Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BY-NCNanoscale advances

Copper oxide nanoparticle/stainless steel hybrid structures for non-enzymatic glucose detection

5 affiliations
  1. 1Center for Semiconductor Components and Nanotechnologies, Universidade Estadual de Campinas Campinas SP 13083-870 Brazil [email protected].
  2. 2Department of Physical Chemistry, Institute of Chemistry, Federal University of Bahia Salvador Bahia 40170-115 Brazil.
  3. 3Instituto de Química, Universidade Estadual de Campinas SP 13083-862 Brazil.
  4. 4Department of Hardware and Microelectronics, Instituto de Pesquisas Eldorado Campinas SP 13083-898 Brazil.
  5. 5Faculty of Electrical and Computer Engineering, Universidade Estadual de Campinas Campinas SP 13083-852 Brazil.

Abstract

The global prevalence of diabetes necessitates the development of cost-effective, durable, high-performance platforms for glucose monitoring. In this work, a flexible hybrid architecture for non-enzymatic glucose sensing is reported. The sensing platform, supported by a flexible polyimide (PI) substrate, consists of a stainless steel (SS) thin film-characterized by a non-flat granular morphology (average grain size ∼364 nm)-decorated with copper oxide nanoparticles (NPs). Fabricated via DC sputtering, followed by optimized thermal oxidation (310 °C for 2 h), the hybrid structure exhibits a distinct catalytic interface with a significant fraction (∼40%) of the glucose-sensitive polycrystalline CuO phase, as estimated by XPS and supported by SAED analysis. Structural characterization via HRSEM, HRTEM, and SAED reveals a uniform distribution of predominantly polycrystalline NPs (average size ∼11 nm) across the SS film, resulting in a high electrical conductivity of 6.7 kS cm⁻¹. Electrochemical analysis demonstrates a sensitivity of 831 µA cm⁻² mM⁻¹ within a linear detection range of 1-5 mM and a limit of detection of 0.13 mM, determined from a linear calibration over the 1-5 mM range. The scalability of the fabrication process, combined with the structural integrity and electrochemical performance, positions the SS film/Cu NP oxide hybrid as a compelling, cost-effective alternative to noble-metal-based sensors for lab-on-chip glucose monitoring with integrated alkaline sample conditioning and, following further adaptation of the electrode and device architecture, a potential wearable medical diagnostic device.

Related

  1. Scalable Fabrication of Stainless Steel–CuO Hybrid Nanostructured Electrodes for Nonenzymatic Glucose Sensing
    Kelly T. C. Thomaz, Jordelson A. A. Junior, Raphael M. V. Rocha +3
    ACS omegaPeer-reviewedCC BYFull textGeneral chemistryEurope PMCCrossref
  2. Hierarchically Porous Nickel Stainless Steel Electrodes for Simultaneous Hydrogen and Formate Production via Membrane-Less Glucose Electrolysis
    Kilaparthi Sravan Kumar, Jesús González-Cobos, Philippe Vernoux +1
    ACS CatalysisPeer-reviewedCC BY 4.0Full text2 citedCatalysisEnvironmental science & pollutionHAL
  3. Imaging Contrast of Diamond Nanoparticle Structures on Different Supporting Films
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral chemistryEurope PMC
  4. Non-Enzymatic Glucose Sensing on NiFeOx-Modified Screen-Printed Carbon Electrodes
    Simona Crispi, Mokhtar Hjiri, Nania Giuseppe +1
    MoleculesPeer-reviewedCC BY 4.0Full textGeneral chemistryCrossrefEurope PMC
  5. Non-Enzymatic Electrochemical Detection of Acephate Using Graphene/Copper Tetraphenylporphyrin Nanocomposite: A Comprehensive Study with Multi-Technique Validation
    Muhammad Tayyab Ishaq, Syeda Aqsa Batool Bukhari, Effat Sitara +2
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
BibTeX
@article{alaferdov2026copper,
  title = {{Copper oxide nanoparticle/stainless steel hybrid structures for non-enzymatic glucose detection}},
  author = {Andrei Alaferdov and Bruna M Hryniewicz and Kelly T C Thomaz and Jordelson A A Junior and Carolina C P Nunes and Fernando I L Leite},
  journal = {Nanoscale advances},
  year = {2026},
  month = nov,
  doi = {10.1039/d6na00575f},
  url = {https://europepmc.org/article/PMC/PMC13795598},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Copper oxide nanoparticle/stainless steel hybrid structures for non-enzymatic glucose detection
AU  - Andrei Alaferdov
AU  - Bruna M Hryniewicz
AU  - Kelly T C Thomaz
AU  - Jordelson A A Junior
AU  - Carolina C P Nunes
AU  - Fernando I L Leite
PY  - 2026
DA  - 2026/11/13
JO  - Nanoscale advances
DO  - 10.1039/d6na00575f
UR  - https://europepmc.org/article/PMC/PMC13795598
AB  - The global prevalence of diabetes necessitates the development of cost-effective, durable, high-performance platforms for glucose monitoring. In this work, a flexible hybrid architecture for non-enzymatic glucose sensing is reported. The sensing platform, supported by a flexible polyimide (PI) substrate, consists of a stainless steel (SS) thin film-characterized by a non-flat granular morphology (average grain size ∼364 nm)-decorated with copper oxide nanoparticles (NPs). Fabricated via DC sputtering, followed by optimized thermal oxidation (310 °C for 2 h), the hybrid structure exhibits a distinct catalytic interface with a significant fraction (∼40%) of the glucose-sensitive polycrystalline CuO phase, as estimated by XPS and supported by SAED analysis. Structural characterization via HRSEM, HRTEM, and SAED reveals a uniform distribution of predominantly polycrystalline NPs (average size ∼11 nm) across the SS film, resulting in a high electrical conductivity of 6.7 kS cm⁻¹. Electrochemical analysis demonstrates a sensitivity of 831 µA cm⁻² mM⁻¹ within a linear detection range of 1-5 mM and a limit of detection of 0.13 mM, determined from a linear calibration over the 1-5 mM range. The scalability of the fabrication process, combined with the structural integrity and electrochemical performance, positions the SS film/Cu NP oxide hybrid as a compelling, cost-effective alternative to noble-metal-based sensors for lab-on-chip glucose monitoring with integrated alkaline sample conditioning and, following further adaptation of the electrode and device architecture, a potential wearable medical diagnostic device.
SN  - 2516-0230
ER  -