Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 59 min ago
Peer-reviewedCC BY-NC-NDJournal of medical case reports

Iatrogenic axillary arteriovenous fistula complicating permanent pacemaker implantation: successful management with a balloon-expandable covered stent-a case report.

  1. 1Gansu University of Chinese Medicine, Lanzhou, 730000, Gansu Province, China.
  2. 2The First People's Hospital of Tianshui, Tianshui, 741000, Gansu Province, China.
  3. 3The First People's Hospital of Tianshui, Tianshui, 741000, Gansu Province, China. [email protected].

Abstract

Background

Third-degree atrioventricular block is a class I indication for permanent pacemaker implantation. Iatrogenic axillary arteriovenous fistula is an extremely rare vascular complication of this procedure with limited clinical reports to date.Case presentation

We present the case of a 57-year-old male with third-degree atrioventricular block who developed an axillary arteriovenous fistula during permanent pacemaker implantation via the left axillary vein approach. The complication was promptly diagnosed by emergency axillary arteriography and was successfully occluded with an 8 mm × 37 mm balloon-expandable covered stent. Owing to the ipsilateral vascular injury, the pre‑created left pacemaker pocket was then closed in layers. Permanent pacemaker implantation was subsequently completed uneventfully via the contralateral right axillary vein approach, with a new pacemaker pocket created on the right side. The patient had an uncomplicated postoperative course and normal pacemaker function at the 1-month follow-up, with no recurrence of symptoms or vascular abnormalities.Conclusions

We review the relevant literature, analyze the pathophysiology, diagnosis and interventional management of this rare complication, and propose clinical recommendations for its prevention and acute management, including rational pacemaker pocket management after successful vascular fistula occlusion. This case reinforces the efficacy and safety of balloon-expandable covered stents for iatrogenic axillary arteriovenous fistula and highlights the importance of multidisciplinary collaboration, prompt angiographic diagnosis, and deliberate pocket selection in the management of such acute procedural complications.

Related

  1. Successful conservative management of hepatic portal venous gas complicating severe immune-related gastrointestinal injury during pembrolizumab-based concurrent chemoradiotherapy for cervical cancer: a mechanistic case report
    Miwa Minamitani, Hideaki Tsuyoshi, Tatsushi Naito +2
    Frontiers in oncologyPeer-reviewedCC BYFull textOncologyEurope PMCCrossref
  2. Delayed Renal Artery Stump Pseudoaneurysm and Arteriovenous Fistula Following Nephrectomy Complicated by Pulmonary Coil Migration: Successful Laparoscopic Management
    Paulina Mizera, Karol Kamil Kłosiński, Joanna Maria Czyżewska +3
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  3. Successful treatment of refractory hemophagocytic lymphohistiocytosis complicating Epstein–Barr virus-positive classic Hodgkin lymphoma with rituximab
    Satoshi Ichikawa, Yutaka Suzuki, Yuya Tanaka +7
    Journal of Clinical and Experimental Hematopathology : JCEHPeer-reviewedCC BY-NC-SA 4.0Full textGeneral medicinePMC
  4. Catheter-related deep vein thrombosis complicated by iatrogenic pulmonary embolism after thrombectomy leading to hemodialysis failure and successful rescue by automated peritoneal dialysis : A case report
    Wenhui Lu, Rui Gong, Xi Liu +3
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMCEurope PMC
  5. Endovascular ultrasound-guided endoprosthesis implantation for post-traumatic arteriovenous fistulas: overcoming the limitations of angiographic imaging
    Y. H. Vahis, S. M. Furkalo
    Український журнал клінічної хірургіїPeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJ
BibTeX
@article{peipei2026iatrogenic,
  title = {{Iatrogenic axillary arteriovenous fistula complicating permanent pacemaker implantation: successful management with a balloon-expandable covered stent-a case report.}},
  author = {Jia Peipei and Zhou Shiqiang and Du Nana and Dong Wenjie and Lei Xiaoting and Hong Zhibin},
  journal = {Journal of medical case reports},
  year = {2026},
  month = aug,
  doi = {10.1186/s13256-026-06322-2},
  url = {https://europepmc.org/article/MED/43058875},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Iatrogenic axillary arteriovenous fistula complicating permanent pacemaker implantation: successful management with a balloon-expandable covered stent-a case report.
AU  - Jia Peipei
AU  - Zhou Shiqiang
AU  - Du Nana
AU  - Dong Wenjie
AU  - Lei Xiaoting
AU  - Hong Zhibin
PY  - 2026
DA  - 2026/08/25
JO  - Journal of medical case reports
DO  - 10.1186/s13256-026-06322-2
UR  - https://europepmc.org/article/MED/43058875
AB  - Background  Third-degree atrioventricular block is a class I indication for permanent pacemaker implantation. Iatrogenic axillary arteriovenous fistula is an extremely rare vascular complication of this procedure with limited clinical reports to date.Case presentation  We present the case of a 57-year-old male with third-degree atrioventricular block who developed an axillary arteriovenous fistula during permanent pacemaker implantation via the left axillary vein approach. The complication was promptly diagnosed by emergency axillary arteriography and was successfully occluded with an 8 mm × 37 mm balloon-expandable covered stent. Owing to the ipsilateral vascular injury, the pre‑created left pacemaker pocket was then closed in layers. Permanent pacemaker implantation was subsequently completed uneventfully via the contralateral right axillary vein approach, with a new pacemaker pocket created on the right side. The patient had an uncomplicated postoperative course and normal pacemaker function at the 1-month follow-up, with no recurrence of symptoms or vascular abnormalities.Conclusions  We review the relevant literature, analyze the pathophysiology, diagnosis and interventional management of this rare complication, and propose clinical recommendations for its prevention and acute management, including rational pacemaker pocket management after successful vascular fistula occlusion. This case reinforces the efficacy and safety of balloon-expandable covered stents for iatrogenic axillary arteriovenous fistula and highlights the importance of multidisciplinary collaboration, prompt angiographic diagnosis, and deliberate pocket selection in the management of such acute procedural complications.
SN  - 1752-1947
ER  -