Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BY 4.0European Geriatric Medicine

Usability and feasibility of a wearable sensor-based monitoring system providing feedback on sedentary behaviour during inpatient and home-based geriatric rehabilitation

9 affiliations
  1. 1Department of Public Health and Primary Care, Leiden University Medical Center, Leiden, The Netherlands
  2. 2University Network for the Care Sector South-Holland, Leiden University Medical Center, Leiden, The Netherlands
  3. 3Department of Health Services Research, Faculty of Health Medicine and Life Sciences, CAPHRI Care and Public Health Research Institute, Maastricht University, Maastricht, The Netherlands
  4. 4Limburg Living Lab in Ageing and Long-Term Care, Maastricht University, Maastricht, The Netherlands
  5. 5Department of Medicine for Older People, Amsterdam University Medical Center, Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
  6. 6Amsterdam Public Health, Ageing & Later Life, Amsterdam, The Netherlands
  7. 7Amsterdam University of Applied Sciences, Research Group Occupational Therapy: Technology and Participation, Faculty of Health, Centre of Expertise Urban Vitality, Amsterdam, The Netherlands
  8. 8University Network of Organizations for Care for Older Adults, Amsterdam University Medical Center, Amsterdam, The Netherlands
  9. 9National eHealth Living Lab, Leiden, The Netherlands

Abstract

Objective: This study explored the usability and feasibility of a sensor-based monitoring system that provides feedback on sedentary behaviour during inpatient and home-based geriatric rehabilitation from the perspectives of patients and healthcare professionals.

Methods: This mixed-methods study, which is part of the Better@Home study, included a focus group with care professionals, patient surveys, and collection of activity data (e.g. sedentary time and bout duration) via a wearable sensor monitoring system. Usability was assessed qualitatively, while feasibility was assessed using both qualitative data and quantitative adherence to the monitoring system. Focus group data were analysed using the framework method; other data were analysed descriptively.

Results: Twenty-six patients and nine care professionals participated. Usability was perceived as limited due to challenges on both the technology (e.g. measurement accuracy) and implementation level (e.g. tailored use and added value), which impeded integration into existing workflows. Feasibility was deemed sufficient since adherence levels were high.

Conclusions: From the perspectives of patients and healthcare professionals, a sensor-based monitoring system that provides feedback on sedentary behaviour showed sufficient feasibility and limited usability. To facilitate the integration into existing workflows, measurement accuracy should be improved, and implementation should focus on tailored use that offers a clear added value, in line with patient goals.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s41999-026-01616-6.

Related

  1. Technology-Assisted Rehabilitation Gym for at-home Training (TARGeT) for stroke survivors: A study protocol for evaluating feasibility, safety, usability, clinical benefit, and costs
    Simone Kager, Hsiao-Ju Cheng, Christopher Wee Keong Kuah +25
    PLOS OnePeer-reviewedCC BY 4.0Full textNeuroscienceNeurologyPLOS
  2. Usability, acceptability and feasibility of continuous glucose monitoring among children and adolescents with type 1 diabetes in Kenya
    P. Amolo, L. Mungai, A. K. Karume +6
    medRxivPreprintCC BY-NCFull textEndocrinology & metabolismmedRxiv
  3. Evaluating AI chatbots for providing health advice on occupational sedentary behavior in the workplace
    Jingwei Zhang
    Frontiers in public healthPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCCrossref
  4. Acceptability, Safety and Feasibility of a Sedentary Behaviour Intervention (REACH-SCI) in Individuals with Spinal Cord Injury: A Mixed-Methods Study
    D. L. Cooper, A. Warland, E. Norris +6
    medRxivPreprintCC BYFull textPhysiologymedRxiv
  5. Feasibility, acceptability and usability of InControl web-platform intervention for older adults with chronic musculoskeletal pain: A mixed-methods pilot study protocol
    David Oliveira, Nelson P. Rocha, Anabela G. Silva
    PLOS OnePeer-reviewedCC BY 4.0Full textClinical trials & evidence synthesisPLOS
BibTeX
@article{debeij2026usability,
  title = {{Usability and feasibility of a wearable sensor-based monitoring system providing feedback on sedentary behaviour during inpatient and home-based geriatric rehabilitation}},
  author = {Suzanne M. Debeij and Miriam L. Haaksma and Margot W. M. de Waal and Jolanda C. M. van Haastregt and Margriet C. Pol and Marise J. Kasteleyn and Eléonore F. van Dam van Isselt},
  journal = {European Geriatric Medicine},
  year = {2026},
  month = oct,
  doi = {10.1007/s41999-026-01616-6},
  url = {https://doi.org/10.1007/s41999-026-01616-6},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Usability and feasibility of a wearable sensor-based monitoring system providing feedback on sedentary behaviour during inpatient and home-based geriatric rehabilitation
AU  - Suzanne M. Debeij
AU  - Miriam L. Haaksma
AU  - Margot W. M. de Waal
AU  - Jolanda C. M. van Haastregt
AU  - Margriet C. Pol
AU  - Marise J. Kasteleyn
AU  - Eléonore F. van Dam van Isselt
PY  - 2026
DA  - 2026/10/06
JO  - European Geriatric Medicine
DO  - 10.1007/s41999-026-01616-6
UR  - https://doi.org/10.1007/s41999-026-01616-6
AB  - Objective: This study explored the usability and feasibility of a sensor-based monitoring system that provides feedback on sedentary behaviour during inpatient and home-based geriatric rehabilitation from the perspectives of patients and healthcare professionals.  Methods: This mixed-methods study, which is part of the Better@Home study, included a focus group with care professionals, patient surveys, and collection of activity data (e.g. sedentary time and bout duration) via a wearable sensor monitoring system. Usability was assessed qualitatively, while feasibility was assessed using both qualitative data and quantitative adherence to the monitoring system. Focus group data were analysed using the framework method; other data were analysed descriptively.  Results: Twenty-six patients and nine care professionals participated. Usability was perceived as limited due to challenges on both the technology (e.g. measurement accuracy) and implementation level (e.g. tailored use and added value), which impeded integration into existing workflows. Feasibility was deemed sufficient since adherence levels were high.  Conclusions: From the perspectives of patients and healthcare professionals, a sensor-based monitoring system that provides feedback on sedentary behaviour showed sufficient feasibility and limited usability. To facilitate the integration into existing workflows, measurement accuracy should be improved, and implementation should focus on tailored use that offers a clear added value, in line with patient goals.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s41999-026-01616-6.
SN  - 1878-7649
SN  - 1878-7657
ER  -