Effect of Intensity Discretization on Radiomic Features in En Face EDI-OCT of Choroidal Nevi

  1. 1Nova Medical School, Universidade Nova de Lisboa, Lisboa, Portugal

Abstract

Background/Objectives: Intensity discretization influences radiomic measurements, but its effects in optical coherence tomography (OCT) of choroidal lesions remain insufficiently characterized. We evaluated fixed bin width (FBW) and fixed bin number (FBN) strategies with different parameters to inform discretization choices for en face enhanced-depth imaging OCT (EDI-OCT) of stable choroidal nevi. Methods: Ninety-three original-domain radiomic features were extracted from 64 eyes across 11 discretization settings (FBW 2 - 64; FBN 8 - 64). We assessed feature values, eye rankings, observer reproducibility, slab-depth dependence, redundancy, and feature-set overlap. Primary absolute-agreement intraclass correlation coefficients (ICCs) used per-eye feature values averaged across six numeric slabs. Histogram entropy and an approximate co-occurrence sampling-density proxy characterized the discretized intensity representation. Results: Seventy-seven features depended on discretization. Median occupied gray levels decreased with increasing bin width from 54 at FBW 2 to five at FBW 25. Eye rankings were similar between neighboring settings (median Spearman {rho} 0.97 - 0.99), but less concordant in selected FBW - FBN comparisons. Median observer ICCs ranged from 0.84 to 0.91, without clear evidence of differences between settings. Feature sets overlapped less after redundancy reduction. FBW 4 and FBN 32 provided intermediate gray-level resolution and sampling-density proxies, retaining at least 16 occupied gray levels in approximately 99% and 100% of observations, respectively. Conclusions: Intensity discretization substantially alters radiomic texture values, eye rankings, and feature selection. Observer reproducibility alone is insufficient to guide discretization choice. Intensity representation, gray-level compression, and slab depth should also be considered. FBW 4 and FBN 32 emerged as exploratory candidate settings within the evaluated pipeline. External validation and assessment of clinical utility remain necessary.

Related

  1. Postprocessing of Structural En Face OCT Images of the Choroidal Haller Layer for Quantitative Assessment: An Exploratory Pilot Study
    Anait S. Khalatyan, Yusef Yusef, Konstantin S. Avetisov +7
    BiomedicinesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. CT radiomic features detect mineral, collagen, and water contributions to cortical bone texture
    Youngjun Lee, Wikum R. Bandara, Peter K. Jalaie +6
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMedical imaging & radiologyCrossref
  3. Evaluation of MRI Radiomic Features as Surrogates of Tumor Immune Status in Breast Cancer: A Pilot Study of MRI-Derived Radiomic Features for Non-Invasive Immune Profiling in Breast Cancer.
    Mimansha Shah, Soaham Kumar, Narendra Kumar +1
    CancersPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  4. Hybrid deep learning and meta learning for Alzheimer disease classification via multimodal radiomic and visual features
    Areej Y. Bayahya, Fares Jammal
    Scientific ReportsPeer-reviewedCC BYFull textPsychiatry & mental healthDOAJ
  5. Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study
    Kwang Ho Yoo, Hyewon Song, Yuhwa Choi
    Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)Peer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@misc{franca2026effect,
  title = {{Effect of Intensity Discretization on Radiomic Features in En Face EDI-OCT of Choroidal Nevi}},
  author = {M. Vila Franca and J. P. Nobre and D. Saraiva and H. R. Pereira and H. D. Ferreira and M. D. Medeiros and M. d. L. Cachulo},
  howpublished = {medRxiv},
  year = {2026},
  month = nov,
  doi = {10.64898/2026.11.01.26367028},
  url = {https://www.medrxiv.org/content/10.64898/2026.11.01.26367028v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Effect of Intensity Discretization on Radiomic Features in En Face EDI-OCT of Choroidal Nevi
AU  - M. Vila Franca
AU  - J. P. Nobre
AU  - D. Saraiva
AU  - H. R. Pereira
AU  - H. D. Ferreira
AU  - M. D. Medeiros
AU  - M. d. L. Cachulo
PY  - 2026
DA  - 2026/11/01
PB  - medRxiv
DO  - 10.64898/2026.11.01.26367028
UR  - https://www.medrxiv.org/content/10.64898/2026.11.01.26367028v1
AB  - Background/Objectives: Intensity discretization influences radiomic measurements, but its effects in optical coherence tomography (OCT) of choroidal lesions remain insufficiently characterized. We evaluated fixed bin width (FBW) and fixed bin number (FBN) strategies with different parameters to inform discretization choices for en face enhanced-depth imaging OCT (EDI-OCT) of stable choroidal nevi. Methods: Ninety-three original-domain radiomic features were extracted from 64 eyes across 11 discretization settings (FBW 2 - 64; FBN 8 - 64). We assessed feature values, eye rankings, observer reproducibility, slab-depth dependence, redundancy, and feature-set overlap. Primary absolute-agreement intraclass correlation coefficients (ICCs) used per-eye feature values averaged across six numeric slabs. Histogram entropy and an approximate co-occurrence sampling-density proxy characterized the discretized intensity representation. Results: Seventy-seven features depended on discretization. Median occupied gray levels decreased with increasing bin width from 54 at FBW 2 to five at FBW 25. Eye rankings were similar between neighboring settings (median Spearman {rho} 0.97 - 0.99), but less concordant in selected FBW - FBN comparisons. Median observer ICCs ranged from 0.84 to 0.91, without clear evidence of differences between settings. Feature sets overlapped less after redundancy reduction. FBW 4 and FBN 32 provided intermediate gray-level resolution and sampling-density proxies, retaining at least 16 occupied gray levels in approximately 99% and 100% of observations, respectively. Conclusions: Intensity discretization substantially alters radiomic texture values, eye rankings, and feature selection. Observer reproducibility alone is insufficient to guide discretization choice. Intensity representation, gray-level compression, and slab depth should also be considered. FBW 4 and FBN 32 emerged as exploratory candidate settings within the evaluated pipeline. External validation and assessment of clinical utility remain necessary.