Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 56 min ago
PreprintCC BY 4.0arXiv

The Nancy Grace Roman Space Telescope Wide Field Instrument: Characterization of the Brighter-Fatter Effect in a Roman H4RG-10 Detector using the Talbot Effect

5 more authors

Abstract

The Nancy Grace Roman Space Telescope will conduct several community-driven surveys using its Wide Field Instrument (WFI), which contains 18 Teledyne H4RG-10 near-infrared detectors in the focal plane. Roman's wide area survey to measure weak gravitational lensing places particularly stringent requirements on point spread function (PSF) precision for the WFI. The brighter-fatter effect (BFE) is a nonlinear detector effect caused by the deflection of new charge away from pixels with previously accumulated charge during an exposure. As a result, the PSF measured at the detector depends on the charge contrast between pixels, and therefore the effective PSF for astronomical sources is a function of flux contrast and integration time. We present characterization of the BFE observed in a non-flight H4RG by projecting a grid of bright point sources onto the detector using the Talbot Illuminator at the NASA Goddard Space Flight Center Detector Characterization Lab. We find that the effective area of a pixel decreases by (−2.18±0.04) × 10−6 per electron of charge contrast with its neighbors, corresponding to a measurable increase in the effective PSF size over the course of an exposure. Despite charge migration, the total signal detected in the vicinity of a bright source is roughly conserved. We also analyze flat field statistics for the same detector to measure the total inter-pixel nonlinearity (IPNL), which is dominated by BFE. We present a method to correct BFE in H4RG images using the flat field IPNL results, adapted from an extant optical correction technique. The correction reduces the observed BFE by about a factor of 25 as measured by the effective pixel area change, but there is remaining nonlinearity in the corrected data. We discuss possible sources of residual nonlinearity and suggest avenues to investigate optimal BFE correction in Roman survey images.

Related

  1. Nancy Grace Roman Space Telescope Wide Field Instrument: Grism Saturation Response to Bright Sources during Thermal-Vacuum Testing
    Lipika Chatur, Dana R. Louie, Joshua E. Schlieder +3
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsarXiv
  2. IFU Observations of Comet 3I/ATLAS = C/2025 N1 (ATLAS) using the Hobby-Eberly Telescope with the VIRUS Instrument
    Anita Cochran, Gregory Zeimann, Emmanuel Jehin +2
    arXivPreprintCC BY 4.0Full textGalaxiesPlanetary science & exoplanetsarXiv
  3. The Roman Coronagraph Community Participation Program: corgisim - a simulation suite for the Nancy Grace Roman Space Telescope Coronagraph Instrument
    Jingwen Zhang, Sophie Noiret, Maxwell A. Millar Blanchaer +14
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsPlanetary science & exoplanetsarXiv
  4. IFU Observations of Comet 3I/ATLAS = C/2025 N1 (ATLAS) Using the Hobby–Eberly Telescope with the VIRUS Instrument*
    Anita L. Cochran, Gregory Zeimann, Emmanuel Jehin +2
    The Planetary Science JournalPeer-reviewedCC BY 4.0Full textPlanetary science & exoplanetsCrossref
  5. Concept Study of the Heterodyne Spectroscopy Instrument (HSI) for the Proposed Far-IR Spectroscopy Space Telescope (FIRSST)
    Martina C Wiedner, Andrey Baryshev, Paul Grimes +22
    IEEE Transactions on Terahertz Science and TechnologyPeer-reviewedCC BY 4.0Full text1 citedInstrumentation & methodsGeneral earth scienceHAL
BibTeX
@misc{paine2026nancy,
  title = {{The Nancy Grace Roman Space Telescope Wide Field Instrument: Characterization of the Brighter-Fatter Effect in a Roman H4RG-10 Detector using the Talbot Effect}},
  author = {Jennie Paine and Ami Choi and Christopher Merchant and Timothy D. Brandt and Jeffrey Kruk and Joshua E. Schlieder and Edward J. Wollack and Analia Cillis and Jahmour J. Givans and Robert Hill and Christopher Hirata and Dana R. Louie and Gregory Mosby and Anna Porredon and Bernard J. Rauscher and Maxime J. Rizzo and Rujula Yete},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.03882},
  eprint = {2610.03882},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.03882},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - The Nancy Grace Roman Space Telescope Wide Field Instrument: Characterization of the Brighter-Fatter Effect in a Roman H4RG-10 Detector using the Talbot Effect
AU  - Jennie Paine
AU  - Ami Choi
AU  - Christopher Merchant
AU  - Timothy D. Brandt
AU  - Jeffrey Kruk
AU  - Joshua E. Schlieder
AU  - Edward J. Wollack
AU  - Analia Cillis
AU  - Jahmour J. Givans
AU  - Robert Hill
AU  - Christopher Hirata
AU  - Dana R. Louie
AU  - Gregory Mosby
AU  - Anna Porredon
AU  - Bernard J. Rauscher
AU  - Maxime J. Rizzo
AU  - Rujula Yete
PY  - 2026
DA  - 2026/10/02
PB  - arXiv
DO  - 10.48550/arxiv.2610.03882
UR  - https://arxiv.org/abs/2610.03882
AB  - The Nancy Grace Roman Space Telescope will conduct several community-driven surveys using its Wide Field Instrument (WFI), which contains 18 Teledyne H4RG-10 near-infrared detectors in the focal plane. Roman's wide area survey to measure weak gravitational lensing places particularly stringent requirements on point spread function (PSF) precision for the WFI. The brighter-fatter effect (BFE) is a nonlinear detector effect caused by the deflection of new charge away from pixels with previously accumulated charge during an exposure. As a result, the PSF measured at the detector depends on the charge contrast between pixels, and therefore the effective PSF for astronomical sources is a function of flux contrast and integration time. We present characterization of the BFE observed in a non-flight H4RG by projecting a grid of bright point sources onto the detector using the Talbot Illuminator at the NASA Goddard Space Flight Center Detector Characterization Lab. We find that the effective area of a pixel decreases by (−2.18±0.04) × 10^−6 per electron of charge contrast with its neighbors, corresponding to a measurable increase in the effective PSF size over the course of an exposure. Despite charge migration, the total signal detected in the vicinity of a bright source is roughly conserved. We also analyze flat field statistics for the same detector to measure the total inter-pixel nonlinearity (IPNL), which is dominated by BFE. We present a method to correct BFE in H4RG images using the flat field IPNL results, adapted from an extant optical correction technique. The correction reduces the observed BFE by about a factor of 25 as measured by the effective pixel area change, but there is remaining nonlinearity in the corrected data. We discuss possible sources of residual nonlinearity and suggest avenues to investigate optimal BFE correction in Roman survey images.
ER  -