Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 15 min ago
Peer-reviewedCC BY-NC-SAJournal of clinical imaging science

Whole-body low-dose computed tomography image quality and radiation dose in multiple myeloma: A comparison between 64-slice and 128-slice scanners.

  1. 1Department of Radiology, Royal Papworth Hospital, Cambridge, United Kingdom.
  2. 2Department of Radiology, University Hospital Limerick, Limerick, Ireland.

Abstract

Objectives

The objectives of the study are to compare radiation dose and objective image quality between whole- body low-dose computed tomography (WBLDCT) examinations performed on 64-slice and 128-slice scanners in patients with multiple myeloma.Material and methods

This retrospective, single-center observational study included two independent cohorts: 16 patients imaged on a 64-slice scanner, and 16 different patients imaged on a 128-slice scanner. Each scanner used its own clinical protocol. Objective image quality was assessed using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements at the frontal spongy bone, occipital compact bone, and right femoral shaft. Image noise was the standard deviation (SD) of attenuation within an air region of interest. Radiation dose was assessed using dose-length product (DLP), with estimated effective dose calculated using a conversion factor of 0.015 mSv/(mGy•cm). Independent-group comparisons were performed using the Mann- Whitney U test or Welch independent samples t-test, as appropriate. The Holm method was used to adjust the six image-quality comparisons for multiple testing.Results

The 128-slice scanner demonstrated higher SNR and CNR values at all assessed skeletal sites. Improvements were statistically significant at the frontal spongy bone (SNR, p = 0.0019; CNR, p = 0.0027), occipital compact bone (SNR, p = 0.0004; CNR, p = 0.0004), and right femoral shaft (SNR, p = 0.0006; CNR, p = 0.0010), and all six remained significant after Holm adjustment. Mean DLP was significantly lower with the 128-slice scanner than with the 64-slice scanner (328.9 mGy•cm SD 121.0) compared with 638.2 mGy•cm (SD 101.0); mean difference -309.3 mGy•cm (95% confidence interval -389.9--228.7); p < 0.0001), corresponding to a reduction in mean estimated effective dose from 9.57 to 4.93 mSv. Mean volume computed tomography dose index was 4.39 mGy for the 64-slice scanner and 2.26 mGy for the 128-slice scanner. All 64-slice examinations used 140 kV, and 128-slice examinations used 100 or 120 kV.Conclusion

In this cohort, WBLDCT performed on the 128-slice scanner was associated with improved objective image quality and lower radiation dose compared with the 64-slice scanner. These differences cannot be attributed to slice count alone because the two scanners used different protocols, including a lower tube voltage on the 128-slice scanner.

Related

  1. Photon-Counting Computed Tomography Enables Image-Guided Navigation of the Paranasal Sinuses at Ultra-Low Radiation Dose: An Initial Cadaveric Study
    Friederike Bärhold, Tobias Albrecht, Bernhard Hirt +8
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Comparison of Risk Assessment Strategies Recommended by the 2019 and 2024 European Society of Cardiology Guidelines in Patients With Stable Chest Pain: A Coronary Computed Tomography Angiography Study
    Hantao Jiang, Chang Liu, Chao Zhang +4
    Reviews in cardiovascular medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. A Case Report on Multiple Impacted Teeth: A Three-Dimensional Radiological Evaluation by Cone-Beam Computed Tomography
    Karthik Rajaram Mohan, Ramachandra Reddy Gowda Venkatesha, Saramma Mathew Fenn
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Computed tomography findings of a retroperitoneal chronic expanding hematoma with multiple hemangiomas: A case report and literature review
    Takayoshi Shinya, Kanako Yoshida, Takeshi Iwasa +6
    Radiology case reportsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  5. Radiation Dose Reduction in Coronary Computed Tomography Angiography
    Esosa Odigie-Okon, Olushola Ogunleye, Ritika Saxena +6
    JACC Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMedical imaging & radiologyPMC
BibTeX
@article{ahmed2026wholebody,
  title = {{Whole-body low-dose computed tomography image quality and radiation dose in multiple myeloma: A comparison between 64-slice and 128-slice scanners.}},
  author = {Aneeq Ahmed and Patrick Kiely},
  journal = {Journal of clinical imaging science},
  year = {2026},
  month = oct,
  doi = {10.25259/jcis_125_2026},
  url = {https://europepmc.org/article/MED/42974526},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Whole-body low-dose computed tomography image quality and radiation dose in multiple myeloma: A comparison between 64-slice and 128-slice scanners.
AU  - Aneeq Ahmed
AU  - Patrick Kiely
PY  - 2026
DA  - 2026/10/30
JO  - Journal of clinical imaging science
DO  - 10.25259/jcis_125_2026
UR  - https://europepmc.org/article/MED/42974526
AB  - Objectives  The objectives of the study are to compare radiation dose and objective image quality between whole- body low-dose computed tomography (WBLDCT) examinations performed on 64-slice and 128-slice scanners in patients with multiple myeloma.Material and methods  This retrospective, single-center observational study included two independent cohorts: 16 patients imaged on a 64-slice scanner, and 16 different patients imaged on a 128-slice scanner. Each scanner used its own clinical protocol. Objective image quality was assessed using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements at the frontal spongy bone, occipital compact bone, and right femoral shaft. Image noise was the standard deviation (SD) of attenuation within an air region of interest. Radiation dose was assessed using dose-length product (DLP), with estimated effective dose calculated using a conversion factor of 0.015 mSv/(mGy•cm). Independent-group comparisons were performed using the Mann- Whitney U test or Welch independent samples t-test, as appropriate. The Holm method was used to adjust the six image-quality comparisons for multiple testing.Results  The 128-slice scanner demonstrated higher SNR and CNR values at all assessed skeletal sites. Improvements were statistically significant at the frontal spongy bone (SNR, p = 0.0019; CNR, p = 0.0027), occipital compact bone (SNR, p = 0.0004; CNR, p = 0.0004), and right femoral shaft (SNR, p = 0.0006; CNR, p = 0.0010), and all six remained significant after Holm adjustment. Mean DLP was significantly lower with the 128-slice scanner than with the 64-slice scanner (328.9 mGy•cm SD 121.0) compared with 638.2 mGy•cm (SD 101.0); mean difference -309.3 mGy•cm (95% confidence interval -389.9--228.7); p < 0.0001), corresponding to a reduction in mean estimated effective dose from 9.57 to 4.93 mSv. Mean volume computed tomography dose index was 4.39 mGy for the 64-slice scanner and 2.26 mGy for the 128-slice scanner. All 64-slice examinations used 140 kV, and 128-slice examinations used 100 or 120 kV.Conclusion  In this cohort, WBLDCT performed on the 128-slice scanner was associated with improved objective image quality and lower radiation dose compared with the 64-slice scanner. These differences cannot be attributed to slice count alone because the two scanners used different protocols, including a lower tube voltage on the 128-slice scanner.
SN  - 2156-7514
SN  - 2156-5597
ER  -