Skip to content
DraconiticResearch
Search Sources API
181,713 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BY-NC-NDCurrent Directions in Biomedical Engineering

An Open-Source Simulation Model of a Medical Oxygen Concentrator

  1. 1Technische Hochschule Ulm, Albert-Einstein-Allee 55, 89081Ulm, Germany

Abstract

This work presents an open-source dynamic model of a pressure swing adsorption (PSA)-based medical oxygen concentrator, enabling a systematic investigation of its process behavior. The model describes the coupled interaction of the compressor, adsorption columns, valves, and auxiliary volumes, and is based on a one-dimensional isothermal formulation including mass transfer, adsorption kinetics, and pressure drop. The governing equations are discretized using a finite volume approach and numerically solved in MATLAB. Simulation results are compared with experimental data from a commercial oxygen concentrator. The model captures the main characteristics of the PSA process. Deviations from experimental data are mainly observed during transient phases, while the model accurately reproduces the cyclic steady-state behavior. The developed model provides a basis for the analysis of operating parameters and for the assessment of the energy efficiency of PSA-based oxygen concentrators.

Related

  1. Trends and Heterogeneity in Having a Usual Source of Care Among U.S. Children: Evidence from the Medical Expenditure Panel Survey, 2015-2024
    B. Han, B. Feng, C. Zhao +2
    medRxivPreprintAll rights reservedFull textObstetrics, gynaecology & paediatricsmedRxiv
  2. Localized Debriefing Assessment for Simulation in Healthcare (DASH): Medical Student Engagement and Debriefing Assessment Validity
    Taylor Ho, Brent Shimoda, Kyle Ishikawa +2
    Medical Science EducatorPeer-reviewedLicence not statedFull textPhysiologyPMC
  3. Virtual Operating Theatre Simulation: Development and Evaluation of a Web-Based Learning Tool for Medical Students
    Thiruselvi Subramaniam, Chew Fei Sow, Siti Azreena Binti Mubin +1
    Medical Science EducatorPeer-reviewedLicence not statedFull textPhysiologyPMC
  4. Post In-Hospital Cardiac Arrest Simulation to Improve Medical Decision Making and Communication in Internal Medicine Residents
    Emily Harris, Alexandra Collis, David Carlbom +3
    MedEdPORTAL : the journal of teaching and learning resourcesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Association Between Structured Obstetric Simulation and OSCE Performance in Undergraduate Medical Students
    Rosa Patricia Cruz-Nieves, Angela Leticia Zambrano-Gutiérrez, Paulina Guadalupe Briseño-Sahagun +3
    Medical Science EducatorPeer-reviewedLicence not statedFull textPhysiologyPMC
BibTeX
@article{maximilian2026opensource,
  title = {{An Open-Source Simulation Model of a Medical Oxygen Concentrator}},
  author = {Jester-Zürker Maximilian and Peuscher Heiko},
  journal = {Current Directions in Biomedical Engineering},
  year = {2026},
  month = oct,
  doi = {10.1515/cdbme-2026-0158},
  url = {https://doi.org/10.1515/cdbme-2026-0158},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - An Open-Source Simulation Model of a Medical Oxygen Concentrator
AU  - Jester-Zürker Maximilian
AU  - Peuscher Heiko
PY  - 2026
DA  - 2026/10/26
JO  - Current Directions in Biomedical Engineering
DO  - 10.1515/cdbme-2026-0158
UR  - https://doi.org/10.1515/cdbme-2026-0158
AB  - This work presents an open-source dynamic model of a pressure swing adsorption (PSA)-based medical oxygen concentrator, enabling a systematic investigation of its process behavior. The model describes the coupled interaction of the compressor, adsorption columns, valves, and auxiliary volumes, and is based on a one-dimensional isothermal formulation including mass transfer, adsorption kinetics, and pressure drop. The governing equations are discretized using a finite volume approach and numerically solved in MATLAB. Simulation results are compared with experimental data from a commercial oxygen concentrator. The model captures the main characteristics of the PSA process. Deviations from experimental data are mainly observed during transient phases, while the model accurately reproduces the cyclic steady-state behavior. The developed model provides a basis for the analysis of operating parameters and for the assessment of the energy efficiency of PSA-based oxygen concentrators.
SN  - 2364-5504
ER  -