Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 50 min ago
PreprintCC BY-NC-ND 4.0arXiv

Absolute calibration of scintillators for laser-driven ion spectroscopy using in situ CR-39 sampling detectors

Abstract

Quantitative studies of laser-driven ion acceleration and laser-induced nuclear fusion require accurate measurements of ion yields and energy spectra. Although scintillator screens integrated with Thomson parabola spectrometers provide real-time diagnostics, their nonlinear scintillation response requires absolute calibration. We present an in situ, single-shot cross-calibration method using a 2-mm-period CR-39 sampling mask to simultaneously record particle counts and scintillation signals from laser-accelerated proton beams. The method is applied to calibrate a 400-μm-thick CsI:Tl crystal and a 6-μm-thick P43 phosphor screen over a broad proton energy range. The measured scintillation responses are compared with a theoretical model combining Birks' law and simulated proton stopping powers. The calibration quantitatively reveals the distinct response characteristics of the two scintillators, including thickness-dependent punch-through effects and constraints on ionization quenching, and demonstrates a practical approach for the absolute calibration of scintillator screens used in laser-driven ion spectroscopy.

Related

  1. Polyurethane Scintillators for High-Energy Physics Detectors: Optimization, Scale-up, and Radiation Response
    Rafael Angel Narcio Laveaga, Ildefonso León Monzón, Juan Carlos Cabanillas Noris +8
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  2. Photon Calibration Techniques for High Resolution Cryogenic Detectors
    William J. Matava, Michael R. Williams
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationComputational physicsarXiv
  3. Clock-noise propagation and calibration for phase-locking configurations in space-based gravitational-wave detectors
    Pan-Pan Wang, Cheng-Gang Shao
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsGravitation & general relativityarXiv
  4. Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB
    M. F. Albakry, I. Alkhatib, D. Alonso-González +141
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  5. The James Webb Space Telescope Absolute Flux Calibration. VI. Near-infrared Camera Imaging and Coronagraphy
    Martha L. Boyer, Benjamin Sunnquist, Bryan Hilbert +4
    The Astronomical JournalPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossref
BibTeX
@misc{lin2026absolute,
  title = {{Absolute calibration of scintillators for laser-driven ion spectroscopy using in situ CR-39 sampling detectors}},
  author = {Wei Lin and Tzu-Yao Huang and Shih-Fan Yang and Shih-Wei Wang and Kuo-Yu Hsiao and Chun-Han Chen and Yan-Syu Liu and Jun-Yi Chen and Ya-Po Yang and Chen-Kang Huang and Hsu-hsin Chu and Chih-Hao Pai},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.38063},
  eprint = {2610.38063},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.38063},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - UNPB
TI  - Absolute calibration of scintillators for laser-driven ion spectroscopy using in situ CR-39 sampling detectors
AU  - Wei Lin
AU  - Tzu-Yao Huang
AU  - Shih-Fan Yang
AU  - Shih-Wei Wang
AU  - Kuo-Yu Hsiao
AU  - Chun-Han Chen
AU  - Yan-Syu Liu
AU  - Jun-Yi Chen
AU  - Ya-Po Yang
AU  - Chen-Kang Huang
AU  - Hsu-hsin Chu
AU  - Chih-Hao Pai
PY  - 2026
DA  - 2026/10/27
PB  - arXiv
DO  - 10.48550/arxiv.2610.38063
UR  - https://arxiv.org/abs/2610.38063
AB  - Quantitative studies of laser-driven ion acceleration and laser-induced nuclear fusion require accurate measurements of ion yields and energy spectra. Although scintillator screens integrated with Thomson parabola spectrometers provide real-time diagnostics, their nonlinear scintillation response requires absolute calibration. We present an in situ, single-shot cross-calibration method using a 2-mm-period CR-39 sampling mask to simultaneously record particle counts and scintillation signals from laser-accelerated proton beams. The method is applied to calibrate a 400-μm-thick CsI:Tl crystal and a 6-μm-thick P43 phosphor screen over a broad proton energy range. The measured scintillation responses are compared with a theoretical model combining Birks' law and simulated proton stopping powers. The calibration quantitatively reveals the distinct response characteristics of the two scintillators, including thickness-dependent punch-through effects and constraints on ionization quenching, and demonstrates a practical approach for the absolute calibration of scintillator screens used in laser-driven ion spectroscopy.
ER  -