Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 6 min ago
Peer-reviewedCC BY-NC-NDThe American journal of case reports

Extracting the Unexpected: A 35-mm Curved Nail as an Intraocular Foreign Body.

  1. 1Department of Ophthalmology, Ministry of Health, Ohud Hospital, Medina, Saudi Arabia.

Abstract

BACKGROUND Management of posterior segment intraocular foreign bodies is challenging, requiring the preservation of ocular integrity and restoring vision. Traumatic endophthalmitis occurs in 7% to 13% of penetrating injuries, particularly with coexisting intraocular foreign bodies. Managing posterior segment intraocular foreign bodies poses significant challenges due to their complex clinical presentation and the need to achieve multiple goals during treatment. This unusual case of a large metallic intraocular foreign body associated with traumatic cataract, retinal detachment, and endophthalmitis underscores the challenges of diagnosis and management. CASE REPORT A 31-year-old man presented with pain and vision loss in the left eye 7 days after penetrating trauma by a metallic foreign body. Examination showed visual acuity 20/20 (logMAR 0.00) in the right eye and hand movement (logMAR 3) in the left. There was a full-thickness inferior 2-mm corneal laceration with iris incarceration, anterior chamber reaction with fibrinous exudation, and a traumatic cataract, with no retinal view. Imaging confirmed the presence of an intraocular foreign body and endophthalmitis with an associated rhegmatogenous retinal detachment at the time of vitrectomy. The 35-mm foreign body was successfully removed. However, the intraocular foreign body was not detected initially on B-scan ultrasonography, reflecting the diagnostic and therapeutic challenges, as well as the importance of computed tomography imaging. CONCLUSIONS This case report highlights the complexity of managing a large retained intraocular foreign body, underscoring the rarity of its size, complicated by endophthalmitis, traumatic cataract, and rhegmatogenous retinal detachment, emphasizing the importance of multimodal imaging, individualized treatment approaches, and continued research to improve management of similar conditions.

Related

  1. Leaning tower of the retina: A decade-old encapsulated intraocular foreign body.
    Ryuya Hashimoto
    American journal of ophthalmology case reportsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Glass intraocular foreign body removal assisted by biological amniotic membrane: a case report
    Kejie Mao, Zhenquan Zhao, Wenlong Wei +1
    BMC OphthalmologyPeer-reviewedCC BYFull textGeneral medicineDOAJ
  3. Matrix-preserving partial nail resection guided by a spike-like proximal nail plate for ingrown toenails: A 2-center retrospective case series
    Yuto Yamamura, Kazuyasu Fujii, Maiko Kato +2
    JAAD InternationalPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  4. Resolution of Nail Abnormalities in Psoriatic Arthritis
    Tomohiro Sugimoto
    Internal MedicinePeer-reviewedCC BY-NC-NDFull textGeneral medicineJ-STAGE
  5. Lived experiences and occupational pressures among Vietnamese nail salon workers in Maryland
    K. K. Nguyen, E. M. Agree
    medRxivPreprintAll rights reservedFull textEpidemiology & public healthmedRxiv
BibTeX
@article{afandi2026extracting,
  title = {{Extracting the Unexpected: A 35-mm Curved Nail as an Intraocular Foreign Body.}},
  author = {Rahaf A Afandi and Najla A Hafeezullah and Maher A Aljohani and Adel S Alahmadi},
  journal = {The American journal of case reports},
  year = {2026},
  month = oct,
  doi = {10.12659/ajcr.953181},
  url = {https://europepmc.org/article/MED/42860706},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Extracting the Unexpected: A 35-mm Curved Nail as an Intraocular Foreign Body.
AU  - Rahaf A Afandi
AU  - Najla A Hafeezullah
AU  - Maher A Aljohani
AU  - Adel S Alahmadi
PY  - 2026
DA  - 2026/10/12
JO  - The American journal of case reports
DO  - 10.12659/ajcr.953181
UR  - https://europepmc.org/article/MED/42860706
AB  - BACKGROUND Management of posterior segment intraocular foreign bodies is challenging, requiring the preservation of ocular integrity and restoring vision. Traumatic endophthalmitis occurs in 7% to 13% of penetrating injuries, particularly with coexisting intraocular foreign bodies. Managing posterior segment intraocular foreign bodies poses significant challenges due to their complex clinical presentation and the need to achieve multiple goals during treatment. This unusual case of a large metallic intraocular foreign body associated with traumatic cataract, retinal detachment, and endophthalmitis underscores the challenges of diagnosis and management. CASE REPORT A 31-year-old man presented with pain and vision loss in the left eye 7 days after penetrating trauma by a metallic foreign body. Examination showed visual acuity 20/20 (logMAR 0.00) in the right eye and hand movement (logMAR 3) in the left. There was a full-thickness inferior 2-mm corneal laceration with iris incarceration, anterior chamber reaction with fibrinous exudation, and a traumatic cataract, with no retinal view. Imaging confirmed the presence of an intraocular foreign body and endophthalmitis with an associated rhegmatogenous retinal detachment at the time of vitrectomy. The 35-mm foreign body was successfully removed. However, the intraocular foreign body was not detected initially on B-scan ultrasonography, reflecting the diagnostic and therapeutic challenges, as well as the importance of computed tomography imaging. CONCLUSIONS This case report highlights the complexity of managing a large retained intraocular foreign body, underscoring the rarity of its size, complicated by endophthalmitis, traumatic cataract, and rhegmatogenous retinal detachment, emphasizing the importance of multimodal imaging, individualized treatment approaches, and continued research to improve management of similar conditions.
SN  - 1941-5923
ER  -