Toward Clinically Feasible Assessment of Muscle Mass: Validation of a Seated Bioelectrical Impedance Device Against Dual-Energy X-Ray Absorptiometry (DXA) in Older Adults

Abstract

What are the main findings?• A seated bioelectrical impedance sensor accurately estimated appendicular muscle mass against DXA in older adults. • The Sergi prediction equation provided higher agreement and lower estimation error than the Kyle equation.

What are the implications of the main findings?

• Seated bioelectrical impedance enables rapid, practical muscle mass assessment without compromising measurement validity. • The phase angle derived from the sensor provides complementary information on muscle function and sarcopenia.

Related

  1. Agreement of Bioelectrical Impedance Analysis Prediction Equations with Dual-Energy X-Ray Absorptiometry for Tracking Resistance Training-Induced Changes in Fat-Free Mass in Older Women.
    Alex S Ribeiro, André N S Cahebo, Amilton T Canguali +9
    Sports (Basel, Switzerland)Peer-reviewedCC BYFull textPhysiologyEurope PMC
  2. Bioelectrical Impedance Analysis–Derived Phase Angle in Initial Medical and Nursing Assessment for Cardiac Rehabilitation: Association with Cardiac Rehabilitation Risk Category and Longitudinal Change During the Program—An Exploratory Prospective Observational Study
    Francisco José Rodríguez-Velasco, José Alberto Becerra-Mejías, Luis Miguel Lara-Godoy +3
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  3. Missing Link between Glycemic Control and Bioelectrical Impedance Analysis
    Akinori Higaki
    Internal MedicinePeer-reviewedCC BY-NC-NDFull textPhysiologyJ-STAGE
  4. Bioelectrical impedance-derived body composition and systemic therapy outcomes in non-small cell lung cancer
    Xin Zheng, Rui Gao, Boao Jiang +11
    Translational Lung Cancer ResearchPeer-reviewedCC BY-NC-NDFull textOncologyEurope PMC
  5. Association of electrical properties of bioelectrical impedance spectroscopy with sedentary time, physical activity and muscle function in older adults
    Murad H. Taani, Kimberly D. Bassindale, Yosuke Yamada +2
    BMC Public HealthPeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
BibTeX
@article{piche2026toward,
  title = {{Toward Clinically Feasible Assessment of Muscle Mass: Validation of a Seated Bioelectrical Impedance Device Against Dual-Energy X-Ray Absorptiometry (DXA) in Older Adults}},
  author = {Elodie Piche and Emeline Michel and Olivier Guerin and Etienne Gouraud and Frédéric Chorin},
  journal = {Sensors},
  year = {2026},
  month = aug,
  doi = {10.3390/s26165112},
  url = {https://hal.science/hal-05733600v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Toward Clinically Feasible Assessment of Muscle Mass: Validation of a Seated Bioelectrical Impedance Device Against Dual-Energy X-Ray Absorptiometry (DXA) in Older Adults
AU  - Elodie Piche
AU  - Emeline Michel
AU  - Olivier Guerin
AU  - Etienne Gouraud
AU  - Frédéric Chorin
PY  - 2026
DA  - 2026/08/12
JO  - Sensors
DO  - 10.3390/s26165112
UR  - https://hal.science/hal-05733600v1
AB  - What are the main findings?• A seated bioelectrical impedance sensor accurately estimated appendicular muscle mass against DXA in older adults. • The Sergi prediction equation provided higher agreement and lower estimation error than the Kyle equation.  What are the implications of the main findings?  • Seated bioelectrical impedance enables rapid, practical muscle mass assessment without compromising measurement validity. • The phase angle derived from the sensor provides complementary information on muscle function and sarcopenia.
SN  - 1424-8220
ER  -