Perioperative shear wave elastography for the evaluation of spinal cord release in pediatric dysraphism: first experience in 21 patients
Abstract
OBJECTIVE Shear wave elastography (SWE) is a recent method for evaluating soft tissue stiffness. Its application to the spinal cord is limited by the ultrasound bone barrier. Spinal dysraphism can cause neurological symptoms impairing bladder, bowel, and lower limb function due to a mechanical stress known as tethered cord syndrome. Detethering of the spinal cord is a part of surgical treatment. This study aimed to assess the feasibility of intraoperative elastography to guide surgery in patients with spinal dysraphism involving traction of the spinal cord. METHODS This single-center retrospective study included all patients who underwent surgery for spinal dysraphism between November 2023 and July 2024. SWE was performed under general anesthesia with the patient in the prone position before and after spinal cord detethering. All SWE measurements were performed using the Aixplorer system. Demographic, clinical, and radiological data (age at surgery, neurological status, and MRI findings) were collected. RESULTS Twenty-one patients with a mean ± SD (range) age of 3.7 ± 5.3 (0--17.5) years were included. Etiologies included open saccular dysraphism (n = 3), spinal cord conus lipoma (n = 6), limited dorsal myeloschisis (n = 3), and fibrolipomatous filum (n = 9). In 85% of patients, at least 1 clip was of sufficient quality for analysis both before and after release. The mean ± SD (range) spinal cord stiffness at the beginning of surgery was 25.2 ± 9.2 (12.3--39.1) kPa and 11.2 ± 3.8 (6.2--16.5) kPa at the end of release, with a significant stiffness decrease (p = 0.018). No complications attributable to SWE were observed. CONCLUSIONS SWE of the spinal cord in patients with spinal dysraphism is a safe and feasible imaging method. This technique may assist in assessing the adequacy of untethering during surgery. However, no established normative SWE values for the pediatric spinal cord currently exist. Until it does, the intraoperative interpretability and clinical utility of this technique remain limited.
Related
- Design and Initial Evaluation of a Photovoltaics-focused Course-based Undergraduate Research Experience in Physics
- Reporting treatment planning, delivery, and dose evaluation for 3‐dimensional MLC‐based SFRT: A single institutional clinical experience
- Rotational elastography: six degree-of-freedom seismology in soft tissues measures local elasticity with diffuse fields
- Operator-Informed Gaussian Processes for Complex Helmholtz Wavefields: From Synthetic Benchmarks to In Vivo Brain Elastography
- Ghostly Noise: a Sensorimotor Model for the Ouija Experience
BibTeX
@misc{gaume2026perioperative,
title = {{Perioperative shear wave elastography for the evaluation of spinal cord release in pediatric dysraphism: first experience in 21 patients}},
author = {Mathilde Gaume and Lou Richard and Claudio Vergari and Eleonore Blondiaux and Marius Buffard and Raphael Vialle and Timothée de Saint-Denis},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.04746},
eprint = {2611.04746},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.04746},
}
RIS
TY - UNPB
TI - Perioperative shear wave elastography for the evaluation of spinal cord release in pediatric dysraphism: first experience in 21 patients
AU - Mathilde Gaume
AU - Lou Richard
AU - Claudio Vergari
AU - Eleonore Blondiaux
AU - Marius Buffard
AU - Raphael Vialle
AU - Timoth{é}e de Saint-Denis
PY - 2026
DA - 2026/11/03
PB - arXiv
DO - 10.48550/arxiv.2611.04746
UR - https://arxiv.org/abs/2611.04746
AB - OBJECTIVE Shear wave elastography (SWE) is a recent method for evaluating soft tissue stiffness. Its application to the spinal cord is limited by the ultrasound bone barrier. Spinal dysraphism can cause neurological symptoms impairing bladder, bowel, and lower limb function due to a mechanical stress known as tethered cord syndrome. Detethering of the spinal cord is a part of surgical treatment. This study aimed to assess the feasibility of intraoperative elastography to guide surgery in patients with spinal dysraphism involving traction of the spinal cord. METHODS This single-center retrospective study included all patients who underwent surgery for spinal dysraphism between November 2023 and July 2024. SWE was performed under general anesthesia with the patient in the prone position before and after spinal cord detethering. All SWE measurements were performed using the Aixplorer system. Demographic, clinical, and radiological data (age at surgery, neurological status, and MRI findings) were collected. RESULTS Twenty-one patients with a mean ± SD (range) age of 3.7 ± 5.3 (0--17.5) years were included. Etiologies included open saccular dysraphism (n = 3), spinal cord conus lipoma (n = 6), limited dorsal myeloschisis (n = 3), and fibrolipomatous filum (n = 9). In 85% of patients, at least 1 clip was of sufficient quality for analysis both before and after release. The mean ± SD (range) spinal cord stiffness at the beginning of surgery was 25.2 ± 9.2 (12.3--39.1) kPa and 11.2 ± 3.8 (6.2--16.5) kPa at the end of release, with a significant stiffness decrease (p = 0.018). No complications attributable to SWE were observed. CONCLUSIONS SWE of the spinal cord in patients with spinal dysraphism is a safe and feasible imaging method. This technique may assist in assessing the adequacy of untethering during surgery. However, no established normative SWE values for the pediatric spinal cord currently exist. Until it does, the intraoperative interpretability and clinical utility of this technique remain limited.
ER -