Skip to content
DraconiticResearch
Search Sources API
194,230 studies31 sourcesUpdated 13 min ago
PreprintCC BY 4.0arXiv

Polyurethane Scintillators for High-Energy Physics Detectors: Optimization, Scale-up, and Radiation Response

Abstract

Plastic scintillators remain attractive for large-area particle detectors because of their fast response, mechanical flexibility, and relatively simple fabrication. Motivated by future applications including the ALICE~3 Muon Identifier (MID) and the upgrade of the ALICE Fast Interaction Trigger (FIT), this work investigates polyurethane (PU)-based plastic scintillators doped with 2,5-diphenyloxazole (PPO) and 1,4-bis(5-phenyloxazol-2-yl)benzene (POPOP). Systematic information on the optimization and radiation response of this material system remains limited. A series of compositions was therefore fabricated and characterized using minimum-ionizing particles (MIP), optical spectroscopy, and time-correlated single-photon counting. The measurements show that the scintillation response is governed primarily by the PPO concentration, while POPOP mainly modifies the spectral response, and fast effective decay times of approximately 1.6--1.75~ns are maintained across the doped samples. The best-performing formulation was subsequently scaled to 20-cm and 1-m scintillator bars and successfully operated with a single embedded wavelength-shifting fiber and SiPM readout, demonstrating its suitability for meter-scale light collection. Proton-irradiation measurements at the CERN IRRAD facility further revealed systematic degradation of the optical and scintillation responses with increasing exposure, together with substantial recovery after approximately two months. These results demonstrate that optimized PU--PPO--POPOP scintillators can combine fast timing, high light output, scalable detector geometry, and recoverable radiation response, supporting their further development for future large-area particle-detector systems.

Related

  1. Perovskite Nanocrystal-Based Scintillators: Synthesis Routes, Matrix Engineering, and Performance Optimization for Radiation Detection
    Pavel M. Sokolov, Aleksandr A. Knysh, Irina S. Aleksandrova +2
    NanomaterialsPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossrefEurope PMC
  2. Absolute calibration of scintillators for laser-driven ion spectroscopy using in situ CR-39 sampling detectors
    Wei Lin, Tzu-Yao Huang, Shih-Fan Yang +9
    arXivPreprintCC BY-NC-ND 4.0Full textApplied physics & instrumentationPlasma physicsarXiv
  3. Response of GAGG(Ce) scintillators to different charged particles
    Kai-Jie Zhou, Zai-Hong Yang, Hooi-Jin Ong +13
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationNuclear physicsarXiv
  4. Characterization of a Resistively Multiplexed SiPM Readout for Position-Sensitive Scintillating Fibre Radiation Detectors.
    Klemen Žagar, Gregor Košir, Matjaž Vencelj +7
    Sensors (Basel, Switzerland)Peer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  5. Improved aluminum film transport properties and enhanced TES response in athermal phonon detectors: implications for quasiparticle dynamics
    Mahdi Mirzakhani, Keith Hunter, Rupak Mahapatra +1
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationHigh-energy & particle physicsarXiv
BibTeX
@misc{laveaga2026polyurethane,
  title = {{Polyurethane Scintillators for High-Energy Physics Detectors: Optimization, Scale-up, and Radiation Response}},
  author = {Rafael Angel Narcio Laveaga and Ildefonso León Monzón and Juan Carlos Cabanillas Noris and Thanh Luan Nguyen and Jan Král and Vítezslav Jarýd and Gerardo Herrera Corral and Vojtech Zabloudil and Etiennette Auffray and Carlos Duarte Galván and Solangel Rojas Torres},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.06500},
  eprint = {2610.06500},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.06500},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Polyurethane Scintillators for High-Energy Physics Detectors: Optimization, Scale-up, and Radiation Response
AU  - Rafael Angel Narcio Laveaga
AU  - Ildefonso León Monzón
AU  - Juan Carlos Cabanillas Noris
AU  - Thanh Luan Nguyen
AU  - Jan Král
AU  - Vítezslav Jarýd
AU  - Gerardo Herrera Corral
AU  - Vojtech Zabloudil
AU  - Etiennette Auffray
AU  - Carlos Duarte Galván
AU  - Solangel Rojas Torres
PY  - 2026
DA  - 2026/10/05
PB  - arXiv
DO  - 10.48550/arxiv.2610.06500
UR  - https://arxiv.org/abs/2610.06500
AB  - Plastic scintillators remain attractive for large-area particle detectors because of their fast response, mechanical flexibility, and relatively simple fabrication. Motivated by future applications including the ALICE~3 Muon Identifier (MID) and the upgrade of the ALICE Fast Interaction Trigger (FIT), this work investigates polyurethane (PU)-based plastic scintillators doped with 2,5-diphenyloxazole (PPO) and 1,4-bis(5-phenyloxazol-2-yl)benzene (POPOP). Systematic information on the optimization and radiation response of this material system remains limited. A series of compositions was therefore fabricated and characterized using minimum-ionizing particles (MIP), optical spectroscopy, and time-correlated single-photon counting. The measurements show that the scintillation response is governed primarily by the PPO concentration, while POPOP mainly modifies the spectral response, and fast effective decay times of approximately 1.6--1.75~ns are maintained across the doped samples. The best-performing formulation was subsequently scaled to 20-cm and 1-m scintillator bars and successfully operated with a single embedded wavelength-shifting fiber and SiPM readout, demonstrating its suitability for meter-scale light collection. Proton-irradiation measurements at the CERN IRRAD facility further revealed systematic degradation of the optical and scintillation responses with increasing exposure, together with substantial recovery after approximately two months. These results demonstrate that optimized PU--PPO--POPOP scintillators can combine fast timing, high light output, scalable detector geometry, and recoverable radiation response, supporting their further development for future large-area particle-detector systems.
ER  -