Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 12 min ago
Peer-reviewedCC BY 4.0European Radiology Experimental

Combining shear wave elastography and ultrasound localization microscopy for liver fibrosis staging in a rat model

  1. 1National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, China

Abstract

Objective: Accurate staging of liver fibrosis (LF) remains a clinical challenge. This study aimed to quantitatively evaluate the diagnostic value of combining shear wave elastography (SWE) and ultrasound localization microscopy (ULM) for LF staging across the full disease spectrum. We sought to integrate liver mechanical properties and microvascular structural parameters to build a multiparametric model for fibrosis staging.

Materials and methods: LF was induced in Sprague–Dawley rats and histologically staged according to the METAVIR system. A total of 62 rats were included in the final analysis. Both SWE and ULM were performed in each animal. Liver viscoelastic moduli were estimated from SWE data using SW-VEI-Net, a physics-informed neural network-based approach. ULM data were post-processed to reconstruct super-resolution images of the hepatic microvasculature, followed by quantitative analysis to extract microvascular structural parameters.

Results: Histology revealed fibrosis stages F0 (n = 10), F1 (n = 12), F2 (n = 19), F3 (n = 11), and F4 (n = 10). Compared with the single-modality SWE and ULM models, the multiparametric combined model achieved the highest numerical areas under the receiver operating characteristic curve across the four classification tasks: 0.93 for F0 versus F1–F4, 0.92 for F0–F1 versus F2–F4, 0.90 for F0–F2 versus F3–F4, and 0.89 for F0–F3 versus F4.

Conclusion: Combining SWE-derived viscoelastic parameters with ULM-derived microvascular features enabled multiparametric characterization of LF in this preclinical rat model. Independent validation in larger animal cohorts and, ultimately, human studies is essential before robust clinical conclusions can be drawn.

Key Points: Question Can combining shear-wave elastography (SWE) and ULM improve the accuracy of LF staging?

Findings By integrating viscoelastic and microvascular features, the SWE-ULM combined model achieved the highest numerical AUCs across all four fibrosis classifications in a rat model.

Relevance statement The SWE and ULM combined model suggests potential value for LF staging by integrating viscoelastic and microvascular biomarkers, providing a basis for further investigation toward future clinical translation.

Graphical Abstract:

Related

  1. Ultrasound findings across liver fibrosis stages defined by transient elastography in patients with chronic hepatitis B in Georgia
    Lela Inaishvili, Elene Gotsiridze, Lasha Gulbiani +2
    Journal of UltrasoundPeer-reviewedLicence not statedFull textGeneral medicinePMC
  2. Optimizing the contrast agent dose and image acquisition time for renal ultrasound localization microscopy
    Jing Zhang, Jiahao Han, Pingping Wang +3
    European Radiology ExperimentalPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMC
  3. Assessment of biopsy‐proven liver fibrosis by two‐dimensional shear wave elastography: An individual patient data‐based meta‐analysis
    Eva Herrmann, Victor de Lédinghen, Christophe Cassinotto +28
    HepatologyPeer-reviewedHAL deposit licenceFull text466 citedSystems & synthetic biologyMedical imaging & radiologyHAL
  4. Thoracic ultrasound elastography in pleural and subpleural diseases: a narrative review
    Guido Marchi, Carmine Salerni, Jacopo Cefalo +5
    Journal of UltrasoundPeer-reviewedLicence not statedFull textMedical imaging & radiologyPMC
  5. Diagnostic performance of ultrasound elastography for assessing liver stiffness in children with non-alcoholic fatty liver disease and biliary atresia
    Peijiao Jiang, Yinlian Bai, Yi He +2
    American Journal of Translational ResearchPeer-reviewedLicence not statedFull textMedical imaging & radiologyPMC
BibTeX
@article{zhang2026combining,
  title = {{Combining shear wave elastography and ultrasound localization microscopy for liver fibrosis staging in a rat model}},
  author = {Yue Zhang and Haoming Lin and Xinli Kong and Huiying Wen and Zhongjun Ma and Mian Chen and Siping Chen and Xin Chen and Zhong Liu},
  journal = {European Radiology Experimental},
  year = {2026},
  month = nov,
  doi = {10.1186/s41747-026-00841-9},
  url = {https://doi.org/10.1186/s41747-026-00841-9},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Combining shear wave elastography and ultrasound localization microscopy for liver fibrosis staging in a rat model
AU  - Yue Zhang
AU  - Haoming Lin
AU  - Xinli Kong
AU  - Huiying Wen
AU  - Zhongjun Ma
AU  - Mian Chen
AU  - Siping Chen
AU  - Xin Chen
AU  - Zhong Liu
PY  - 2026
DA  - 2026/11/06
JO  - European Radiology Experimental
DO  - 10.1186/s41747-026-00841-9
UR  - https://doi.org/10.1186/s41747-026-00841-9
AB  - Objective: Accurate staging of liver fibrosis (LF) remains a clinical challenge. This study aimed to quantitatively evaluate the diagnostic value of combining shear wave elastography (SWE) and ultrasound localization microscopy (ULM) for LF staging across the full disease spectrum. We sought to integrate liver mechanical properties and microvascular structural parameters to build a multiparametric model for fibrosis staging.  Materials and methods: LF was induced in Sprague–Dawley rats and histologically staged according to the METAVIR system. A total of 62 rats were included in the final analysis. Both SWE and ULM were performed in each animal. Liver viscoelastic moduli were estimated from SWE data using SW-VEI-Net, a physics-informed neural network-based approach. ULM data were post-processed to reconstruct super-resolution images of the hepatic microvasculature, followed by quantitative analysis to extract microvascular structural parameters.  Results: Histology revealed fibrosis stages F0 (n = 10), F1 (n = 12), F2 (n = 19), F3 (n = 11), and F4 (n = 10). Compared with the single-modality SWE and ULM models, the multiparametric combined model achieved the highest numerical areas under the receiver operating characteristic curve across the four classification tasks: 0.93 for F0 versus F1–F4, 0.92 for F0–F1 versus F2–F4, 0.90 for F0–F2 versus F3–F4, and 0.89 for F0–F3 versus F4.  Conclusion: Combining SWE-derived viscoelastic parameters with ULM-derived microvascular features enabled multiparametric characterization of LF in this preclinical rat model. Independent validation in larger animal cohorts and, ultimately, human studies is essential before robust clinical conclusions can be drawn.  Key Points: Question Can combining shear-wave elastography (SWE) and ULM improve the accuracy of LF staging?  Findings By integrating viscoelastic and microvascular features, the SWE-ULM combined model achieved the highest numerical AUCs across all four fibrosis classifications in a rat model.  Relevance statement The SWE and ULM combined model suggests potential value for LF staging by integrating viscoelastic and microvascular biomarkers, providing a basis for further investigation toward future clinical translation.  Graphical Abstract:
SN  - 2509-9280
ER  -