Left ventricular assist device implantation in a 'turtle-shell' sclerotic left ventricular apex: a case report of landing-zone selection and tailored fixation strategy.
- 1Department of Cardiovascular Surgery, The First Affiliated Hospital of Wannan Medical University (Yijishan Hospital of Wannan Medical University), No. 2 Zheshan West Road, Wuhu, Anhui 241000, China.
Abstract
Background
Left ventricular assist device (LVAD) implantation usually requires a compliant and structurally suitable left ventricular apex for coring, sewing-ring fixation, and inflow cannula alignment. Severe apical sclerosis may eliminate the conventional implantable apex.Case summary
A 73-year-old man with ischaemic cardiomyopathy and refractory advanced heart failure underwent Corheart-6 LVAD implantation. Preoperative imaging showed severe ventricular dilatation, biventricular dysfunction, functional mitral and tricuspid regurgitation, and a markedly abnormal apical segment with thinning, akinesia, outward bulging, and mural mass formation. Intraoperatively, dense apical adhesions and a rigid 3- to 4-cm 'turtle-shell-like' sclerotic region were encountered. After limited dissection and repair of a localized rupture, the conventional apical target was considered unsuitable for safe coring and sewing-ring fixation. To preserve an acceptable inflow axis while avoiding major coronary structures, an adjacent viable myocardial landing zone at approximately the 5-o'clock position was selected. Circumferential pledgeted 3-0 Prolene sutures were used for reinforced sewing-ring fixation. Because the intracavitary pathway remained restrictive, limited assessment and targeted trimming of interfering secondary chordal tissue were performed only as needed to accommodate the inflow cannula. No obvious papillary muscle or major trabecular structure was resected. Implantation was completed with satisfactory haemostasis. The patient was discharged on postoperative Day 17 and remained clinically stable with normal daily activities at the 24-month follow-up.Conclusion
In severe apical sclerosis, LVAD implantation should prioritize optimal inflow cannula position and feasible inflow-axis alignment. Landing-zone selection, reinforced fixation, and limited intracavitary modification are enabling manoeuvres to achieve an unobstructed inflow pathway.
Related
- Multiple right ventricular pseudoaneurysms after helix-fixation leadless pacemaker implantation.
- Feasibility and procedural considerations of a helix-fixation leadless pacemaker implantation in patients with left ventricular assist devices.
- Coronary stent fixation of left ventricular lead during CRT-D implantation: a case series of three patients
- Right ventricular assist device support during left ventricular assist device implantation: indications, timing, device selection, and perioperative management
- Delayed Implantation of a Maxillary Central Incisor Using a Modified Anatomic Healing Abutment and Transmembrane‐Fixation Guided Bone Regeneration: A Case Report
BibTeX
@article{sheng2026left,
title = {{Left ventricular assist device implantation in a 'turtle-shell' sclerotic left ventricular apex: a case report of landing-zone selection and tailored fixation strategy.}},
author = {Weiyong Sheng and Tiansheng Tang and Youshi Wu and Saifane Zakaria and Dafa Zhang},
journal = {European heart journal. Case reports},
year = {2026},
month = oct,
doi = {10.1093/ehjcr/ytag779},
url = {https://europepmc.org/article/MED/43047749},
note = {CC BY},
}
RIS
TY - JOUR
TI - Left ventricular assist device implantation in a 'turtle-shell' sclerotic left ventricular apex: a case report of landing-zone selection and tailored fixation strategy.
AU - Weiyong Sheng
AU - Tiansheng Tang
AU - Youshi Wu
AU - Saifane Zakaria
AU - Dafa Zhang
PY - 2026
DA - 2026/10/24
JO - European heart journal. Case reports
DO - 10.1093/ehjcr/ytag779
UR - https://europepmc.org/article/MED/43047749
AB - Background Left ventricular assist device (LVAD) implantation usually requires a compliant and structurally suitable left ventricular apex for coring, sewing-ring fixation, and inflow cannula alignment. Severe apical sclerosis may eliminate the conventional implantable apex.Case summary A 73-year-old man with ischaemic cardiomyopathy and refractory advanced heart failure underwent Corheart-6 LVAD implantation. Preoperative imaging showed severe ventricular dilatation, biventricular dysfunction, functional mitral and tricuspid regurgitation, and a markedly abnormal apical segment with thinning, akinesia, outward bulging, and mural mass formation. Intraoperatively, dense apical adhesions and a rigid 3- to 4-cm 'turtle-shell-like' sclerotic region were encountered. After limited dissection and repair of a localized rupture, the conventional apical target was considered unsuitable for safe coring and sewing-ring fixation. To preserve an acceptable inflow axis while avoiding major coronary structures, an adjacent viable myocardial landing zone at approximately the 5-o'clock position was selected. Circumferential pledgeted 3-0 Prolene sutures were used for reinforced sewing-ring fixation. Because the intracavitary pathway remained restrictive, limited assessment and targeted trimming of interfering secondary chordal tissue were performed only as needed to accommodate the inflow cannula. No obvious papillary muscle or major trabecular structure was resected. Implantation was completed with satisfactory haemostasis. The patient was discharged on postoperative Day 17 and remained clinically stable with normal daily activities at the 24-month follow-up.Conclusion In severe apical sclerosis, LVAD implantation should prioritize optimal inflow cannula position and feasible inflow-axis alignment. Landing-zone selection, reinforced fixation, and limited intracavitary modification are enabling manoeuvres to achieve an unobstructed inflow pathway.
SN - 2514-2119
ER -