Computational biomechanics of capsulolabral stress and elongation in Hill–Sachs bone defect: a finite element method aimed at patient-specific prediction of glenohumeral instability
- 1Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Zacatenco, Ciudad de México, México
- 2Universidad Tecnológica de Durango, Departamento Académico de Mecatrónica y Energías Renovables, Durango, México
Abstract
Hill–Sachs is a compression fracture of the posterolateral humeral head that occurs in up to 93% of patients with recurrent anterior glenohumeral instability. Although previous research has primarily focused on the osseous defect, joint stability depends on a complex interaction between the soft tissue biomechanics (bone, cartilage, labrum, capsule, and ligaments). The mechanical interaction between the Hill–Sachs defect and joint soft tissues remains insufficiently characterized. This study used finite-element method analysis to evaluate the biomechanical response of the capsulolabral complex to humeral head defects of different sizes in the abduction and external rotation position. A patient-specific computational model of the glenohumeral joint was reconstructed from computed tomography; based on data from a female volunteer. Five defect sizes were simulated: 0% (healthy for reference), 6%, 9%, 31%, and 44% of the humeral head. Stress distributions in the labrum and elongation of the articular capsule were analyzed using ANSYS Workbench®. The model represents the changes present in the corresponding bone and cartilage. Therefore, the reported outcomes are limited to the biomechanical parameters of stress and elongation of the soft tissues derived from the numerical simulation. The healthy model served as the baseline for comparison. In the labrum, models with bone defects showed lower stress values than the healthy model, indicating reduced functional disruption of the suction-cup effect. Regional analysis revealed localized compression in the superior labrum, suggesting tissue pinching, and areas close to zero stress indicated a loss of uniform distribution. For the articular capsule, elongation remained stable up to a 31% bone defect; beyond this threshold, elongation increased, which was interpreted as capsular laxity. The values presented correspond to a trend seen exclusively in the numerical simulation. This study establishes a foundation for patient-specific simulations to predict the risk of instability and guide surgical decision-making. From Bankart repair to remplissage or bone augmentation procedures, this approach supports a more personalized method for managing shoulder instability.
Related
- SCOPE (Scapular Corrections for Posterior Escape) for posterior glenohumeral instability: technique of posterior acromial corrective osteotomy with optional glenoid corrective osteotomy
- Failure Analysis in Patients With Recurrent Anterior Shoulder Instability After Primary Arthroscopic Capsulolabral Repair
- Intersession reliability and magnitude of change of isokinetic testing of the glenohumeral rotators in overhead athletes with unilateral shoulder anterior instability
- Side‐Step Cutting Foot Biomechanics and Intrinsic Foot Muscle Sizes in People With Chronic Ankle Instability
- Indications for Isolated Arthroscopic Bankart Repair in the Adolescent Shoulder May Be Limited: Bipolar Bone Loss and Low Distance to Dislocation Found Commonly in an Adolescent Population With Glenohumeral Instability
BibTeX
@article{suarezhernandez2026computational,
title = {{Computational biomechanics of capsulolabral stress and elongation in Hill–Sachs bone defect: a finite element method aimed at patient-specific prediction of glenohumeral instability}},
author = {Maria de la Luz Suarez-Hernandez and Guillermo Urriolagoitia-Sosa and Beatriz Romero-Ángeles and Francisco Carrasco-Hernández and Jacobo Martines-Reyes and Gabriela Ramirez-Sanchez and Felix de Jesus Mar-Luna and Ivan Alejandro Lopez-Zumaran and Manuel Nazario Rocha-Martinez},
journal = {Frontiers in Surgery},
year = {2026},
month = nov,
doi = {10.3389/fsurg.2026.1931532},
url = {https://doi.org/10.3389/fsurg.2026.1931532},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Computational biomechanics of capsulolabral stress and elongation in Hill–Sachs bone defect: a finite element method aimed at patient-specific prediction of glenohumeral instability
AU - Maria de la Luz Suarez-Hernandez
AU - Guillermo Urriolagoitia-Sosa
AU - Beatriz Romero-Ángeles
AU - Francisco Carrasco-Hernández
AU - Jacobo Martines-Reyes
AU - Gabriela Ramirez-Sanchez
AU - Felix de Jesus Mar-Luna
AU - Ivan Alejandro Lopez-Zumaran
AU - Manuel Nazario Rocha-Martinez
PY - 2026
DA - 2026/11/06
JO - Frontiers in Surgery
DO - 10.3389/fsurg.2026.1931532
UR - https://doi.org/10.3389/fsurg.2026.1931532
AB - Hill–Sachs is a compression fracture of the posterolateral humeral head that occurs in up to 93% of patients with recurrent anterior glenohumeral instability. Although previous research has primarily focused on the osseous defect, joint stability depends on a complex interaction between the soft tissue biomechanics (bone, cartilage, labrum, capsule, and ligaments). The mechanical interaction between the Hill–Sachs defect and joint soft tissues remains insufficiently characterized. This study used finite-element method analysis to evaluate the biomechanical response of the capsulolabral complex to humeral head defects of different sizes in the abduction and external rotation position. A patient-specific computational model of the glenohumeral joint was reconstructed from computed tomography; based on data from a female volunteer. Five defect sizes were simulated: 0% (healthy for reference), 6%, 9%, 31%, and 44% of the humeral head. Stress distributions in the labrum and elongation of the articular capsule were analyzed using ANSYS Workbench®. The model represents the changes present in the corresponding bone and cartilage. Therefore, the reported outcomes are limited to the biomechanical parameters of stress and elongation of the soft tissues derived from the numerical simulation. The healthy model served as the baseline for comparison. In the labrum, models with bone defects showed lower stress values than the healthy model, indicating reduced functional disruption of the suction-cup effect. Regional analysis revealed localized compression in the superior labrum, suggesting tissue pinching, and areas close to zero stress indicated a loss of uniform distribution. For the articular capsule, elongation remained stable up to a 31% bone defect; beyond this threshold, elongation increased, which was interpreted as capsular laxity. The values presented correspond to a trend seen exclusively in the numerical simulation. This study establishes a foundation for patient-specific simulations to predict the risk of instability and guide surgical decision-making. From Bankart repair to remplissage or bone augmentation procedures, this approach supports a more personalized method for managing shoulder instability.
SN - 2296-875X
ER -