Diagnostic performance with sensitivity/specificity optimized computer-aided detection to detect common abnormalities in chest radiography
- 1Artificial Intelligence in Diagnostic Radiology, The University of Osaka Graduate School of Medicine, Suita, Japan
- 2Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, The University of Osaka, 2-2 Yamadaoka, Suita, 5650871 Osaka Japan
- 3Department of Radiology, Keio University Graduate School of Medicine, Tokyo, Japan
Abstract
Purpose: To evaluate how two fixed computer-aided detection (CAD) operating modes—sensitivity-optimized (SE-CAD) and specificity-optimized (SP-CAD)—affect radiologists’ diagnostic performance in chest radiography (CXR). Previous studies have focused on the performance of standalone CAD at different threshold settings. However, in clinical practice, CAD is commonly used as a decision-support tool for radiologists. This study aimed to evaluate the impact of different CAD threshold settings on radiologists’ diagnostic performance.
Materials and methods: This retrospective single-center diagnostic accuracy study evaluated posteroanterior or anteroposterior CXRs acquired between 2013 and 2023, interpreted with and without AI assistance, using CT as the reference standard. Six radiologists (three residents / three board-certified) read all cases four times over two sessions: first without CAD, then with either SE_CAD or SP_CAD, and after 1-month washout period, second session using the alternative CAD.
Results: 375 patients (mean age, 65 ± 15 years; 170 women) were included. The dataset comprised 139 cases with pulmonary opacities (nodules / masses / consolidations), 119 with pleural effusion, 29 with pneumothorax, and 161 normal cases, including overlaps. SP_CAD-assisted readings showed higher specificity than SE_CAD-assisted for pulmonary opacities (p < 0.001). Sensitivity did not differ significantly between SE_CAD and SP_CAD assistance. For pulmonary opacities, CAD-assisted reading showed higher sensitivity (both CAD: p < 0.001) but lower specificity (SE_CAD: p = 0.006; SP_CAD: p = 0.03) than unassisted reading. For pleural effusion, CAD-assisted improved sensitivity (SE_CAD: p < 0.001; SP_CAD: p = 0.02) and specificity (both CAD: p < 0.001) than unassisted reading. For pneumothorax, SE_CAD assistance did not significantly affect sensitivity but decreased specificity, whereas SP_CAD assistance improved sensitivity without significantly affecting specificity.
Conclusion: The specificity-prioritized CAD showed higher specificity than the sensitivity-prioritized CAD, without a significant reduction in sensitivity. These findings suggest that different CAD operating points can influence radiologists’ diagnostic performance.
Secondary abstract: We compared radiologist performance using sensitivity-optimized and specificity-optimized computer-aided detection (CAD). Different predefined CAD operating points influenced radiologist performance, resulting in differences in specificity for nodules/masses/consolidations. Our results show that different preset decision thresholds within the same AI model can influence diagnostic performance in AI-assisted radiograph interpretation.
Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s11604-026-02053-y.
Related
- Diagnostic accuracy of urine test strips for CSF analysis: high sensitivity in detecting blood, low sensitivity but high specificity in detecting inflammation
- Diagnostic Performance of Different AI Tools for Chest Radiography: A CT-Anchored Per-Abnormality Analysis in a Tertiary Referral Center.
- Clinical Diagnosis Versus Plain Radiography for Diabetic Foot Osteomyelitis: A Prospective Study of Diagnostic Agreement in a Resource‐Limited Settings
- Beyond overall accuracy: subgroup performance and threshold calibration of AI-assisted chest radiography for equity-oriented pulmonary tuberculosis screening.
- Diagnostic accuracy of cone beam computed tomography in the detection of furcation perforations: an in vitro comparison with periapical radiography and micro-computed tomography
BibTeX
@article{tomiyama2026diagnostic,
title = {{Diagnostic performance with sensitivity/specificity optimized computer-aided detection to detect common abnormalities in chest radiography}},
author = {Miyuki Tomiyama and Masahiro Yanagawa and Tsubasa Yoshida and Kuniaki Ohara and Chiaki Masuda and Keisuke Ninomiya and Shuhei Doi and Atsushi Nakamoto and Masatoshi Hori and Masahiro Hashimoto and Noriyuki Tomiyama},
journal = {Japanese Journal of Radiology},
year = {2026},
month = aug,
doi = {10.1007/s11604-026-02053-y},
url = {https://doi.org/10.1007/s11604-026-02053-y},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Diagnostic performance with sensitivity/specificity optimized computer-aided detection to detect common abnormalities in chest radiography
AU - Miyuki Tomiyama
AU - Masahiro Yanagawa
AU - Tsubasa Yoshida
AU - Kuniaki Ohara
AU - Chiaki Masuda
AU - Keisuke Ninomiya
AU - Shuhei Doi
AU - Atsushi Nakamoto
AU - Masatoshi Hori
AU - Masahiro Hashimoto
AU - Noriyuki Tomiyama
PY - 2026
DA - 2026/08/03
JO - Japanese Journal of Radiology
DO - 10.1007/s11604-026-02053-y
UR - https://doi.org/10.1007/s11604-026-02053-y
AB - Purpose: To evaluate how two fixed computer-aided detection (CAD) operating modes—sensitivity-optimized (SE-CAD) and specificity-optimized (SP-CAD)—affect radiologists’ diagnostic performance in chest radiography (CXR). Previous studies have focused on the performance of standalone CAD at different threshold settings. However, in clinical practice, CAD is commonly used as a decision-support tool for radiologists. This study aimed to evaluate the impact of different CAD threshold settings on radiologists’ diagnostic performance. Materials and methods: This retrospective single-center diagnostic accuracy study evaluated posteroanterior or anteroposterior CXRs acquired between 2013 and 2023, interpreted with and without AI assistance, using CT as the reference standard. Six radiologists (three residents / three board-certified) read all cases four times over two sessions: first without CAD, then with either SE_CAD or SP_CAD, and after 1-month washout period, second session using the alternative CAD. Results: 375 patients (mean age, 65 ± 15 years; 170 women) were included. The dataset comprised 139 cases with pulmonary opacities (nodules / masses / consolidations), 119 with pleural effusion, 29 with pneumothorax, and 161 normal cases, including overlaps. SP_CAD-assisted readings showed higher specificity than SE_CAD-assisted for pulmonary opacities (p < 0.001). Sensitivity did not differ significantly between SE_CAD and SP_CAD assistance. For pulmonary opacities, CAD-assisted reading showed higher sensitivity (both CAD: p < 0.001) but lower specificity (SE_CAD: p = 0.006; SP_CAD: p = 0.03) than unassisted reading. For pleural effusion, CAD-assisted improved sensitivity (SE_CAD: p < 0.001; SP_CAD: p = 0.02) and specificity (both CAD: p < 0.001) than unassisted reading. For pneumothorax, SE_CAD assistance did not significantly affect sensitivity but decreased specificity, whereas SP_CAD assistance improved sensitivity without significantly affecting specificity. Conclusion: The specificity-prioritized CAD showed higher specificity than the sensitivity-prioritized CAD, without a significant reduction in sensitivity. These findings suggest that different CAD operating points can influence radiologists’ diagnostic performance. Secondary abstract: We compared radiologist performance using sensitivity-optimized and specificity-optimized computer-aided detection (CAD). Different predefined CAD operating points influenced radiologist performance, resulting in differences in specificity for nodules/masses/consolidations. Our results show that different preset decision thresholds within the same AI model can influence diagnostic performance in AI-assisted radiograph interpretation. Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s11604-026-02053-y.
SN - 1867-1071
SN - 1867-108X
ER -