Skip to content
DraconiticResearch
Search Sources API
185,139 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BYBMC medical education

Simulation-based ultrasound-guided lumbar puncture training using a flipped classroom: a single-arm pilot programme evaluation.

6 affiliations
  1. 1School of Medicine, Chung Shan Medical University, Taichung, Taiwan, ROC.
  2. 2Emergency Department, Chung Shan Medical University Hospital, Taichung, Taiwan, ROC.
  3. 3Research Assistant Center, Show Chwan Memorial Hospital, Changhua, Taiwan, ROC.
  4. 4Department of Nursing, Central Taiwan University of Science and Technology, Taichung, Taiwan, ROC.
  5. 5Institute for Research into Cancer of the Digestive System (IRCAD) - Taiwan and Asian Institute of TeleSurgery, Show Chwan Health Care System, Changhua, Taiwan, ROC. [email protected].
  6. 6Department of Emergency Medicine, Chang Bing Show Chwan Memorial Hospital, No. 6 Lugong Road. Lukang Zhen, Changhua, Taiwan, ROC. [email protected].

Abstract

Background

Traditional landmark-guided lumbar puncture (LP) has high failure rates among novice emergency medicine (EM) clinicians. While ultrasound guidance improves success, structured training models remain limited and expensive. We evaluated a cost-effective, simulation-based flipped classroom curriculum for teaching ultrasound-guided LP to EM residents and trainees.Methods

We developed a high-fidelity, custom 3D-printed spinal simulator costing approximately $40 USD per unit. The curriculum utilized a flipped classroom model combining online theoretical modules with hands-on, deliberate practice.Results

Twenty-two participants (9 EM residents, 13 PGY trainees) completed the training programme; paired landmark-versus-ultrasound OSCE data were available for the seven residents who completed both phases. Among EM residents with paired data (n = 7), the ultrasound-guided phase OSCE completion rate was 100%, compared to 43% during the earlier landmark phase (a large but statistically non-significant difference, p = 0.125, McNemar's exact test). The ultrasound-guided phase was associated with higher rubric-rated performance scores and overall ratings (nominally significant, uncorrected for multiple comparisons); needle passes (median 7 vs. 12) and procedure times were also lower but did not reach statistical significance in this small paired sample. Both groups reported significantly lower procedural stress with ultrasound guidance, with a smaller, non-significant increase in confidence.Conclusions

A flipped classroom curriculum utilizing a low-cost, 3D-printed simulator is a feasible and well-received educational innovation for teaching ultrasound-guided LP, with encouraging but preliminary performance findings for EM residents that require confirmation in controlled studies.

Related

  1. A Multicomponent Simulation-Based Program Incorporating Ultrasound for Lumbar Puncture Training in Medical Students: A Randomized Controlled Educational Trial
    Amirah Alatawi, Hassan Moria, Talal Turki Alqubali +5
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Non-Ultrasound-Guided Versus Ultrasound-Guided Femoral Venous Puncture in the Interventional Pulmonary Embolism Era: Does Ultrasound Guidance Improve Safety and Feasibility?
    Abdelrahman Elhakim, Desouki Abdelatti, Mohamed Elhakim +6
    Reviews in cardiovascular medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. Pilot Mixed-Methods Evaluation of Simulation-Based Focused Cardiac Ultrasound Teaching for Final-Year Medical Students
    Vishnuga Uthayamohan, Katie Allen, Olalekan Ogundana +1
    CureusPeer-reviewedCC BYFull textCardiovascular medicineEurope PMCPMC
  4. Which classroom anxiety experience should teachers target first? A network-simulation study of foreign language classroom anxiety and enjoyment
    Xia Yu, Qian Zhou
    Frontiers in PsychiatryPeer-reviewedCC BY 4.0Full textPsychiatry & mental healthCrossrefEurope PMCPMC
  5. Technical feasibility of an angle-free ultrasound-assisted approach for challenging lumbar puncture in complex spinal anatomy: a two-patient case series
    Xuan Wang, Yijun Luo, Xiaolong Zhang +4
    BMC AnesthesiologyPeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJ
BibTeX
@article{huang2026simulationbased,
  title = {{Simulation-based ultrasound-guided lumbar puncture training using a flipped classroom: a single-arm pilot programme evaluation.}},
  author = {Chao-Yen Huang and Sai-Wai Ho and Po-Ming Chen and Chia-Ching Chen},
  journal = {BMC medical education},
  year = {2026},
  month = aug,
  doi = {10.1186/s12909-026-10070-8},
  url = {https://europepmc.org/article/MED/42958232},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Simulation-based ultrasound-guided lumbar puncture training using a flipped classroom: a single-arm pilot programme evaluation.
AU  - Chao-Yen Huang
AU  - Sai-Wai Ho
AU  - Po-Ming Chen
AU  - Chia-Ching Chen
PY  - 2026
DA  - 2026/08/01
JO  - BMC medical education
DO  - 10.1186/s12909-026-10070-8
UR  - https://europepmc.org/article/MED/42958232
AB  - Background  Traditional landmark-guided lumbar puncture (LP) has high failure rates among novice emergency medicine (EM) clinicians. While ultrasound guidance improves success, structured training models remain limited and expensive. We evaluated a cost-effective, simulation-based flipped classroom curriculum for teaching ultrasound-guided LP to EM residents and trainees.Methods  We developed a high-fidelity, custom 3D-printed spinal simulator costing approximately $40 USD per unit. The curriculum utilized a flipped classroom model combining online theoretical modules with hands-on, deliberate practice.Results  Twenty-two participants (9 EM residents, 13 PGY trainees) completed the training programme; paired landmark-versus-ultrasound OSCE data were available for the seven residents who completed both phases. Among EM residents with paired data (n = 7), the ultrasound-guided phase OSCE completion rate was 100%, compared to 43% during the earlier landmark phase (a large but statistically non-significant difference, p = 0.125, McNemar's exact test). The ultrasound-guided phase was associated with higher rubric-rated performance scores and overall ratings (nominally significant, uncorrected for multiple comparisons); needle passes (median 7 vs. 12) and procedure times were also lower but did not reach statistical significance in this small paired sample. Both groups reported significantly lower procedural stress with ultrasound guidance, with a smaller, non-significant increase in confidence.Conclusions  A flipped classroom curriculum utilizing a low-cost, 3D-printed simulator is a feasible and well-received educational innovation for teaching ultrasound-guided LP, with encouraging but preliminary performance findings for EM residents that require confirmation in controlled studies.
SN  - 1472-6920
ER  -