Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 37 min ago
Peer-reviewedCC BY 4.0Current Medical Imaging

Assessment of a Transverse-Sigmoid Sinus Dural Arteriovenous Fistula using Transcranial Doppler Ultrasonography: A Case Report

  1. 1Department of Neurology, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, Anhui Province, China
  2. 2Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
  3. 3Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, Anhui Province, China

Abstract

Background: The most common symptoms of transverse-sigmoid sinus dural arteriovenous fistula (TS-S DAVF) are pulsatile tinnitus and headache. The clinical characteristics lack specificity and may lead to misdiagnosis or delayed diagnosis. The noninvasive and convenient nature of neurovascular ultrasound has made it an important screening tool for lesions. This paper reports the use of transcranial Doppler (TCD) ultrasonography for the preoperative screening and postoperative follow-up of a patient diagnosed with a transverse-sigmoid sinus dural arteriovenous fistula (TS-S DAVF).

Case Presentation: A 62-year-old female was admitted with a six-month history of headache and tinnitus on the left side. A structured TCD-based approach was used to evaluate intracranial and extracranial hemodynamics. The protocol included targeted probe positioning based on anatomical landmarks, spectral waveform analysis, and the superficial temporal artery tap maneuver. The preoperative TCD results indicated hemodynamic alterations with increased flow and decreased resistance in the left common carotid artery, external carotid artery, and occipital artery. The presence of a Cognard Type III DAVF in the left transverse sinus-sigmoid sinus was confirmed through DSA. The occipital artery and the posterior branch of the middle meningeal artery were the key feeding arteries with cortical vein drainage to the sigmoid sinus. After endovascular embolization via the venous approach, follow-up TCD showed normal hemodynamics in the previously affected arteries, consistent with complete resolution of the patient’s clinical symptoms.

Conclusion: A structured TCD-based approach may help identify shunt-related hemodynamic abnormalities in suspected TS-S DAVF and support post-embolization follow-up. Cerebral DSA remains necessary for definitive diagnosis and treatment planning.

Related

  1. Intraoperative specimen ultrasonography for margin assessment in breast conserving surgery in comparison with specimen mammography
    Alexia Mensah, Sendhil Rajan, Lukschana Senathirajah +4
    Surgery in practice and sciencePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  2. Morphological and vascular assessment of mandibular nutrient foramina using cone beam computed tomography and Color Doppler ultrasonography
    Menduh Sercan Kaya, Mehmet Emin Doğan, Sedef Kotanlı
    Scientific ReportsPeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefDOAJ
  3. Dynamic assessment of renal resistive index using point-of-care ultrasonography for early detection of sepsis-induced acute kidney injury: A multicenter clinical trial protocol
    Zongfang Ren, Lingling Wang, Jinxi Yue +3
    PLOS OnePeer-reviewedCC BYFull textGeneral biochemistryGeneral biologyPLOSEurope PMCPMC
  4. Assessment of Sling Characteristics After Transobturator Tape Placement Using Transperineal Ultrasonography: Relationship with Continence and Dyspareunia—A Cross-Sectional Study
    Mehmet Koçoğlu, Oya Soylu Karapınar, Muhammed Tosun +1
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCCrossref
  5. Personalized assessment of high-definition slow-oscillatory transcranial direct current stimulation (so-tDCS) in older adults with sleep and subjective cognitive complaints: A study protocol for a randomized clinical trial
    Hanna Lu, Xi Ni, Natalie Shu Yang +3
    PLOS OnePeer-reviewedCC BY 4.0Full textNeuroscienceClinical trials & evidence synthesisPLOS
BibTeX
@article{peng2026assessment,
  title = {{Assessment of a Transverse-Sigmoid Sinus Dural Arteriovenous Fistula using Transcranial Doppler Ultrasonography: A Case Report}},
  author = {Xiangxiang Peng and Shan Geng and Zhang Xiong and Zhiming Zhou},
  journal = {Current Medical Imaging},
  year = {2026},
  month = aug,
  doi = {10.2174/0115734056473694260723114721},
  url = {https://doi.org/10.2174/0115734056473694260723114721},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Assessment of a Transverse-Sigmoid Sinus Dural Arteriovenous Fistula using Transcranial Doppler Ultrasonography: A Case Report
AU  - Xiangxiang Peng
AU  - Shan Geng
AU  - Zhang Xiong
AU  - Zhiming Zhou
PY  - 2026
DA  - 2026/08/05
JO  - Current Medical Imaging
DO  - 10.2174/0115734056473694260723114721
UR  - https://doi.org/10.2174/0115734056473694260723114721
AB  - Background: The most common symptoms of transverse-sigmoid sinus dural arteriovenous fistula (TS-S DAVF) are pulsatile tinnitus and headache. The clinical characteristics lack specificity and may lead to misdiagnosis or delayed diagnosis. The noninvasive and convenient nature of neurovascular ultrasound has made it an important screening tool for lesions. This paper reports the use of transcranial Doppler (TCD) ultrasonography for the preoperative screening and postoperative follow-up of a patient diagnosed with a transverse-sigmoid sinus dural arteriovenous fistula (TS-S DAVF).  Case Presentation: A 62-year-old female was admitted with a six-month history of headache and tinnitus on the left side. A structured TCD-based approach was used to evaluate intracranial and extracranial hemodynamics. The protocol included targeted probe positioning based on anatomical landmarks, spectral waveform analysis, and the superficial temporal artery tap maneuver. The preoperative TCD results indicated hemodynamic alterations with increased flow and decreased resistance in the left common carotid artery, external carotid artery, and occipital artery. The presence of a Cognard Type III DAVF in the left transverse sinus-sigmoid sinus was confirmed through DSA. The occipital artery and the posterior branch of the middle meningeal artery were the key feeding arteries with cortical vein drainage to the sigmoid sinus. After endovascular embolization via the venous approach, follow-up TCD showed normal hemodynamics in the previously affected arteries, consistent with complete resolution of the patient’s clinical symptoms.  Conclusion: A structured TCD-based approach may help identify shunt-related hemodynamic abnormalities in suspected TS-S DAVF and support post-embolization follow-up. Cerebral DSA remains necessary for definitive diagnosis and treatment planning.
SN  - 1573-4056
ER  -