Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated just now
Peer-reviewedCC BY-NC-NDAmerican journal of ophthalmology case reports

Leaning tower of the retina: A decade-old encapsulated intraocular foreign body.

  1. 1Department of Ophthalmology, Toho University Sakura Medical Center, Chiba, Japan.

Abstract

To report a rare case of dense fibrotic encapsulation surrounding a ferrous intraocular foreign body (IOFB) retained for over a decade, with minimal overt clinical signs of siderosis but retinal dysfunction detected by full-field electroretinography (ERG). A 31-year-old man presented with visual acuity of hand motion 10 years after metallic ocular trauma. Slit-lamp examination and B-scan ultrasonography revealed a luxated hypermature lens and a unique, vertical "leaning tower"-like fibrotic mass adjacent to the lens. Vitrectomy was performed to remove the lens and the encapsulated mass. The content of the fibrotic capsule was confirmed to be oxidized iron fragments. Despite the long-term retention of ferrous material, the patient exhibited no overt clinical signs of siderosis bulbi, such as iris heterochromia or retinal degeneration. Postoperatively, visual acuity improved to 20/100, and optical coherence tomography showed preserved outer retinal layers and no macular edema. However, full-field ERG demonstrated markedly reduced flash a- and b-wave amplitudes and a severely reduced 30-Hz flicker response in the affected eye. Dense fibrotic encapsulation may mitigate overt clinical siderosis in eyes with long-standing ferrous IOFBs, but it does not necessarily prevent retinal dysfunction. Full-field ERG may be important for functional assessment even when clinical signs of siderosis are minimal and retinal anatomy appears relatively preserved.

Related

  1. Glass intraocular foreign body removal assisted by biological amniotic membrane: a case report
    Kejie Mao, Zhenquan Zhao, Wenlong Wei +1
    BMC OphthalmologyPeer-reviewedCC BYFull textGeneral medicineDOAJ
  2. A Study on Secondary Subfertility Caused by a Retained Intrauterine Foreign Body: Unveiling a Decade-Long Clinical Enigma.
    Palwasha Hashim, Kaniz Zehra Naqvi
    Pakistan Journal of Medicine and DentistryPeer-reviewedCC BYFull textGeneral biochemistryPharmacology & toxicologyDOAJ
  3. Extracting the Unexpected: A 35-mm Curved Nail as an Intraocular Foreign Body.
    Rahaf A Afandi, Najla A Hafeezullah, Maher A Aljohani +1
    The American journal of case reportsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Readability of Retina Patient Education Materials Generated With a Large Language Model
    Turner D. Wibbelsman, Martin Calotti, Randy Calotti +7
    Journal of Vitreoretinal DiseasesPeer-reviewedLicence not statedFull text1 citedGeneral medicinePMC
  5. GeoMx Digital Spatial Profiler Enables Layer-Specific Spatial Transcriptomic Profiling of the Human Retina: A Proof-of-Concept Study from Post-Coronovirus Disease 2019 Donor Tissue
    Vijay K. Jidigam, Mala Upadhyay, Wei Yang +2
    Ophthalmology sciencePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{hashimoto2026leaning,
  title = {{Leaning tower of the retina: A decade-old encapsulated intraocular foreign body.}},
  author = {Ryuya Hashimoto},
  journal = {American journal of ophthalmology case reports},
  year = {2026},
  month = oct,
  doi = {10.1016/j.ajoc.2026.102704},
  url = {https://europepmc.org/article/MED/42997563},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Leaning tower of the retina: A decade-old encapsulated intraocular foreign body.
AU  - Ryuya Hashimoto
PY  - 2026
DA  - 2026/10/26
JO  - American journal of ophthalmology case reports
DO  - 10.1016/j.ajoc.2026.102704
UR  - https://europepmc.org/article/MED/42997563
AB  - To report a rare case of dense fibrotic encapsulation surrounding a ferrous intraocular foreign body (IOFB) retained for over a decade, with minimal overt clinical signs of siderosis but retinal dysfunction detected by full-field electroretinography (ERG). A 31-year-old man presented with visual acuity of hand motion 10 years after metallic ocular trauma. Slit-lamp examination and B-scan ultrasonography revealed a luxated hypermature lens and a unique, vertical "leaning tower"-like fibrotic mass adjacent to the lens. Vitrectomy was performed to remove the lens and the encapsulated mass. The content of the fibrotic capsule was confirmed to be oxidized iron fragments. Despite the long-term retention of ferrous material, the patient exhibited no overt clinical signs of siderosis bulbi, such as iris heterochromia or retinal degeneration. Postoperatively, visual acuity improved to 20/100, and optical coherence tomography showed preserved outer retinal layers and no macular edema. However, full-field ERG demonstrated markedly reduced flash a- and b-wave amplitudes and a severely reduced 30-Hz flicker response in the affected eye. Dense fibrotic encapsulation may mitigate overt clinical siderosis in eyes with long-standing ferrous IOFBs, but it does not necessarily prevent retinal dysfunction. Full-field ERG may be important for functional assessment even when clinical signs of siderosis are minimal and retinal anatomy appears relatively preserved.
SN  - 2451-9936
ER  -