Skip to content
DraconiticResearch
Search Sources API
203,952 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BYBiomimetics (Basel, Switzerland)

Multimodal Gait Acquisition and Musculoskeletal Simulation for Subject-Specific Evaluation of Ankle Exosuit Cable Anchor Positioning in Cerebral Palsy.

  1. 1Department of Biomechanical Engineering, University of Twente, 7522 NB Enschede, The Netherlands.
  2. 2Department of Mechanical Engineering, Energy and Materials, University of Extremadura, 06006 Badajoz, Spain.
  3. 3Department of Mechanical Engineering and Manufacturing, Higher Technical School of Engineering, University of Seville, 41092 Seville, Spain.

Abstract

Wearable ankle exosuits require precise evaluation frameworks to optimize assistive force transmission and subject-specific configuration. This study presents a multimodal sensor-based experimental and computational framework to assess the influence of ankle exosuit cable anchor positioning on neuromuscular and energetic responses during gait in a child with spastic hemiplegic cerebral palsy. Three-dimensional kinematics were acquired using an optical motion capture system (12 infrared cameras), while ground reaction forces were recorded through instrumented force plates. Metabolic cost was experimentally measured using portable respiratory gas analysis. These sensor-derived data were integrated into a participant-scaled musculoskeletal model in OpenSim to simulate nine cable anchor configurations and quantify changes in muscle activation, force production, mechanical impulse, and metabolic power. Cable geometry altered the predicted distribution of plantar-flexor loading across configurations. Experimental measurements were not available for muscle-level outputs or for the assisted configurations; therefore, these responses were interpreted as model-derived, exploratory comparisons rather than experimentally validated physiological effects. Configurations with larger offsets from the heel-reference position tended to yield greater reductions in gastrocnemius demand, whereas configurations nearer the heel reference more effectively reduced soleus loading but increased secondary stabilizing muscle recruitment. Predicted metabolic changes across assisted configurations ranged from a 0.86% reduction to a 6.28% increase relative to the experimental baseline, and from a 2.66% reduction to a 4.33% increase relative to the simulated non-actuated condition. These differences should be interpreted as indicators of model sensitivity rather than demonstrated energetic improvements. This study demonstrates how multimodal gait sensing combined with musculoskeletal simulation provides a quantitative tool for preliminary screening of cable-driven ankle exosuit design in pathological gait.

Related

  1. Interferential Current Therapy and Spray-And-Stretch in Musculoskeletal Disorders: A Narrative Review of Mechanisms, Evidence, and Clinical Positioning in the Absence of Direct Comparative Trials.
    Chul Hee Jung, Seok Yeon Choi, Dong Ha Lee
    Bioengineering (Basel, Switzerland)Peer-reviewedCC BYFull textPharmacology & toxicologyEurope PMC
  2. SensorW: Open-Source Wear Operating System Platform for Continuous Global Positioning System and Multimodal Sensor Data Collection in Real-World Settings
    Yichi Yang, Kazushige Ihara, Felipe Alfonso Sandoval Garrido +9
    Sensors (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  3. Three-dimensional finite element simulation study on abnormal magnetic positioning signals inside perforated casing
    Yadong Zhao, Xinghua Qi, Bihong Wang +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCrossref
  4. ESP32-S3-Based Multimodal Wearable for Remote Vital-Sign Acquisition with ECG-to-PPG Pulse-Arrival-Time Tracking and Functional Cloud Triage: An Engineering Proof of Concept
    Mohamed Ali Torad, Hamdy Elsayed Ahmed, Ahmed Ali Mohamed Torad +3
    Sensors (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  5. Diagnostic Musculoskeletal Ultrasound in the Evaluation of the Subacromial Bursa
    International journal of sports physical therapyPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
BibTeX
@article{bermejogarcia2026multimodal,
  title = {{Multimodal Gait Acquisition and Musculoskeletal Simulation for Subject-Specific Evaluation of Ankle Exosuit Cable Anchor Positioning in Cerebral Palsy.}},
  author = {Javier Bermejo-García and Alberto Martín-Fraile and Joaquín Ojeda and Rafael Agujetas and Francisco Javier Alonso Sánchez},
  journal = {Biomimetics (Basel, Switzerland)},
  year = {2026},
  month = oct,
  doi = {10.3390/biomimetics11100731},
  url = {https://europepmc.org/article/MED/42930283},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Multimodal Gait Acquisition and Musculoskeletal Simulation for Subject-Specific Evaluation of Ankle Exosuit Cable Anchor Positioning in Cerebral Palsy.
AU  - Javier Bermejo-García
AU  - Alberto Martín-Fraile
AU  - Joaquín Ojeda
AU  - Rafael Agujetas
AU  - Francisco Javier Alonso Sánchez
PY  - 2026
DA  - 2026/10/13
JO  - Biomimetics (Basel, Switzerland)
DO  - 10.3390/biomimetics11100731
UR  - https://europepmc.org/article/MED/42930283
AB  - Wearable ankle exosuits require precise evaluation frameworks to optimize assistive force transmission and subject-specific configuration. This study presents a multimodal sensor-based experimental and computational framework to assess the influence of ankle exosuit cable anchor positioning on neuromuscular and energetic responses during gait in a child with spastic hemiplegic cerebral palsy. Three-dimensional kinematics were acquired using an optical motion capture system (12 infrared cameras), while ground reaction forces were recorded through instrumented force plates. Metabolic cost was experimentally measured using portable respiratory gas analysis. These sensor-derived data were integrated into a participant-scaled musculoskeletal model in OpenSim to simulate nine cable anchor configurations and quantify changes in muscle activation, force production, mechanical impulse, and metabolic power. Cable geometry altered the predicted distribution of plantar-flexor loading across configurations. Experimental measurements were not available for muscle-level outputs or for the assisted configurations; therefore, these responses were interpreted as model-derived, exploratory comparisons rather than experimentally validated physiological effects. Configurations with larger offsets from the heel-reference position tended to yield greater reductions in gastrocnemius demand, whereas configurations nearer the heel reference more effectively reduced soleus loading but increased secondary stabilizing muscle recruitment. Predicted metabolic changes across assisted configurations ranged from a 0.86% reduction to a 6.28% increase relative to the experimental baseline, and from a 2.66% reduction to a 4.33% increase relative to the simulated non-actuated condition. These differences should be interpreted as indicators of model sensitivity rather than demonstrated energetic improvements. This study demonstrates how multimodal gait sensing combined with musculoskeletal simulation provides a quantitative tool for preliminary screening of cable-driven ankle exosuit design in pathological gait.
SN  - 2313-7673
ER  -