Inter-laboratory study for the quantification of chlordecone in serum samples: design, performance and recommendations
Abstract
Chlordecone (CLD) exposure remains a major concern for the West Indies. Reliable quantification of CLD in human serum samples is required for internal exposure monitoring, particularly at the internal chronic toxicological reference value of 0.4 ng/mL. Trueness is one of the main characteristics of analytical methods which can be assessed using reference materials or through inter-laboratory studies (ILS). Since no commercial reference materials are currently available for our purpose, a network of five qualified laboratories was established. A preliminary study was performed among the co-authors teams of this paper to address several critical points, including the solvent used for CLD standard dilutions, the internal standard selection and recommendations for the sample preparation. Subsequently, an inter-laboratory study was conducted following the guidelines of the ISO 17043:2023 standard, using two serum samples, a human one spiked around 0.4 ng/mL and an incurred animal one diluted to approximately 2 ng/mL. Assigned values, Z-scores and measurement uncertainties were calculated from the results provided by ten participants, yielding Z-scores in-between [−2;+2] in 88% of cases. In parallel, accurate quantification of CLD was achieved using 13C10 labelled standards under isotopic dilution, with calibration performed using solutions in acetone or methyl tert-butyl ether (MTBE). Moreover, both QuEChERS or SPE extraction methods, as well as LC and GC coupled with MS/MS techniques, are recommended for this determination.
Related
- Comparative Analysis of Bird Collision Prevention Patterned Samples: Avoidance Performance Under Transparent and Reflective Glass Conditions in Flight Tunnel Tests
- qPyCR: A qPCR Data Analyzer for Template Quantification and the Detection of Performance Outliers
- Complex-trait dissection with Evolve-and-Resequence: Selection for improved flight performance in laboratory fruit fly populations
- Systematic study of the performance of small robots on controlled laboratory substrates
- Recurrence quantification analysis of the effects of height-induced postural threat and arm movement restriction on balance performance in children and young adults
BibTeX
@article{guiffard2026interlaboratory,
title = {{Inter-laboratory study for the quantification of chlordecone in serum samples: design, performance and recommendations}},
author = {Ingrid Guiffard and Vincent Vaccher and Georges Scholl and Maïlie Saint-Hilaire and Fabien Mercier and Claire Soligot and Agnès Fournier and Vincent Bessonneau and Gauthier Eppe and Emmanuelle Bichon},
journal = {Microchemical Journal},
year = {2026},
month = nov,
doi = {10.1016/j.microc.2026.120210},
url = {https://hal.science/hal-05863577v1},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Inter-laboratory study for the quantification of chlordecone in serum samples: design, performance and recommendations
AU - Ingrid Guiffard
AU - Vincent Vaccher
AU - Georges Scholl
AU - Maïlie Saint-Hilaire
AU - Fabien Mercier
AU - Claire Soligot
AU - Agnès Fournier
AU - Vincent Bessonneau
AU - Gauthier Eppe
AU - Emmanuelle Bichon
PY - 2026
DA - 2026/11/13
JO - Microchemical Journal
DO - 10.1016/j.microc.2026.120210
UR - https://hal.science/hal-05863577v1
AB - Chlordecone (CLD) exposure remains a major concern for the West Indies. Reliable quantification of CLD in human serum samples is required for internal exposure monitoring, particularly at the internal chronic toxicological reference value of 0.4 ng/mL. Trueness is one of the main characteristics of analytical methods which can be assessed using reference materials or through inter-laboratory studies (ILS). Since no commercial reference materials are currently available for our purpose, a network of five qualified laboratories was established. A preliminary study was performed among the co-authors teams of this paper to address several critical points, including the solvent used for CLD standard dilutions, the internal standard selection and recommendations for the sample preparation. Subsequently, an inter-laboratory study was conducted following the guidelines of the ISO 17043:2023 standard, using two serum samples, a human one spiked around 0.4 ng/mL and an incurred animal one diluted to approximately 2 ng/mL. Assigned values, Z-scores and measurement uncertainties were calculated from the results provided by ten participants, yielding Z-scores in-between [−2;+2] in 88% of cases. In parallel, accurate quantification of CLD was achieved using 13C10 labelled standards under isotopic dilution, with calibration performed using solutions in acetone or methyl tert-butyl ether (MTBE). Moreover, both QuEChERS or SPE extraction methods, as well as LC and GC coupled with MS/MS techniques, are recommended for this determination.
SN - 0026-265X
SN - 1095-9149
ER -