Automated CTA-Based Assessment of Aortic Remodeling Through Volumetric Biomarkers in Type B Aortic Dissection
- 1Universita di Pavia
Abstract
Type B aortic dissection (TBAD) requires lifelong morphological monitoring using computed tomography angiography (CTA). TBAD separates blood flow into the true lumen (TL), the original aortic channel, and the false lumen (FL), created by the dissection. Although three-dimensional volumetric analysis may complement diameter-based surveillance, its clinical adoption is limited by the time required for manual segmentation, particularly in postoperative scans affected by metallic artifacts. This study developed and evaluated an automated CTA-based framework for volumetric surveillance of TBAD across native and post-TEVAR conditions. We propose AORTA-SCAN, a hierarchical multi-stage framework for automated segmentation of the aorta, TL, and FL, extended to stented anatomy through a metal-aware triple-input strategy. The system computes conventional diameter measurements and volumetric biomarkers, including the perfusion dissection index (PDI), defined as the ratio between perfused FL volume and total perfused aortic volume. Domain adaptation was achieved using transfer learning and partial-label learning across heterogeneous clinical annotations. In native cases, AORTA-SCAN achieved a global Dice score of 0.84 and significantly improved FL segmentation compared with the nnU-Net baseline (0.84 vs 0.71, p < 0.001). Volumetric analysis showed high agreement with expert references, with a mean PDI bias of -0.17%. In postoperative cases, TL segmentation remained robust (Dice = 0.90), while FL and stent Dice were 0.75 and 0.72, respectively. Processing was completed in less than 1 minute per case on a standard workstation. AORTA-SCAN enables automated volumetric surveillance of TBAD and supports scalable extraction of PDI and diameter biomarkers from native and post-TEVAR CTA.
Related
- 161 Automated Volumetric Analysis in Neuro-Oncology: Institutional Experience and Clinical Utility of AI-Driven Assessment
- EP04.05 Semi-automated MRI-based volumetric assessment of glioblastoma tumor subregions
- Micron-precision depth control in automated volumetric laser ablation with ultrashort laser pulses
- Beyond Mechanical Exclusion: Immune and Cellular Remodeling After Stent-Graft Implantation in Type B Aortic Dissection
- Volumetric analysis and MRI radiomics for response assessment in canine glioma immunotherapy: an exploratory feasibility study
BibTeX
@misc{maccarini2026automated,
title = {{Automated CTA-Based Assessment of Aortic Remodeling Through Volumetric Biomarkers in Type B Aortic Dissection}},
author = {A. Maccarini and M. Ferraresi and A. Molinari and J. Jovanovic and G. Rossi and L. Mainardi and P. Cerveri},
howpublished = {medRxiv},
year = {2026},
month = nov,
doi = {10.64898/2026.11.23.26368738},
url = {https://www.medrxiv.org/content/10.64898/2026.11.23.26368738v1},
note = {CC BY-NC},
}
RIS
TY - UNPB
TI - Automated CTA-Based Assessment of Aortic Remodeling Through Volumetric Biomarkers in Type B Aortic Dissection
AU - A. Maccarini
AU - M. Ferraresi
AU - A. Molinari
AU - J. Jovanovic
AU - G. Rossi
AU - L. Mainardi
AU - P. Cerveri
PY - 2026
DA - 2026/11/23
PB - medRxiv
DO - 10.64898/2026.11.23.26368738
UR - https://www.medrxiv.org/content/10.64898/2026.11.23.26368738v1
AB - Type B aortic dissection (TBAD) requires lifelong morphological monitoring using computed tomography angiography (CTA). TBAD separates blood flow into the true lumen (TL), the original aortic channel, and the false lumen (FL), created by the dissection. Although three-dimensional volumetric analysis may complement diameter-based surveillance, its clinical adoption is limited by the time required for manual segmentation, particularly in postoperative scans affected by metallic artifacts. This study developed and evaluated an automated CTA-based framework for volumetric surveillance of TBAD across native and post-TEVAR conditions. We propose AORTA-SCAN, a hierarchical multi-stage framework for automated segmentation of the aorta, TL, and FL, extended to stented anatomy through a metal-aware triple-input strategy. The system computes conventional diameter measurements and volumetric biomarkers, including the perfusion dissection index (PDI), defined as the ratio between perfused FL volume and total perfused aortic volume. Domain adaptation was achieved using transfer learning and partial-label learning across heterogeneous clinical annotations. In native cases, AORTA-SCAN achieved a global Dice score of 0.84 and significantly improved FL segmentation compared with the nnU-Net baseline (0.84 vs 0.71, p < 0.001). Volumetric analysis showed high agreement with expert references, with a mean PDI bias of -0.17%. In postoperative cases, TL segmentation remained robust (Dice = 0.90), while FL and stent Dice were 0.75 and 0.72, respectively. Processing was completed in less than 1 minute per case on a standard workstation. AORTA-SCAN enables automated volumetric surveillance of TBAD and supports scalable extraction of PDI and diameter biomarkers from native and post-TEVAR CTA.
ER -