Micron-precision depth control in automated volumetric laser ablation with ultrashort laser pulses
Abstract
Achieving “first time right” depth precision in volumetric laser ablation – particularly for deep features exceeding 50 μm – is challenging due to dynamic effects such as incubation-induced changes in ablation efficiency and altered laser-material coupling caused by the formation of Laser-Induced Periodic Surface Structures (LIPSS). This work presents an industrial-grade setup for closed-loop volumetric ablation that integrates an ultrafast laser, a galvanometer scanner, and coaxial Optical Coherence Tomography (OCT) for real-time depth control. To overcome measurement artifacts arising from the evolving surface morphology and local fluctuations of the OCT depth signal, two complementary correction strategies were implemented. First, a morphology-dependent initial OCT depth offset is determined by extrapolating the stabilized depth progression and subsequently compensated. Second, a pixel-wise moving average of the OCT depth measurements provides a robust termination criterion for local laser processing. The developed processing system with the advanced control software enabled precise and reproducible laser ablation of volumetric structures in AISI 304 stainless steel with a depth accuracy of 1 μm to 2 μm regardless of the investigated initial surface states and process parameters for target depths ranging from 50 μm to 500 μm.
Related
- 161 Automated Volumetric Analysis in Neuro-Oncology: Institutional Experience and Clinical Utility of AI-Driven Assessment
- EP04.05 Semi-automated MRI-based volumetric assessment of glioblastoma tumor subregions
- Automated CTA-Based Assessment of Aortic Remodeling Through Volumetric Biomarkers in Type B Aortic Dissection
- Semi-automated CT attenuation measurement for MASLD: volumetric versus peripheral-ROI methods
- Evaluating Precision and Responsiveness of MRI-derived Brain Volumetric and Clinical Outcome Measures in CLN3 Disease
BibTeX
@article{holder2026micronprecision,
title = {{Micron-precision depth control in automated volumetric laser ablation with ultrashort laser pulses}},
author = {Daniel Holder and Matthias Buser and Rudolf Weber and Volkher Onuseit and Thomas Graf},
journal = {Scientific Reports},
year = {2026},
month = nov,
doi = {10.1038/s41598-026-79064-2},
url = {https://www.nature.com/articles/s41598-026-79064-2},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Micron-precision depth control in automated volumetric laser ablation with ultrashort laser pulses
AU - Daniel Holder
AU - Matthias Buser
AU - Rudolf Weber
AU - Volkher Onuseit
AU - Thomas Graf
PY - 2026
DA - 2026/11/15
JO - Scientific Reports
DO - 10.1038/s41598-026-79064-2
UR - https://www.nature.com/articles/s41598-026-79064-2
AB - Achieving “first time right” depth precision in volumetric laser ablation – particularly for deep features exceeding 50 μm – is challenging due to dynamic effects such as incubation-induced changes in ablation efficiency and altered laser-material coupling caused by the formation of Laser-Induced Periodic Surface Structures (LIPSS). This work presents an industrial-grade setup for closed-loop volumetric ablation that integrates an ultrafast laser, a galvanometer scanner, and coaxial Optical Coherence Tomography (OCT) for real-time depth control. To overcome measurement artifacts arising from the evolving surface morphology and local fluctuations of the OCT depth signal, two complementary correction strategies were implemented. First, a morphology-dependent initial OCT depth offset is determined by extrapolating the stabilized depth progression and subsequently compensated. Second, a pixel-wise moving average of the OCT depth measurements provides a robust termination criterion for local laser processing. The developed processing system with the advanced control software enabled precise and reproducible laser ablation of volumetric structures in AISI 304 stainless steel with a depth accuracy of 1 μm to 2 μm regardless of the investigated initial surface states and process parameters for target depths ranging from 50 μm to 500 μm.
SN - 2045-2322
ER -