Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 14 min ago
Peer-reviewedCC BY-NCInternational journal of women's health

Remote Patient Monitoring for Type 2 Diabetes Management During Pregnancy: A Feasibility Study and Outcomes Analysis within a Medicaid Population.

4 affiliations
  1. 1Institute for Digital Health and Innovation, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
  2. 2Department of Pharmacy Practice, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
  3. 3College of Medicine, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
  4. 4Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, AR, USA.

Abstract

Purpose

Type 2 Diabetes Mellitus (T2DM) during pregnancy is a growing public health concern due to its increasing prevalence and association with adverse maternal and neonatal health outcomes. This study assessed the feasibility of using a Remote Patient Monitoring (RPM) iGlucose glucometer to manage T2DM during pregnancy among a cohort of Medicaid women and compared clinical outcomes among RPM users and women using a standard glucometer.Patients and methods

Thirty-three pregnant women utilizing Medicaid with T2DM were provided an RPM iGlucose device. Participants completed a pre-post survey and semi-structured interview. To assess clinical outcomes, we created a Connected Device Use group, consisting of participants who used the iGlucose device or a continuous glucose monitoring device, and a Standard Paper Log group, consisting of individuals who used a standard glucometer.Results

A significant decrease between pre-post scores was seen for Appraisal of Diabetes (p=0.0046) and Perceived Stress (p=0.0296). Treatment Self-Efficacy (p=0.0030) and General Self-Efficacy (p=0.0129) significantly increased with iGlucose device use. Overall, perceptions of the iGlucose device were positive with advantages including automatic upload of glucose readings, ease of use, increased self-efficacy, perceived better care, and decreased stress and anxiety. No significant difference in clinical outcomes was seen between groups.Conclusion

By automatically uploading glucose readings, remote patient monitoring significantly lightens the burden for people with chronic conditions. This technology provides healthcare clinicians with accurate, real-time data which can lead to better informed and proactive care decisions.

Related

  1. Pregnancy Complicated by Citrin Deficiency and Gestational Diabetes Mellitus: Perioperative Metabolic Management and Postoperative Analgesic Challenges Following Caesarean Delivery
    Ei Ei Phyo Naing, Ei Mon Mon Kyaw
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Optimising the prevention, detection and management of diabetes distress in adults with type 1 diabetes: D-stress feasibility study protocol
    Clara Fabian-Therond, Shalini Ahuja, Iliatha Papachristou Nadal +22
    BMJ OpenPeer-reviewedLicence not statedGeneral medicineCrossref
  3. Management of alloimmunization in pregnancy: Screening, monitoring, and treatment; the Dutch quality standard
    R M van 't Oever, P G Scheffer, J M Middeldorp +15
    Pregnancy (Hoboken, N.J.)Peer-reviewedCC BYFull textGeneral medicineEurope PMCEurope PMC
  4. Construction of a management model based on traditional Chinese medicine comprehensive health management for a high-risk gestational diabetes mellitus population and its impact on postpartum diabetes
    Yuqin Niu, Hongmei Liu, Dandan Sun +1
    American Journal of Translational ResearchPeer-reviewedLicence not statedFull textObstetrics, gynaecology & paediatricsPMC
  5. The effect of the centering pregnancy model on diabetes self- management, self-efficacy, pregnancy experience, and perinatal outcomes in women with diabetes: a randomized controlled trial.
    Mahsa Maghalian, Fatemeh Abbasalizadeh, Sakineh Mohammad-Alizadeh-Charandabi +2
    Reproductive healthPeer-reviewedCC BY-NC-NDFull textObstetrics, gynaecology & paediatricsEurope PMCPMC
BibTeX
@article{jones2026remote,
  title = {{Remote Patient Monitoring for Type 2 Diabetes Management During Pregnancy: A Feasibility Study and Outcomes Analysis within a Medicaid Population.}},
  author = {Crystal D Jones and Cheng Peng and Rebecca D Jones and Karina Leal Vargas and Amalie Gunn and Nafisa Dajani and Hari Eswaran},
  journal = {International journal of women's health},
  year = {2026},
  month = nov,
  doi = {10.2147/ijwh.s613685},
  url = {https://europepmc.org/article/MED/43017520},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Remote Patient Monitoring for Type 2 Diabetes Management During Pregnancy: A Feasibility Study and Outcomes Analysis within a Medicaid Population.
AU  - Crystal D Jones
AU  - Cheng Peng
AU  - Rebecca D Jones
AU  - Karina Leal Vargas
AU  - Amalie Gunn
AU  - Nafisa Dajani
AU  - Hari Eswaran
PY  - 2026
DA  - 2026/11/07
JO  - International journal of women's health
DO  - 10.2147/ijwh.s613685
UR  - https://europepmc.org/article/MED/43017520
AB  - Purpose  Type 2 Diabetes Mellitus (T2DM) during pregnancy is a growing public health concern due to its increasing prevalence and association with adverse maternal and neonatal health outcomes. This study assessed the feasibility of using a Remote Patient Monitoring (RPM) iGlucose glucometer to manage T2DM during pregnancy among a cohort of Medicaid women and compared clinical outcomes among RPM users and women using a standard glucometer.Patients and methods  Thirty-three pregnant women utilizing Medicaid with T2DM were provided an RPM iGlucose device. Participants completed a pre-post survey and semi-structured interview. To assess clinical outcomes, we created a Connected Device Use group, consisting of participants who used the iGlucose device or a continuous glucose monitoring device, and a Standard Paper Log group, consisting of individuals who used a standard glucometer.Results  A significant decrease between pre-post scores was seen for Appraisal of Diabetes (p=0.0046) and Perceived Stress (p=0.0296). Treatment Self-Efficacy (p=0.0030) and General Self-Efficacy (p=0.0129) significantly increased with iGlucose device use. Overall, perceptions of the iGlucose device were positive with advantages including automatic upload of glucose readings, ease of use, increased self-efficacy, perceived better care, and decreased stress and anxiety. No significant difference in clinical outcomes was seen between groups.Conclusion  By automatically uploading glucose readings, remote patient monitoring significantly lightens the burden for people with chronic conditions. This technology provides healthcare clinicians with accurate, real-time data which can lead to better informed and proactive care decisions.
SN  - 1179-1411
ER  -