Arthroscopic tie‐knot versus suture bridge fixation for anterior cruciate ligament tibial avulsion fractures: A 5‐year comparative study
4 affiliations
- 1General Hospital of Ningxia Medical University Ningxia China.
- 2Ningxia Medical University Ningxia China.
- 3Hainan District People's Hospital Inner China.
- 4WuHai People's Hospital Inner China.
Abstract
Purpose
To compare perioperative outcomes, radiographic healing, recovery trajectories and 5-year clinical outcomes after arthroscopic tie-knot (TK) and suture bridge (SB) fixation of anterior cruciate ligament (ACL) tibial avulsion fractures.Methods
This single-center retrospective comparative cohort study identified 146 adults treated between 19 December 2017, and 31 August 2020. After clinical exclusions and incomplete 5-year follow-up, 90 patients formed the complete-case cohort (TK, n = 42; SB, n = 48). Longitudinal visual analog scale (VAS), International Knee Documentation Committee (IKDC), Lysholm, range-of-motion (ROM) and KT-1000 side-to-side laxity outcomes were analyzed using covariate-adjusted generalized estimating equations (GEEs). Holm correction was applied across the five global group-by-time tests and within each outcome for postoperative contrasts.Results
Operative time was 12.47 min longer with SB fixation (95% confidence interval [CI], 8.58-16.36; p < 0.001), whereas the recorded radiographic-healing interval was 0.76 weeks shorter (95% CI, 0.14-1.38 weeks shorter; p = 0.017). After Holm correction across outcome domains, group-by-time interactions remained significant for International Knee Documentation Committee (IKDC) (adjusted p = 0.013) and Lysholm (adjusted p = 0.048), but not VAS (p = 0.069), ROM (p = 0.069), or KT-1000 (p = 0.266). Exploratory within-outcome contrasts showed small 1-month differences in VAS, IKDC, Lysholm, and ROM; no between-group difference persisted from 6 months to 5 years.Conclusion
Both fixation strategies were associated with favorable 5-year knee function and stability. SB fixation required longer operative time and was associated with a slightly shorter recorded healing interval and small early differences of uncertain clinical importance. The nonrandomized design and residual confounding preclude claims of technique superiority.Level of evidence
Level III, retrospective comparative cohort study.
Related
- Arthroscopic 3-Point Suture-Bridge Fixation for Posterior Cruciate Ligament Tibial Avulsion Fractures via Triple Bone Tunnels.
- Arthroscopic Quadrupled Semitendinosus Autograft Anterior Cruciate Ligament Reconstruction With Suspensory Fixation
- Arthroscopic Pull-Out Suture vs. Open Screw Fixation for ACL Tibial Avulsion Fractures: A Comparative Study
- A Comparative Study of Functional Outcomes Following Arthroscopic Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon versus Peroneus Longus Tendon Autograft
- Functional Outcome in Arthroscopic Anterior Cruciate Ligament Reconstruction Using an Autologous Quadrupled Hamstring Tendon Versus Peroneus Longus Tendon Graft: A Comparative Study
BibTeX
@article{liu2026arthroscopic,
title = {{Arthroscopic tie‐knot versus suture bridge fixation for anterior cruciate ligament tibial avulsion fractures: A 5‐year comparative study}},
author = {Zhe Liu and Jing Guo and Haoxin Li and Haifeng Yuan},
journal = {Journal of experimental orthopaedics},
year = {2026},
month = oct,
doi = {10.1002/jeo2.71008},
url = {https://europepmc.org/article/PMC/PMC13795104},
note = {CC BY},
}
RIS
TY - JOUR
TI - Arthroscopic tie‐knot versus suture bridge fixation for anterior cruciate ligament tibial avulsion fractures: A 5‐year comparative study
AU - Zhe Liu
AU - Jing Guo
AU - Haoxin Li
AU - Haifeng Yuan
PY - 2026
DA - 2026/10/01
JO - Journal of experimental orthopaedics
DO - 10.1002/jeo2.71008
UR - https://europepmc.org/article/PMC/PMC13795104
AB - Purpose To compare perioperative outcomes, radiographic healing, recovery trajectories and 5-year clinical outcomes after arthroscopic tie-knot (TK) and suture bridge (SB) fixation of anterior cruciate ligament (ACL) tibial avulsion fractures.Methods This single-center retrospective comparative cohort study identified 146 adults treated between 19 December 2017, and 31 August 2020. After clinical exclusions and incomplete 5-year follow-up, 90 patients formed the complete-case cohort (TK, n = 42; SB, n = 48). Longitudinal visual analog scale (VAS), International Knee Documentation Committee (IKDC), Lysholm, range-of-motion (ROM) and KT-1000 side-to-side laxity outcomes were analyzed using covariate-adjusted generalized estimating equations (GEEs). Holm correction was applied across the five global group-by-time tests and within each outcome for postoperative contrasts.Results Operative time was 12.47 min longer with SB fixation (95% confidence interval [CI], 8.58-16.36; p < 0.001), whereas the recorded radiographic-healing interval was 0.76 weeks shorter (95% CI, 0.14-1.38 weeks shorter; p = 0.017). After Holm correction across outcome domains, group-by-time interactions remained significant for International Knee Documentation Committee (IKDC) (adjusted p = 0.013) and Lysholm (adjusted p = 0.048), but not VAS (p = 0.069), ROM (p = 0.069), or KT-1000 (p = 0.266). Exploratory within-outcome contrasts showed small 1-month differences in VAS, IKDC, Lysholm, and ROM; no between-group difference persisted from 6 months to 5 years.Conclusion Both fixation strategies were associated with favorable 5-year knee function and stability. SB fixation required longer operative time and was associated with a slightly shorter recorded healing interval and small early differences of uncertain clinical importance. The nonrandomized design and residual confounding preclude claims of technique superiority.Level of evidence Level III, retrospective comparative cohort study.
SN - 2197-1153
ER -