko Ogawa and Rie Yoshimura and Yoshitaka Kurano and Satoshi Fukata and Hajime Takeda and Motoaki Saito and Keiji Inoue},
journal = {International Journal of Urology},
year = {2026},
month = nov,
doi = {10.1111/iju.70722},
url = {https://doi.org/10.1111/iju.70722},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Pelvic Floor Muscle Reactivity Measured Using M‐Mode Ultrasonography in Males With Post‐Prostatectomy Incontinence
AU - Yukimasa Ide
AU - Nobutaka Shimizu
AU - Yuki Hyohdoh
AU - Rio Ninomiya
AU - Tomoko Ogawa
AU - Rie Yoshimura
AU - Yoshitaka Kurano
AU - Satoshi Fukata
AU - Hajime Takeda
AU - Motoaki Saito
AU - Keiji Inoue
PY - 2026
DA - 2026/11/16
JO - International Journal of Urology
DO - 10.1111/iju.70722
UR - https://doi.org/10.1111/iju.70722
AB - Objectives: To characterize changes in M‐mode measures of bladder base movement during supervised pelvic floor rehabilitation and their associations with urinary incontinence severity. Methods: This retrospective cohort included 69 males with urinary incontinence after radical prostatectomy who received supervised pelvic floor muscle training with ultrasound biofeedback. Within‐participant changes, correlations, and regression analyses were performed. Firth logistic regression for continence included age, baseline pad weight, time from surgery to training, and baseline elevation time. Results: Median pad weight decreased from 247 (interquartile range, 64–684) to 40 (0–195) g/day, and elevation time shortened from 0.31 (0.24–0.45) to 0.20 (0.18–0.23) s (both p < 0.001; r = 0.83). Elevation speed increased (p < 0.001; r = 0.68), whereas elevation length did not change (p = 0.972; r = 0.00). Continence was achieved by 26 participants (37.7%). Pad weight correlated with elevation time at baseline (Spearman's ρ = 0.348; p = 0.003) and final assessment (Spearman's ρ = 0.417; p < 0.001). No statistically significant association was detected between baseline elevation time and continence in the main Firth model (adjusted odds ratio per 0.1‐s increase, 0.954; 95% confidence interval, 0.633–1.349; p = 0.797). Conclusions: Lower pad weight, shorter elevation time, and greater elevation speed co‐occurred during supervised rehabilitation. Elevation time was associated with incontinence severity cross‐sectionally. No statistically significant association was detected between baseline elevation time and continence in the main Firth model. Prospective validation is required before clinical use.
SN - 0919-8172
SN - 1442-2042
ER -