When Raman Spectral Fidelity and Bacterial Classification Accuracy Diverge
Abstract
Spectral error and classification error can respond differently to the same change in a Raman spectrum. We compared three derivative errors and three versions of spectral information divergence (SID) against mean squared error (MSE) using a fixed bacterial classification task. All derivative errors were less closely aligned with classification harm than MSE. SID improved alignment gap and ordering concordance only after Gaussian smoothing at 10 cm−1. In a separate test, Gaussian broadening increased MSE throughout the tested range, while mean accuracy first rose and then fell. Including broadening among the perturbations retained Wasserstein distance’s advantage over MSE and increased peak F1’s relative disadvantage. For this classifier, closer agreement with the original spectrum did not consistently imply higher accuracy.
Related
- SERS-CBP: A Comprehensive SERS Spectral Database of Clinically Important Bacterial Pathogens.
- FRACTAL: A Ratiometric-based Fingerprinting Framework for Robust Spectral Classification and Ratio-based Spectroscopic Marker Discovery
- Fast structural search for classification of gut bacterial mucin O-glycan degrading enzymes
- Rod photoreceptors have a dual dependency on both aerobic glycolysis and OXPHOS and diverge metabolically from other retinal neurons
- Benchmarking long-read aligner-caller pipelines for structural variant detection across ten angiosperm species with PacBio high-fidelity sequencing
BibTeX
@misc{l2026when,
title = {{When Raman Spectral Fidelity and Bacterial Classification Accuracy Diverge}},
author = {yonghe l},
howpublished = {ECSarXiv},
year = {2026},
month = oct,
doi = {10.1149/osf.io/97am3_v1},
url = {https://osf.io/preprints/ecsarxiv/97am3_v1/},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - When Raman Spectral Fidelity and Bacterial Classification Accuracy Diverge
AU - yonghe l
PY - 2026
DA - 2026/10/13
PB - ECSarXiv
DO - 10.1149/osf.io/97am3_v1
UR - https://osf.io/preprints/ecsarxiv/97am3_v1/
AB - Spectral error and classification error can respond differently to the same change in a Raman spectrum. We compared three derivative errors and three versions of spectral information divergence (SID) against mean squared error (MSE) using a fixed bacterial classification task. All derivative errors were less closely aligned with classification harm than MSE. SID improved alignment gap and ordering concordance only after Gaussian smoothing at 10 cm−1. In a separate test, Gaussian broadening increased MSE throughout the tested range, while mean accuracy first rose and then fell. Including broadening among the perturbations retained Wasserstein distance’s advantage over MSE and increased peak F1’s relative disadvantage. For this classifier, closer agreement with the original spectrum did not consistently imply higher accuracy.
ER -