Skip to content
DraconiticResearch
Search Sources API
194,220 studies31 sourcesUpdated 48 min ago
Peer-reviewedCC BYCureus

Diagnostic Accuracy of Rapid Diagnostic Tests Versus Enzyme-Linked Immunosorbent Assay (ELISA) Across Major Infectious Diseases: A Systematic Review and Meta-Analysis

4 affiliations
  1. 1Microbiology, Gautam Buddha Chikitsa Mahavidyalaya, Dr. K.K.B.M Subharti Hospital, Dehradun, IND
  2. 2Pharmacology, Gautam Buddha Chikitsa Mahavidyalaya, Dr. K.K.B.M Subharti Hospital, Dehradun, IND
  3. 3Microbiology, All India Institute of Medical Sciences, Guwahati, Guwahati, IND
  4. 4Microbiology, Himalayan Institute of Medical Sciences, Swami Rama Himalayan University, Dehradun, IND

Abstract

Rapid diagnostic tests (RDTs) are increasingly used for point-of-care diagnosis of infectious diseases because of their rapid turnaround time and ease of use. However, their diagnostic performance compared with enzyme-linked immunosorbent assay (ELISA) varies across diseases and assay platforms. This systematic review and meta-analysis was conducted according to PRISMA 2020 guidelines. A total of 26 studies were included in the qualitative synthesis, of which 13 datasets from 11 studies with complete 2 × 2 diagnostic data were included in the meta-analysis. Quality assessment was performed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2). Pooled diagnostic performance was summarized separately for each infection using extracted true-positive (TP), false-positive (FP), true-negative (TN), and false-negative (FN) values; forest plots, an HSROC (Hierarchical Summary Receiver Operating Characteristic model)-style summary visualization, and a Deeks-type funnel plot were generated. The aggregate diagnostic counts were TP = 1,304, FP = 68, TN = 24,301, and FN = 303. Overall, the included datasets showed consistently high specificity (≥96.97%), whereas sensitivity varied widely (25%-100%) across conditions. By target condition, the pooled sensitivity and specificity were human immunodeficiency virus (HIV; 78.6%/99.30%), hepatitis B virus (HBV; 88.2%/99.94%), hepatitis C virus (HCV; 75.7%/99.42%), dengue (97.0%/99.97%), and malaria (100.0%/97.18%). RDTs demonstrated high specificity and good sensitivity compared with ELISA, supporting their role as rapid screening tools, particularly in resource-limited settings. However, heterogeneity across diseases and assay platforms limits generalizability, and confirmatory testing remains important in selected clinical and blood-screening settings.

Related

  1. Accuracy of diagnostic codes and algorithms used to identify connective tissue diseases in electronic health records and administrative databases: systematic review and meta-analysis.
    C. Saka-Herran, T. Mani Prabu Kumar, D. Keane +8
    medRxivPreprintCC BYFull textGeneral medicinemedRxiv
  2. Research protocol for the diagnostic accuracy of intelligent portable impulse oscillometry across different respiratory diseases: a multicentre, cross-sectional study
    Bingxia Chen, Shubing Chen, Zhongping Wu +9
    BMJ OpenPeer-reviewedCC BY-NC 4.0Full textGeneral medicineCrossrefEurope PMC
  3. Relic of the Past or Clinical Compass? Re-Evaluating the Diagnostic Utility of Proton Magnetic Resonance Spectroscopy (1H-MRS) in Encephalitis and Infectious CNS Diseases
    Maciej Naumowicz, Radosław Zawadzki, Joanna Zajkowska +1
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  4. Global burden of enteric infectious diseases, diarrhoeal diseases, and corresponding aetiologies, 1990–2023: a systematic analysis for the Global Burden of Disease Study 2023
    Avina Vongpradith, Regina-Mae Villanueva Dominguez, Lorainne Tudor Car +97
    The Lancet Infectious DiseasesPeer-reviewedLicence not statedFull text24 citedInfectious diseaseOpenAlex
  5. Diagnostic accuracy of the appendicitis inflammatory response (AIR) score for acute appendicitis during pregnancy: A systematic review and diagnostic meta-analysis
    Yasaman Tavakoli, Behdad Ghanami, Azad Alimohammadi +1
    Surgery in practice and sciencePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{gupta2026diagnostic,
  title = {{Diagnostic Accuracy of Rapid Diagnostic Tests Versus Enzyme-Linked Immunosorbent Assay (ELISA) Across Major Infectious Diseases: A Systematic Review and Meta-Analysis}},
  author = {Priyanka Gupta and Saurabh Bijalwan and Deepjyoti Kalita and Garima Mittal},
  journal = {Cureus},
  year = {2026},
  month = sep,
  doi = {10.7759/cureus.117107},
  url = {https://europepmc.org/article/PMC/PMC13716983},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Diagnostic Accuracy of Rapid Diagnostic Tests Versus Enzyme-Linked Immunosorbent Assay (ELISA) Across Major Infectious Diseases: A Systematic Review and Meta-Analysis
AU  - Priyanka Gupta
AU  - Saurabh Bijalwan
AU  - Deepjyoti Kalita
AU  - Garima Mittal
PY  - 2026
DA  - 2026/09/28
JO  - Cureus
DO  - 10.7759/cureus.117107
UR  - https://europepmc.org/article/PMC/PMC13716983
AB  - Rapid diagnostic tests (RDTs) are increasingly used for point-of-care diagnosis of infectious diseases because of their rapid turnaround time and ease of use. However, their diagnostic performance compared with enzyme-linked immunosorbent assay (ELISA) varies across diseases and assay platforms. This systematic review and meta-analysis was conducted according to PRISMA 2020 guidelines. A total of 26 studies were included in the qualitative synthesis, of which 13 datasets from 11 studies with complete 2 × 2 diagnostic data were included in the meta-analysis. Quality assessment was performed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2). Pooled diagnostic performance was summarized separately for each infection using extracted true-positive (TP), false-positive (FP), true-negative (TN), and false-negative (FN) values; forest plots, an HSROC (Hierarchical Summary Receiver Operating Characteristic model)-style summary visualization, and a Deeks-type funnel plot were generated. The aggregate diagnostic counts were TP = 1,304, FP = 68, TN = 24,301, and FN = 303. Overall, the included datasets showed consistently high specificity (≥96.97%), whereas sensitivity varied widely (25%-100%) across conditions. By target condition, the pooled sensitivity and specificity were human immunodeficiency virus (HIV; 78.6%/99.30%), hepatitis B virus (HBV; 88.2%/99.94%), hepatitis C virus (HCV; 75.7%/99.42%), dengue (97.0%/99.97%), and malaria (100.0%/97.18%). RDTs demonstrated high specificity and good sensitivity compared with ELISA, supporting their role as rapid screening tools, particularly in resource-limited settings. However, heterogeneity across diseases and assay platforms limits generalizability, and confirmatory testing remains important in selected clinical and blood-screening settings.
SN  - 2168-8184
ER  -