An advanced LAMP assay targeting the mecA gene in methicillin-resistant Staphylococcus aureus (MRSA) was developed and validated using clinical and foodborne S. aureus isolates. Reference strains, including both methicillin-sensitive and methicillin-resistant S. aureus, were used to evaluate and optimize assay performance. With the newly designed ID16 LAMP primer set, the detection limit for mecA was 15 fg/L of total genomic DNA, equivalent to 5 copies/L, and the assay turnaround time was only 25 min. All mecA-positive isolates identified by conventional qPCR were successfully detected by the LAMP assay. Overall, the developed LAMP method provides a rapid, highly specific, and sensitive alternative for mecA detection.

Related

  1. Highly sensitive and specific detection of aminoglycoside resistance methylase gene armA by multiple cross displacement amplification-CRISPR/Cas12a technique
    Lin Gong, Juan Wang, Yuandong Zhang +8
    Frontiers in cellular and infection microbiologyPeer-reviewedCC BYFull textInfectious diseaseEurope PMCPMCEurope PMC
  2. Detection of Plasmodium vivax and Plasmodium falciparum using colorimetric loop-mediated isothermal amplification from dried blood spots collected in active and passive malaria surveillance in the Peruvian Amazon
    Oscar Nolasco, Joaquín Gómez, Hugo Rodríguez-Ferrucci +2
    PLOS Neglected Tropical DiseasesPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationGenetics & genomicsPLOSPMC
  3. A Duplex Isothermal RPA–Lateral Flow Platform for Concurrent Detection of Staphylococcus Aureus and mecA-Mediated Methicillin Resistance
    Jutturong Ckumdee, Somchai Santiwatanakul, Kwanchai Onruang +1
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMCDOAJ
  4. Electricity Free LAMP: A Protocol for Loop-Mediated Isothermal Amplification Using an Exothermic Chemical Reaction and Lyophilized Reagents
    K. K. Grandhe, T. E. Riedel
    medRxivPreprintCC BY-NCFull textInfectious diseasemedRxiv
  5. Molecular Detection Technologies for Helicobacter pylori Antibiotic Resistance: Current Status and Clinical Implications.
    Zhenyu Wang, Jun Lin, Xuanni Zhang +3
    Current microbiologyPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
BibTeX
@misc{baldenweck2026rapid,
  title = {{A rapid and sensitive Loop-Mediated Isothermal Amplification (LAMP) assay for detection of mecA antibiotic resistance gene in clinical and food bacterial isolates}},
  author = {L. Baldenweck and M. Djisalov and D. Pinamonti and M. manzano and I. Gadjanski and J. Vidic},
  howpublished = {medRxiv},
  year = {2026},
  month = nov,
  doi = {10.64898/2026.11.13.26367169},
  url = {https://www.medrxiv.org/content/10.64898/2026.11.13.26367169v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - A rapid and sensitive Loop-Mediated Isothermal Amplification (LAMP) assay for detection of mecA antibiotic resistance gene in clinical and food bacterial isolates
AU  - L. Baldenweck
AU  - M. Djisalov
AU  - D. Pinamonti
AU  - M. manzano
AU  - I. Gadjanski
AU  - J. Vidic
PY  - 2026
DA  - 2026/11/13
PB  - medRxiv
DO  - 10.64898/2026.11.13.26367169
UR  - https://www.medrxiv.org/content/10.64898/2026.11.13.26367169v1
AB  - An advanced LAMP assay targeting the mecA gene in methicillin-resistant Staphylococcus aureus (MRSA) was developed and validated using clinical and foodborne S. aureus isolates. Reference strains, including both methicillin-sensitive and methicillin-resistant S. aureus, were used to evaluate and optimize assay performance. With the newly designed ID16 LAMP primer set, the detection limit for mecA was 15 fg/L of total genomic DNA, equivalent to 5 copies/L, and the assay turnaround time was only 25 min. All mecA-positive isolates identified by conventional qPCR were successfully detected by the LAMP assay. Overall, the developed LAMP method provides a rapid, highly specific, and sensitive alternative for mecA detection.
ER  -