Deep learning-based super-resolution ultrashort echo time MRI combined with free-breathing Star-VIBE dynamic contrast-enhanced MRI for characterization of Lung-RADS 4 pulmonary nodules
- 1Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
Abstract
Background: Lung Imaging Reporting and Data System (Lung-RADS) 4 pulmonary nodules require further evaluation because of indeterminate malignancy risk. However, repeated computed tomography (CT) examinations raise concerns about cumulative radiation exposure, and ultrashort echo time magnetic resonance imaging (UTE-MRI) remains limited by spatial resolution and motion sensitivity. This study aimed to assess the diagnostic performance of generative adversarial network (GAN)-based super-resolution UTE MRI (SR-UTE-MRI) in combination with star-volumetric interpolated breath hold examination (Star-VIBE) dynamic contrast-enhanced MRI (DCE-MRI) for such nodules, using CT and histopathological findings as reference standards.
Methods: In this prospective study, patients with Lung-RADS 4 pulmonary nodules underwent CT, free-breathing UTE-MRI with subsequent SR reconstruction, and Star-VIBE DCE-MRI. Nodule size, morphological features, and perfusion parameters were assessed. Diagnostic performance of individual imaging metrics and a combined model was evaluated using receiver operating characteristic (ROC) curve analysis. A total of 91 patients (43 men and 48 women; mean age, 56.2±13.9 years) with 91 nodules (27 part-solid and 64 solid; mean diameter, 24.1±8.9 mm) were finally included.
Results: Measurements derived from UTE-MRI underestimated mean nodule diameter relative to CT, resulting in misclassification in a subset of nodules. SR-UTE-MRI images reduced measurement bias and improved Lung-RADS classification accuracy and visualization of morphological features. Malignant pulmonary nodules demonstrated significantly higher volume transfer constant (Ktrans) and rate constant (Kep) values compared with benign nodules (Ktrans: 0.28 ± 0.19 min−1 vs. 0.16±0.11 min−1, P<0.001; Kep: 0.79±0.38 min−1 vs. 0.53±0.23 min−1,P<0.001). Among individual parameters, Ktrans exhibited the highest diagnostic performance [area under the curve (AUC) =0.799; cut-off, 0.14 min−1]. A multiparametric model incorporating perfusion parameters, nodule size, and spiculation yielded superior discriminatory performance (AUC =0.946; sensitivity =91%; specificity =88%; accuracy =90%).
Conclusions: GAN-based SR-UTE reduced the underestimation of lesion size associated with UTE-MRI and improved the accuracy of Lung-RADS classification. Star-VIBE DCE-MRI provided quantitative functional biomarkers for the assessment of malignancy. The integration of structural and functional imaging parameters yielded superior diagnostic performance compared with single-modality or single-parameter approaches, highlighting its potential as a comprehensive, non-ionizing imaging strategy for evaluation of indeterminate pulmonary nodules.
Related
- Comparison of Pulmonary Nodule Morphology on Pre-Contrast and Delayed Post-Contrast Stack-of-Spirals Ultrashort Echo Time MRI.
- Machine learning-based electrofacies characterization of the Asmari reservoir in the Ahvaz oil field (SW Iran) using multi-resolution graph-based clustering (MRGC) and hydraulic flow unit (HFU) analysis
- Deep Learning Reconstruction for Ultra-High-Resolution Photon-Counting CT of the Lung: Image Quality and Texture Characterization
- A retrospective analysis of tidal breathing pulmonary function characteristics in infants and young children with recurrent wheezing
- Obstructive Sleep Apnea and Pulmonary Embolism: Prevalence, Severity and the Association of Sleep-Disordered Breathing with Thromboembolic Disease
BibTeX
@article{liu2026deep,
title = {{Deep learning-based super-resolution ultrashort echo time MRI combined with free-breathing Star-VIBE dynamic contrast-enhanced MRI for characterization of Lung-RADS 4 pulmonary nodules}},
author = {Hui Liu and Meng-Ting Duan and Ning Zhang and Li-Jia Wang and Xiao-Jia Cai and Si-Xue Xie and Gao-Feng Shi and Hui Feng},
journal = {Quantitative Imaging in Medicine and Surgery},
year = {2026},
month = oct,
doi = {10.21037/qims-2026-1365},
url = {https://doi.org/10.21037/qims-2026-1365},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Deep learning-based super-resolution ultrashort echo time MRI combined with free-breathing Star-VIBE dynamic contrast-enhanced MRI for characterization of Lung-RADS 4 pulmonary nodules
AU - Hui Liu
AU - Meng-Ting Duan
AU - Ning Zhang
AU - Li-Jia Wang
AU - Xiao-Jia Cai
AU - Si-Xue Xie
AU - Gao-Feng Shi
AU - Hui Feng
PY - 2026
DA - 2026/10/20
JO - Quantitative Imaging in Medicine and Surgery
DO - 10.21037/qims-2026-1365
UR - https://doi.org/10.21037/qims-2026-1365
AB - Background: Lung Imaging Reporting and Data System (Lung-RADS) 4 pulmonary nodules require further evaluation because of indeterminate malignancy risk. However, repeated computed tomography (CT) examinations raise concerns about cumulative radiation exposure, and ultrashort echo time magnetic resonance imaging (UTE-MRI) remains limited by spatial resolution and motion sensitivity. This study aimed to assess the diagnostic performance of generative adversarial network (GAN)-based super-resolution UTE MRI (SR-UTE-MRI) in combination with star-volumetric interpolated breath hold examination (Star-VIBE) dynamic contrast-enhanced MRI (DCE-MRI) for such nodules, using CT and histopathological findings as reference standards. Methods: In this prospective study, patients with Lung-RADS 4 pulmonary nodules underwent CT, free-breathing UTE-MRI with subsequent SR reconstruction, and Star-VIBE DCE-MRI. Nodule size, morphological features, and perfusion parameters were assessed. Diagnostic performance of individual imaging metrics and a combined model was evaluated using receiver operating characteristic (ROC) curve analysis. A total of 91 patients (43 men and 48 women; mean age, 56.2±13.9 years) with 91 nodules (27 part-solid and 64 solid; mean diameter, 24.1±8.9 mm) were finally included. Results: Measurements derived from UTE-MRI underestimated mean nodule diameter relative to CT, resulting in misclassification in a subset of nodules. SR-UTE-MRI images reduced measurement bias and improved Lung-RADS classification accuracy and visualization of morphological features. Malignant pulmonary nodules demonstrated significantly higher volume transfer constant (Ktrans) and rate constant (Kep) values compared with benign nodules (Ktrans: 0.28 ± 0.19 min−1 vs. 0.16±0.11 min−1, P<0.001; Kep: 0.79±0.38 min−1 vs. 0.53±0.23 min−1,P<0.001). Among individual parameters, Ktrans exhibited the highest diagnostic performance [area under the curve (AUC) =0.799; cut-off, 0.14 min−1]. A multiparametric model incorporating perfusion parameters, nodule size, and spiculation yielded superior discriminatory performance (AUC =0.946; sensitivity =91%; specificity =88%; accuracy =90%). Conclusions: GAN-based SR-UTE reduced the underestimation of lesion size associated with UTE-MRI and improved the accuracy of Lung-RADS classification. Star-VIBE DCE-MRI provided quantitative functional biomarkers for the assessment of malignancy. The integration of structural and functional imaging parameters yielded superior diagnostic performance compared with single-modality or single-parameter approaches, highlighting its potential as a comprehensive, non-ionizing imaging strategy for evaluation of indeterminate pulmonary nodules.
SN - 2223-4292
SN - 2223-4306
ER -