Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 5 min ago
PreprintCC BY-NC-ND 4.0arXiv

Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons

Abstract

Range uncertainties remain a major limitation to the full clinical exploitation of proton therapy, motivating reliable in-vivo range-verification techniques. This work presents an experimental investigation of a hybrid Prompt-Gamma Imaging (PGI)--Positron-Emission Tomography (PET) concept at the isochronous cyclotron of the West German Proton Therapy Centre under clinically representative pencil-beam-scanning conditions. Because this accelerator delivers a quasi-continuous beam, a pulsed shoot-and-step structure was imposed to mimic the interruptions associated with clinical energy-layer switching. This enabled PGI during irradiation and PET and delayed Compton imaging during beam-off intervals within the same sequence. Four two-plane Compton cameras were arranged in a co-planar cross-shaped geometry around the beam isocenter. Polyethylene phantoms were irradiated with 100~MeV protons at known positions along the beam axis. Their positions were estimated from reconstructed one-dimensional profiles using supervised machine-learning models trained exclusively on Monte Carlo simulations. PET achieved the best performance, with a root-mean-square deviation of 0.8~mm, followed by PGI with 1.6~mm. Delayed Compton imaging based on e+ annihilation photons and 10C* decays yielded 2.4~mm and 3.8~mm, respectively. PET retained good performance down to 1% of the original event statistics, whereas PGI became increasingly statistics-limited. These results demonstrate the complementary strengths of hybrid PGI--PET and support its development towards millimetre-scale proton-range verification under clinically relevant irradiation conditions.

Related

  1. Imaging performance of a Single-Plane Readout Compton Camera
    Om Prakash Dash, Tomislav Bokulić, Damir Bosnar +1
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  2. Positron Emission Tomography with quantum-entangled Compton events: first imaging results at clinically relevant activities
    Mihael Makek, Ana Marija Kožuljević, Tomislav Bokulić +4
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationBiological & medical physicsarXiv
  3. Real-Time Requirements and Transferability in Compton Imaging: From the Detector Chain to the Application
    F. Albiol, Elena Larrea Estrelles, Salvador Tortajada +4
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationBiological & medical physicsarXiv
  4. Emittance preservation under multifaceted CSR effects in isochronous deflection structures for multikiloampere bunches
    Xiuji Chen, Si Chen, Duan Gu +1
    Physical Review Accelerators and BeamsPeer-reviewedCC BYFull textNuclear physicsDOAJ
  5. Correlation Imaging via Hybrid Entanglement between Microwave Photons and Surface Acoustic Wave Phonons
    Yu-Yuan Chen, Ling-An Wu, Yu-xi Liu
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationQuantum physics & quantum informationarXiv
BibTeX
@misc{balibreacorrea2026towards,
  title = {{Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons}},
  author = {Javier Balibrea-Correa and V. Babiano-Suarez and J. Lerendegui-Marco and P. Torres-Sánchez and I. Ladarescu and M. Pallàs and B. Brusasco and J. Wulff and C. Bäumer and A. Tarifeño-Saldivia and C. Domingo-Pardo},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.25993},
  eprint = {2609.25993},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.25993},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - UNPB
TI  - Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons
AU  - Javier Balibrea-Correa
AU  - V. Babiano-Suarez
AU  - J. Lerendegui-Marco
AU  - P. Torres-Sánchez
AU  - I. Ladarescu
AU  - M. Pallàs
AU  - B. Brusasco
AU  - J. Wulff
AU  - C. Bäumer
AU  - A. Tarifeño-Saldivia
AU  - C. Domingo-Pardo
PY  - 2026
DA  - 2026/09/22
PB  - arXiv
DO  - 10.48550/arxiv.2609.25993
UR  - https://arxiv.org/abs/2609.25993
AB  - Range uncertainties remain a major limitation to the full clinical exploitation of proton therapy, motivating reliable in-vivo range-verification techniques. This work presents an experimental investigation of a hybrid Prompt-Gamma Imaging (PGI)--Positron-Emission Tomography (PET) concept at the isochronous cyclotron of the West German Proton Therapy Centre under clinically representative pencil-beam-scanning conditions. Because this accelerator delivers a quasi-continuous beam, a pulsed shoot-and-step structure was imposed to mimic the interruptions associated with clinical energy-layer switching. This enabled PGI during irradiation and PET and delayed Compton imaging during beam-off intervals within the same sequence. Four two-plane Compton cameras were arranged in a co-planar cross-shaped geometry around the beam isocenter. Polyethylene phantoms were irradiated with 100~MeV protons at known positions along the beam axis. Their positions were estimated from reconstructed one-dimensional profiles using supervised machine-learning models trained exclusively on Monte Carlo simulations. PET achieved the best performance, with a root-mean-square deviation of 0.8~mm, followed by PGI with 1.6~mm. Delayed Compton imaging based on e^+ annihilation photons and ^10C^* decays yielded 2.4~mm and 3.8~mm, respectively. PET retained good performance down to 1% of the original event statistics, whereas PGI became increasingly statistics-limited. These results demonstrate the complementary strengths of hybrid PGI--PET and support its development towards millimetre-scale proton-range verification under clinically relevant irradiation conditions.
ER  -