Skip to content
DraconiticResearch
Search Sources API
194,230 studies31 sourcesUpdated 57 min ago
PreprintCC BY 4.0arXiv

The Position Resolution of a Charged Particle Hodoscope Consisting of Triangular Scintillator Counters

Abstract

Hodoscopes consisting of triangular counters with embedded wavelength shifting fibers are becoming more popular as they are relatively inexpensive, are easily fabricated, need no cooling systems, employ low-cost photodetectors, require only modest voltages, and perhaps most importantly, have good position resolution. Through interpolation of the light yields between adjacent counters, position resolutions that are typically an order of magnitude better than the counter separation can be obtained. Here, after a brief explanation of how the interpolation is done to improve the position resolution, we derive an approximate expressions for the uncertainty in the interpolated x and y positions as a function of the impact position of the charged particle.

Related

  1. Comprehensive study of timing resolution in plastic scintillator detectors with wavelength-shifting fiber and silicon photomultiplier readout
    Haohui Che, Guang Yang
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  2. Intrinsic time resolution of a hexagonal BC404 scintillator: A Monte Carlo study of interaction geometry and optical reflectivity
    C. H. Zepeda-Fernández, L. F. Rebolledo-Herrera, E. Moreno Barbosa
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  3. Energy, time, and position resolution measurements of an array of large tapered LYSO crystals
    O. Beesley, J. Carlton, D. Ding +19
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  4. Analysis of nonlinear wave propagation within architected materials consisting of nonlinear Timoshenko beam structural elements
    Abdallah Wazne, Hilal Reda, Jean-François Ganghoffer +1
    Wave MotionPeer-reviewedLicence not stated3 citedGeneral physicsHAL
  5. Scintillator-integrated microchannel plate photomultiplier tubes for ultrafast timing over keV–GeV energy scales
    Ryosuke Ota, Yuya Onishi, Daehee Lee +8
    ACS photonicsPeer-reviewedLicence not statedFull textApplied physics & instrumentationPMC
BibTeX
@misc{dukes2026position,
  title = {{The Position Resolution of a Charged Particle Hodoscope Consisting of Triangular Scintillator Counters}},
  author = {Edmond Craig Dukes},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.37955},
  eprint = {2610.37955},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.37955},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - The Position Resolution of a Charged Particle Hodoscope Consisting of Triangular Scintillator Counters
AU  - Edmond Craig Dukes
PY  - 2026
DA  - 2026/10/27
PB  - arXiv
DO  - 10.48550/arxiv.2610.37955
UR  - https://arxiv.org/abs/2610.37955
AB  - Hodoscopes consisting of triangular counters with embedded wavelength shifting fibers are becoming more popular as they are relatively inexpensive, are easily fabricated, need no cooling systems, employ low-cost photodetectors, require only modest voltages, and perhaps most importantly, have good position resolution. Through interpolation of the light yields between adjacent counters, position resolutions that are typically an order of magnitude better than the counter separation can be obtained. Here, after a brief explanation of how the interpolation is done to improve the position resolution, we derive an approximate expressions for the uncertainty in the interpolated x and y positions as a function of the impact position of the charged particle.
ER  -