PreprintCC BYmedRxiv
A rapid and sensitive Loop-Mediated Isothermal Amplification (LAMP) assay for detection of mecA antibiotic resistance gene in clinical and food bacterial isolates
- 1INRAE
Abstract
An advanced LAMP assay targeting the mecA gene in methicillin-resistant Staphylococcus aureus (MRSA) was developed and validated using clinical and foodborne S. aureus isolates. Reference strains, including both methicillin-sensitive and methicillin-resistant S. aureus, were used to evaluate and optimize assay performance. With the newly designed ID16 LAMP primer set, the detection limit for mecA was 15 fg/L of total genomic DNA, equivalent to 5 copies/L, and the assay turnaround time was only 25 min. All mecA-positive isolates identified by conventional qPCR were successfully detected by the LAMP assay. Overall, the developed LAMP method provides a rapid, highly specific, and sensitive alternative for mecA detection.
Related
- Highly sensitive and specific detection of aminoglycoside resistance methylase gene armA by multiple cross displacement amplification-CRISPR/Cas12a technique
- Detection of Plasmodium vivax and Plasmodium falciparum using colorimetric loop-mediated isothermal amplification from dried blood spots collected in active and passive malaria surveillance in the Peruvian Amazon
- A Duplex Isothermal RPA–Lateral Flow Platform for Concurrent Detection of Staphylococcus Aureus and mecA-Mediated Methicillin Resistance
- Electricity Free LAMP: A Protocol for Loop-Mediated Isothermal Amplification Using an Exothermic Chemical Reaction and Lyophilized Reagents
- Molecular Detection Technologies for Helicobacter pylori Antibiotic Resistance: Current Status and Clinical Implications.
BibTeX
@misc{baldenweck2026rapid,
title = {{A rapid and sensitive Loop-Mediated Isothermal Amplification (LAMP) assay for detection of mecA antibiotic resistance gene in clinical and food bacterial isolates}},
author = {L. Baldenweck and M. Djisalov and D. Pinamonti and M. manzano and I. Gadjanski and J. Vidic},
howpublished = {medRxiv},
year = {2026},
month = nov,
doi = {10.64898/2026.11.13.26367169},
url = {https://www.medrxiv.org/content/10.64898/2026.11.13.26367169v1},
note = {CC BY},
}
RIS
TY - UNPB
TI - A rapid and sensitive Loop-Mediated Isothermal Amplification (LAMP) assay for detection of mecA antibiotic resistance gene in clinical and food bacterial isolates
AU - L. Baldenweck
AU - M. Djisalov
AU - D. Pinamonti
AU - M. manzano
AU - I. Gadjanski
AU - J. Vidic
PY - 2026
DA - 2026/11/13
PB - medRxiv
DO - 10.64898/2026.11.13.26367169
UR - https://www.medrxiv.org/content/10.64898/2026.11.13.26367169v1
AB - An advanced LAMP assay targeting the mecA gene in methicillin-resistant Staphylococcus aureus (MRSA) was developed and validated using clinical and foodborne S. aureus isolates. Reference strains, including both methicillin-sensitive and methicillin-resistant S. aureus, were used to evaluate and optimize assay performance. With the newly designed ID16 LAMP primer set, the detection limit for mecA was 15 fg/L of total genomic DNA, equivalent to 5 copies/L, and the assay turnaround time was only 25 min. All mecA-positive isolates identified by conventional qPCR were successfully detected by the LAMP assay. Overall, the developed LAMP method provides a rapid, highly specific, and sensitive alternative for mecA detection.
ER -