Non-Enzymatic Glucose Sensing on NiFeOx-Modified Screen-Printed Carbon Electrodes
- 1National Research Council, Institute for Microelectronics and Microsystems (CNR-IMM), Ottava Strada n. 5, 95121 Catania, Italy
- 2Department of Engineering, University of Messina, 98122 Messina, Italy
- 3Department of Physics, College of Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11623, Saudi Arabia
Abstract
Nickel ferrite (NiFe2O4) nanoparticles were synthesized through a sustainable, plant-mediated route using Hibiscus extract as a natural reducing and stabilizing agent. Three compositions, NiF1 (NH3), NiF2 (NH3 + HTMA), and NiF3 (NaOH + HTMA), were obtained by varying the precipitation conditions. Structural (XRD), morphological (SEM/EDX), and vibrational (FTIR) analyses confirmed the formation of spinel NiFe2O4 with route-dependent crystallinity, crystallite size, and surface chemistry, and increasing hematite (α-Fe2O3) content from NiF1 to NiF3. Electrochemical characterization (CV and EIS) revealed that NiF2 exhibited the highest catalytic activity, fastest charge-transfer kinetics, and the strongest Ni(OH)2/NiOOH activation in alkaline media. Chronoamperometric glucose sensing in 0.1 M NaOH showed that NiF2 provided a more pronounced electrochemical response compared to NiF1 and NiF3 sensors, and lower detection limits (LOD = 0.28 mM). A preliminary proof-of-concept experiment was conducted using a single anonymized plasma sample to evaluate the feasibility of glucose detection in a complex biological matrix. The approach demonstrated stable baselines, low noise levels, and reproducible current variations, enabling the quantification of glucose within a complex physiological matrix. These results highlight the potential of NiFe2O4, synthesized via a plant-extract-assisted approach, as an effective and eco-friendly platform for the development of non-enzymatic glucose sensors.
Related
- Full-Factorial Formulation Screening and Model Protein Sensing with Electropolymerized Molecularly Imprinted Polymer-Modified Electrodes
- Scalable Fabrication of Stainless Steel–CuO Hybrid Nanostructured Electrodes for Nonenzymatic Glucose Sensing
- Insights into the electrochemical behaviour of brominated RNA nucleobases at microband screen-printed graphite electrodes
- Portable and wireless microfluidic impedance sensor functionalized with MnCoPBA@MoS2 nanocomposite screen-printed gold electrodes for on-site bacteria detection
- Fabrication of Pt-decorated MXene–chitosan nanocomposite electrodes for non-enzymatic electrochemical detection of biomolecules
BibTeX
@article{crispi2026nonenzymatic,
title = {{Non-Enzymatic Glucose Sensing on NiFeOx-Modified Screen-Printed Carbon Electrodes}},
author = {Simona Crispi and Mokhtar Hjiri and Nania Giuseppe and Giovanni Neri},
journal = {Molecules},
year = {2026},
month = nov,
doi = {10.3390/molecules31224163},
url = {https://www.mdpi.com/1420-3049/31/22/4163},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Non-Enzymatic Glucose Sensing on NiFeOx-Modified Screen-Printed Carbon Electrodes
AU - Simona Crispi
AU - Mokhtar Hjiri
AU - Nania Giuseppe
AU - Giovanni Neri
PY - 2026
DA - 2026/11/01
JO - Molecules
DO - 10.3390/molecules31224163
UR - https://www.mdpi.com/1420-3049/31/22/4163
AB - Nickel ferrite (NiFe2O4) nanoparticles were synthesized through a sustainable, plant-mediated route using Hibiscus extract as a natural reducing and stabilizing agent. Three compositions, NiF1 (NH3), NiF2 (NH3 + HTMA), and NiF3 (NaOH + HTMA), were obtained by varying the precipitation conditions. Structural (XRD), morphological (SEM/EDX), and vibrational (FTIR) analyses confirmed the formation of spinel NiFe2O4 with route-dependent crystallinity, crystallite size, and surface chemistry, and increasing hematite (α-Fe2O3) content from NiF1 to NiF3. Electrochemical characterization (CV and EIS) revealed that NiF2 exhibited the highest catalytic activity, fastest charge-transfer kinetics, and the strongest Ni(OH)2/NiOOH activation in alkaline media. Chronoamperometric glucose sensing in 0.1 M NaOH showed that NiF2 provided a more pronounced electrochemical response compared to NiF1 and NiF3 sensors, and lower detection limits (LOD = 0.28 mM). A preliminary proof-of-concept experiment was conducted using a single anonymized plasma sample to evaluate the feasibility of glucose detection in a complex biological matrix. The approach demonstrated stable baselines, low noise levels, and reproducible current variations, enabling the quantification of glucose within a complex physiological matrix. These results highlight the potential of NiFe2O4, synthesized via a plant-extract-assisted approach, as an effective and eco-friendly platform for the development of non-enzymatic glucose sensors.
SN - 1420-3049
ER -