Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 59 min ago
PreprintarXiv licencearXiv

Shielding design and construction for the XINGZHI cold neutron triple-axis spectrometer: integrating velocity selector, S-bender polarizer, and neutron guide

Abstract

The optimized design and construction of shielding for the velocity selector, S-bender polarizer, and neutron guide in the XINGZHI cold neutron triple-axis spectrometer have been successfully completed. The challenge of limited space available for XINGZHI has been met by a compact shielding structure, developed through Monte Carlo simulations and realized by purpose-built mechanical design, thus leaving more floor space for the spectrometer. An innovative lead-antimony alloy ensures rigidity for self-support, while optimized tolerances for gaps between mating blocks meet safety, machinability, and mounting requirements. Additionally, a long-distance alignment method has been implemented, facilitating the alternating installation of the neutron guide and shielding system. After six years of operation, this structure has been verified to meet radiation safety standards while maximizing available space, marking a significant advancement in neutron instrumentation in China and offering valuable methodologies for future development.

Related

  1. A nonequilibrium-capturing unified gas-kinetic scheme I: discrete orthogonal basis construction and expansion on velocity space
    Hongyu Liu, Kun Xu
    arXivPreprintarXiv licenceFull textNumerical analysis & scientific computingComputational physicsarXiv
  2. Role of chirality in the polarizer-filter dichotomy in nonmagnetic junctions
    Sergei Urazhdin
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  3. Chirped-pulse millimetre-wave spectrometer for the 140–180 GHz region
    C. Lauzin, H. Schmutz, J. A. Agner +1
    Molecular PhysicsPeer-reviewedLicence not stated7 citedPhysical chemistryGeneral physicsHAL
  4. Inverse-designed integrated computational spectrometer with sub-ångström resolution
    Kai Wang, Enge Zhang, Luyang Liu +4
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  5. Design and characteristics of a cavity-enhanced Fourier-transform spectrometer based on a supercontinuum source
    A. Libert, X. Urbain, B. Fabre +2
    Review of Scientific InstrumentsPeer-reviewedLicence not stated7 citedPhysical chemistryGeneral physicsHAL
BibTeX
@misc{zhang2026shielding,
  title = {{Shielding design and construction for the XINGZHI cold neutron triple-axis spectrometer: integrating velocity selector, S-bender polarizer, and neutron guide}},
  author = {Hongxia Zhang and Daye Xu and Florian Grünauer and Jinchen Wang and Yuntao Liu and Juanjuan Liu and Peng Cheng and Wei Bao},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.41288},
  eprint = {2610.41288},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.41288},
}
RIS
TY  - UNPB
TI  - Shielding design and construction for the XINGZHI cold neutron triple-axis spectrometer: integrating velocity selector, S-bender polarizer, and neutron guide
AU  - Hongxia Zhang
AU  - Daye Xu
AU  - Florian Grünauer
AU  - Jinchen Wang
AU  - Yuntao Liu
AU  - Juanjuan Liu
AU  - Peng Cheng
AU  - Wei Bao
PY  - 2026
DA  - 2026/10/30
PB  - arXiv
DO  - 10.48550/arxiv.2610.41288
UR  - https://arxiv.org/abs/2610.41288
AB  - The optimized design and construction of shielding for the velocity selector, S-bender polarizer, and neutron guide in the XINGZHI cold neutron triple-axis spectrometer have been successfully completed. The challenge of limited space available for XINGZHI has been met by a compact shielding structure, developed through Monte Carlo simulations and realized by purpose-built mechanical design, thus leaving more floor space for the spectrometer. An innovative lead-antimony alloy ensures rigidity for self-support, while optimized tolerances for gaps between mating blocks meet safety, machinability, and mounting requirements. Additionally, a long-distance alignment method has been implemented, facilitating the alternating installation of the neutron guide and shielding system. After six years of operation, this structure has been verified to meet radiation safety standards while maximizing available space, marking a significant advancement in neutron instrumentation in China and offering valuable methodologies for future development.
ER  -