Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BYJournal of cardiovascular development and disease

False-Positive Scar Control in Scribble-Supervised LGE-CMR Segmentation Using an Asymmetric Intensity Prior.

5 affiliations
  1. 1School of Medical Imaging, Fujian Medical University, Fuzhou 350122, China.
  2. 2Department of Biomedical Engineering, College of Design and Engineering, National University of Singapore, Singapore 117583, Singapore.
  3. 3College of Integrative Medicine, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, China.
  4. 4Network Technology Center, Fujian Cancer Hospital, Fuzhou 350014, China.
  5. 5College of Computer and Data Science, Fuzhou University, Fuzhou 350108, China.

Abstract

Background: Scribble-supervised LGE-CMR segmentation can overestimate myocardial scar. Methods: We introduced an asymmetric intensity prior that penalizes predicted scar darker than a scribble-derived reference. We evaluated 36 patient-disjoint test cases using reference myocardium-guided crops and performed separate reference-free central-crop and automatic-myocardial-wall analyses. The main prior-specific comparison matched the 2.5D backbone with and without the prior across three seeds. Results: On the pre-cropped images, mean Dice increased from 0.5328±0.0108 to 0.5472±0.0060, while recall fell from 0.6924 to 0.6399. The predicted-to-reference scar ratio fell from 1.6796±0.1834 to 1.4039±0.1389, and absolute scar-volume error fell from 21.09±5.27 to 14.08±2.47 mL on the common crop grid. However, restriction to the reference myocardial wall increased absolute percent-LV-scar error from 5.55±1.14 to 6.58±0.99 percentage points. With additional healthy-myocardium background points (seed 2022), the matched prior model reduced Pred/GT from 1.5789 to 1.1500 but Dice fell from 0.5441 to 0.5366. With one fixed-rule reference-free central crop and retraining (seed 2022), Dice was 0.4892 without and 0.5047 with the prior. In a paired automatic-wall analysis, the prior did not improve three-seed wall-restricted burden error (6.14 versus 8.16 percentage points). Conclusions: The prior reduced full-output overestimation on the pre-cropped images, but did not improve intramyocardial burden agreement or retain a Dice advantage in the single-seed healthy-background sensitivity analysis. Its effects depend on localization and wall quality and require independent prospective reference-free evaluation.

Related

  1. SAM3-SemiSkin: Parameter-Efficient Adaptation with Heterogeneous Decoders for Semi-Supervised Dermoscopic and Brain-MRI Segmentation
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Asymmetric encoder-decoder U-net with hybrid attention and residual dilated convolution for brain tumor segmentation
    Xiaoshuai Cao, Xige Song, Jincan Zhang +2
    Frontiers in NeurosciencePeer-reviewedCC BY 4.0Full textNeurologyFrontiersCrossrefDOAJEurope PMC+1
  3. A novel morphological assessment approach for abdominal aortic aneurysms: automated segmentation and measurement using a semi-supervised deep learning algorithm
    Guangkuo Wang, Jingyi Zeng, Min Li +3
    Frontiers in cardiovascular medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMCCrossref
  4. Beyond Segmentation: Coronary Artery Calcium Scoring with Frozen Self-Supervised CT Features.
    Mahmut S Gokmen, Evan Damron, Caroline Leach +9
    Journal of imagingPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  5. HSV-Net: hybrid state-space and self-supervised vision fusion with progressive contour learning for CT pulmonary nodule segmentation.
    Liang Cheng, Xinsheng Wan
    Frontiers in oncologyPeer-reviewedCC BYFull textOncologyEurope PMCCrossref
BibTeX
@article{lan2026falsepositive,
  title = {{False-Positive Scar Control in Scribble-Supervised LGE-CMR Segmentation Using an Asymmetric Intensity Prior.}},
  author = {Xin Lan and Xinchen Xie and Jinwei Dong and Chenming Zhao and Qitong Zhang and Wangbin Ding and Shimei Fu},
  journal = {Journal of cardiovascular development and disease},
  year = {2026},
  month = nov,
  doi = {10.3390/jcdd13110605},
  url = {https://europepmc.org/article/MED/43083112},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - False-Positive Scar Control in Scribble-Supervised LGE-CMR Segmentation Using an Asymmetric Intensity Prior.
AU  - Xin Lan
AU  - Xinchen Xie
AU  - Jinwei Dong
AU  - Chenming Zhao
AU  - Qitong Zhang
AU  - Wangbin Ding
AU  - Shimei Fu
PY  - 2026
DA  - 2026/11/17
JO  - Journal of cardiovascular development and disease
DO  - 10.3390/jcdd13110605
UR  - https://europepmc.org/article/MED/43083112
AB  - Background: Scribble-supervised LGE-CMR segmentation can overestimate myocardial scar. Methods: We introduced an asymmetric intensity prior that penalizes predicted scar darker than a scribble-derived reference. We evaluated 36 patient-disjoint test cases using reference myocardium-guided crops and performed separate reference-free central-crop and automatic-myocardial-wall analyses. The main prior-specific comparison matched the 2.5D backbone with and without the prior across three seeds. Results: On the pre-cropped images, mean Dice increased from 0.5328±0.0108 to 0.5472±0.0060, while recall fell from 0.6924 to 0.6399. The predicted-to-reference scar ratio fell from 1.6796±0.1834 to 1.4039±0.1389, and absolute scar-volume error fell from 21.09±5.27 to 14.08±2.47 mL on the common crop grid. However, restriction to the reference myocardial wall increased absolute percent-LV-scar error from 5.55±1.14 to 6.58±0.99 percentage points. With additional healthy-myocardium background points (seed 2022), the matched prior model reduced Pred/GT from 1.5789 to 1.1500 but Dice fell from 0.5441 to 0.5366. With one fixed-rule reference-free central crop and retraining (seed 2022), Dice was 0.4892 without and 0.5047 with the prior. In a paired automatic-wall analysis, the prior did not improve three-seed wall-restricted burden error (6.14 versus 8.16 percentage points). Conclusions: The prior reduced full-output overestimation on the pre-cropped images, but did not improve intramyocardial burden agreement or retain a Dice advantage in the single-seed healthy-background sensitivity analysis. Its effects depend on localization and wall quality and require independent prospective reference-free evaluation.
SN  - 2308-3425
ER  -