Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BYPLOS One

Validation and optimisation of wearable accelerometer data pre-processing for digital measure implementation and development

  1. 1Department of Public Health and Sport Sciences, University of Exeter, Exeter, United Kingdom.
  2. 2ActivInsights Limited, Kimbolton, Cambridge, United Kingdom.
  3. 3Stoat Group Limited, Devon, United Kingdom.

Abstract

The increasing use of accelerometers as digital health technologies in clinical trials and clinical care is driving the need for data processing to meet medical standards. The aim of this study was to create and test a modular pipeline for the pre-processing of high-resolution accelerometry that assures the quality, transparency and traceability of digital measures from sensor-level data. The objective is for the pipeline to be a foundational layer in the development, implementation and comparison of measures. The study developed the open GENEAcore package to meet the requirements of regulators, verifying the engineering implementation and analytically validating outputs against reference datasets. Early stages included the optimisation of calibration and non-wear detection. Data-driven detection of behavioural transitions was then validated to give direct bout outputs without the need to identify rules for epoch aggregation and interruptions. The utility for measure development was shown by comparing two algorithms for the characterisation of activity intensity in both the epoch and bout paradigms. Non-wear was detected with a balanced accuracy of 92.3% and the commonly used 13mg acceleration standard deviation threshold was empirically validated with a sensitivity analysis for the first time. The detection of transitions proved reliable with 99% detected, on average, within 2 seconds of their occurrence to give a mean expected event duration of 68.6s from a log-normal distribution. The different activity intensity algorithms were more than 99% concordant during movement but their outputs diverged in low movement conditions. Importantly, variable duration bouts created 31% higher daily activity durations compared to 1-second epochs. This evaluation of pre-processing steps has confirmed the attention to detail required to create robust and reproducible results for later clinical validation where small changes in an algorithm or its implementation may have clinically meaningful consequences.

Related

  1. A pipeline with pre-processing options to detect behaviour from accelerometer data using Machine Learning tested on dairy goats
    Sarah Mauny, Joon Kwon, Nicolas N.C. Friggens +2
    Peer Community JournalPeer-reviewedCC BY 4.0Full text10 citedGeneral biologyHAL
  2. IMU-based upper limb kinematics validation: sensor fusion optimisation, sensor-to-segment alignment, and joint angle accuracy.
    A. Fabre, G. Kerr, P. Pivonka +1
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  3. Optimizing accelerometer implementation in a gerotherapeutic trial: Feasibility, adherence, and operational insights of ABLE
    Jessica K. Lu, Weilan Wang, Yi Ern Chew +3
    PLOS Digital HealthPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationGenetics & genomicsPLOS
  4. Regulating Next-Generation Implantable Brain-Computer Interfaces: Recommendations for Ethical Development and Implementation
    Renée A. Sirbu, Jessica Morley, T. Schröder +5
    NeuroethicsPeer-reviewedLicence not stated10 citedNeuroscienceOpenAlex
  5. Maternal Anxiety During Pregnancy and Offspring Information Processing Across Development: A Theory-Guided Predictive-Processing Reappraisal of Two Longitudinal Cohorts
    Bea R. H. Van den Bergh, Martin G. Frasch
    arXivPreprintCC BY-NC-ND 4.0Full textBioinformatics & computational biologyNeurosciencearXiv
BibTeX
@article{langford2026validation,
  title = {{Validation and optimisation of wearable accelerometer data pre-processing for digital measure implementation and development}},
  author = {Joss Langford and Jia Ying Chua and Ian Long and Alan C Williams and Melvyn Hillsdon},
  journal = {PLOS One},
  year = {2026},
  month = oct,
  doi = {10.1371/journal.pone.0346458},
  url = {https://doi.org/10.1371/journal.pone.0346458},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Validation and optimisation of wearable accelerometer data pre-processing for digital measure implementation and development
AU  - Joss Langford
AU  - Jia Ying Chua
AU  - Ian Long
AU  - Alan C Williams
AU  - Melvyn Hillsdon
PY  - 2026
DA  - 2026/10/21
JO  - PLOS One
DO  - 10.1371/journal.pone.0346458
UR  - https://doi.org/10.1371/journal.pone.0346458
AB  - The increasing use of accelerometers as digital health technologies in clinical trials and clinical care is driving the need for data processing to meet medical standards. The aim of this study was to create and test a modular pipeline for the pre-processing of high-resolution accelerometry that assures the quality, transparency and traceability of digital measures from sensor-level data. The objective is for the pipeline to be a foundational layer in the development, implementation and comparison of measures. The study developed the open GENEAcore package to meet the requirements of regulators, verifying the engineering implementation and analytically validating outputs against reference datasets. Early stages included the optimisation of calibration and non-wear detection. Data-driven detection of behavioural transitions was then validated to give direct bout outputs without the need to identify rules for epoch aggregation and interruptions. The utility for measure development was shown by comparing two algorithms for the characterisation of activity intensity in both the epoch and bout paradigms. Non-wear was detected with a balanced accuracy of 92.3% and the commonly used 13mg acceleration standard deviation threshold was empirically validated with a sensitivity analysis for the first time. The detection of transitions proved reliable with 99% detected, on average, within 2 seconds of their occurrence to give a mean expected event duration of 68.6s from a log-normal distribution. The different activity intensity algorithms were more than 99% concordant during movement but their outputs diverged in low movement conditions. Importantly, variable duration bouts created 31% higher daily activity durations compared to 1-second epochs. This evaluation of pre-processing steps has confirmed the attention to detail required to create robust and reproducible results for later clinical validation where small changes in an algorithm or its implementation may have clinically meaningful consequences.
SN  - 1932-6203
ER  -