Comparison of Passive Head Lift and Combined Chin Lift/Jaw Thrust Maneuvers for Transesophageal Echocardiograph (TEE) Probe Insertion
- 1Department of Anaesthesiology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India
Abstract
Background:: Transesophageal echocardiography (TEE) is widely used in cardiac and non-cardiac surgeries for real-time cardiac monitoring. However, insertion of the TEE probe under general anesthesia can be challenging.
Objectives:: Aim of the study was to compare the first pass success rate of two maneuvers for TEE probe insertion—passive head lift versus combined chin lift/jaw thrust. Secondary objectives included the number of attempts, time taken for insertion, hemodynamic response, and incidence of oral cavity or mucosal injuries.
Methods:: A prospective, observational study was conducted on 70 adult patients scheduled for elective cardiac surgery under general anesthesia. Eligible patients were assigned to one of two maneuvers: passive head lift (Group A) or combined chin lift/jaw thrust (Group B). The TEE probe insertion was performed by an anesthesiologist experienced in TEE, with another observer recording number of attempts, insertion time, hemodynamic changes at specific time periods, and presence of oral injuries. Statistical analysis included the independent t-test, Wilcoxon-Mann-Whitney U test, Chi-squared test, and Fisher’s Exact t test.
Results:: The first pass success rate was significantly higher in the passive head lift group (91.4%) compared to the chin lift/jaw thrust group (60%) (P = 0.002). The number of attempts and time taken for insertion were also significantly lower in Group A (P = 0.004 and P = 0.01, respectively). No significant differences in hemodynamic changes or mucosal injuries were observed.
Conclusion:: The passive head lift maneuver is superior to the combined chin lift/jaw thrust maneuver for TEE probe insertion, with higher success on first attempt, shorter insertion time, and require only a single operator.
Related
- Automatic transesophageal echocardiographic evaluation of patients with mitral valve prolapse: comparison with patients without structural cardiac chamber remodeling (an exploratory study)
- Anatomical spread of the novel transversus abdominis–rectus abdominis aponeurotic (TARAA) block: a cadaveric comparison with lateral transversus abdominis plane (TAP) and combined TAP-rectus sheath blocks
- Vagal maneuvers and pharmacological cardioversion in stable PSVT: A systematic review with implications for emergency nursing practice
- Complex cardiac schwannoma surgery: Navigation with perioperative 3-dimensional transesophageal echocardiography
- When 2D is not enough: 3D transesophageal echocardiography revealing a multifenestrated atrial septal defect.
BibTeX
@article{ananthanarayanan2026comparison,
title = {{Comparison of Passive Head Lift and Combined Chin Lift/Jaw Thrust Maneuvers for Transesophageal Echocardiograph (TEE) Probe Insertion}},
author = {Akshaya Ananthanarayanan and Vijaya Kumara},
journal = {Annals of Cardiac Anaesthesia},
year = {2026},
month = oct,
doi = {10.4103/aca.aca_89_26},
url = {https://doi.org/10.4103/aca.aca_89_26},
note = {CC BY-NC-SA 4.0},
}
RIS
TY - JOUR
TI - Comparison of Passive Head Lift and Combined Chin Lift/Jaw Thrust Maneuvers for Transesophageal Echocardiograph (TEE) Probe Insertion
AU - Akshaya Ananthanarayanan
AU - Vijaya Kumara
PY - 2026
DA - 2026/10/12
JO - Annals of Cardiac Anaesthesia
DO - 10.4103/aca.aca_89_26
UR - https://doi.org/10.4103/aca.aca_89_26
AB - Background:: Transesophageal echocardiography (TEE) is widely used in cardiac and non-cardiac surgeries for real-time cardiac monitoring. However, insertion of the TEE probe under general anesthesia can be challenging. Objectives:: Aim of the study was to compare the first pass success rate of two maneuvers for TEE probe insertion—passive head lift versus combined chin lift/jaw thrust. Secondary objectives included the number of attempts, time taken for insertion, hemodynamic response, and incidence of oral cavity or mucosal injuries. Methods:: A prospective, observational study was conducted on 70 adult patients scheduled for elective cardiac surgery under general anesthesia. Eligible patients were assigned to one of two maneuvers: passive head lift (Group A) or combined chin lift/jaw thrust (Group B). The TEE probe insertion was performed by an anesthesiologist experienced in TEE, with another observer recording number of attempts, insertion time, hemodynamic changes at specific time periods, and presence of oral injuries. Statistical analysis included the independent t-test, Wilcoxon-Mann-Whitney U test, Chi-squared test, and Fisher’s Exact t test. Results:: The first pass success rate was significantly higher in the passive head lift group (91.4%) compared to the chin lift/jaw thrust group (60%) (P = 0.002). The number of attempts and time taken for insertion were also significantly lower in Group A (P = 0.004 and P = 0.01, respectively). No significant differences in hemodynamic changes or mucosal injuries were observed. Conclusion:: The passive head lift maneuver is superior to the combined chin lift/jaw thrust maneuver for TEE probe insertion, with higher success on first attempt, shorter insertion time, and require only a single operator.
SN - 0971-9784
SN - 0974-5181
ER -