δ13C Determination of Benzoic Acid by High-Resolution Orbitrap MS: How Sample Introduction Strategy Governs Accuracy and Precision.

  1. 1Chemistry Institute, Federal University of Goiás, Goiânia74690-900, Brazil.
  2. 2UNIFAL, Universidade Federal de Alfenas, Alfenas37130-001, Minas Gerais, Brazil.
  3. 3PETROBRAS Research and Development Center (CENPES), PETROBRAS , Rio de Janeiro21941-915, Brazil.

Abstract

Stable carbon isotope ratio measurements (δ13C) are traditionally performed by isotope ratio mass spectrometry (IRMS), but recent advances in high-resolution Orbitrap mass spectrometry (Orbitrap MS) enable molecular-level isotope ratio analyses without conversion to simple gases. Here, we systematically evaluate and compare three sample-introduction strategies for Orbitrap-MS-based δ13C determination of benzoic acid─dual-inlet (DI), single-inlet (SI), and automated HPLC flow-injection (column-free mode)─assessing how each governs measurement accuracy and precision. Analyses were performed using paired injections of an isotopically certified benzoic acid reference (IAEA-601) and a benzoic acid sample previously characterized by elemental analysis-IRMS (EA-IRMS), following a seven-block bracketing sequence (Ref-Smp-Ref-Smp-Ref-Smp-Ref) to minimize temporal drift and to generate within-run triplicates. Across all configurations, high analytical precision was achieved, within-block relative standard error (σRSE) consistently below approximately 0.6‰. Under DI conditions, replicate means closely approached the EA-IRMS benchmark (-27.77‰), with residuals of -0.40 to +0.50‰ on the Exploris 240 and -0.58 to -2.73‰ on the Q Exactive. SI analysis enabled the acquisition of a higher number of individual scans per block, contributing to lower σRSE (approximately 0.50-0.65‰) but exhibited larger accuracy offsets (residuals up to approximately 1-3‰), indicating greater susceptibility to systematic bias. Automated HPLC injection on the Exploris 240, optimized for concentration and AGC (50 μmol L-1 and 2.5 × 105, respectively), delivered δ13C values of 28.1‰, -27.19‰, and -27.79‰ (residuals of approximately 0.20-0.45‰) with no significant differences among replicate means (ANOVA/Tukey, 95% confidence level). Collectively, these findings confirm Orbitrap-MS as a reliable alternative to IRMS for δ13C analysis of benzoic acid, and reveal that the choice of injection strategy is the primary determinant of the accuracy-precision-throughput balance achievable with this platform.

Related

  1. Analysis of rubber-derived contaminants in surface water and snow by liquid chromatography coupled with a hybrid linear ion-trap-Orbitrap high-resolution mass spectrometry
    Julie Anquetin, Mathieu Babin, Rachid Amara +1
    Journal of Chromatography APeer-reviewedCC BY-NC-ND 4.0Full text5 citedGeneral chemistryEnvironmental science & pollutionHAL
  2. Alternative Equations and 'Pseudo-statistical' Approaches that Enhance the Precision of Initial Rates for the Determination of Kinetic Parameters
    Ikechukwu Iloh Udema
    IPS Journal of Biotechnology and Applied BiochemistryPeer-reviewedLicence not statedFull text5 citedPhysical chemistryOpenAlex
  3. A Colorimetric Strategy for Arsenic(V) Determination in Rice via Boosting the Peroxidase-like Activity of NCuzyme
    Lei Xu, Mao-Ling Luo, Shan Qiu +3
    MoleculesPeer-reviewedCC BY 4.0Materials & polymersCrossref
  4. Evaluating stationary phase selectivity for retention index determination and resolution of n-hexadecene isomers
    M. Isabel A. Pinto, Tanguy Desbrosses--Lacombre, Priscilla Riva +3
    Scientific ReportsPeer-reviewedCC BYFull textPhysical chemistryDOAJ
  5. Illuminating the Disease Landscape: Human Oxidoreductase-Targeted Imaging and Quantification Agents for Precision Imaging and Activity Determination.
    Nasim Akhtar, Stephy Jomy, Shibalik Mukherjee +1
    Accounts of chemical researchPeer-reviewedCC BYFull textPhysical chemistryEurope PMC
BibTeX
@article{bevilaqua2026δ13c,
  title = {{δ13C Determination of Benzoic Acid by High-Resolution Orbitrap MS: How Sample Introduction Strategy Governs Accuracy and Precision.}},
  author = {Giovanni B Bevilaqua and Hugo G Machado and Júlio C O Ribeiro and Nerilson Marques Lima and Alexandre A Ferreira and Ygor S Rocha and Gabriel F Dos Santos and Boniek Gontijo},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  month = oct,
  doi = {10.1021/jasms.6c00221},
  url = {https://europepmc.org/article/MED/42916763},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - δ13C Determination of Benzoic Acid by High-Resolution Orbitrap MS: How Sample Introduction Strategy Governs Accuracy and Precision.
AU  - Giovanni B Bevilaqua
AU  - Hugo G Machado
AU  - Júlio C O Ribeiro
AU  - Nerilson Marques Lima
AU  - Alexandre A Ferreira
AU  - Ygor S Rocha
AU  - Gabriel F Dos Santos
AU  - Boniek Gontijo
PY  - 2026
DA  - 2026/10/01
JO  - Journal of the American Society for Mass Spectrometry
DO  - 10.1021/jasms.6c00221
UR  - https://europepmc.org/article/MED/42916763
AB  - Stable carbon isotope ratio measurements (δ13C) are traditionally performed by isotope ratio mass spectrometry (IRMS), but recent advances in high-resolution Orbitrap mass spectrometry (Orbitrap MS) enable molecular-level isotope ratio analyses without conversion to simple gases. Here, we systematically evaluate and compare three sample-introduction strategies for Orbitrap-MS-based δ13C determination of benzoic acid─dual-inlet (DI), single-inlet (SI), and automated HPLC flow-injection (column-free mode)─assessing how each governs measurement accuracy and precision. Analyses were performed using paired injections of an isotopically certified benzoic acid reference (IAEA-601) and a benzoic acid sample previously characterized by elemental analysis-IRMS (EA-IRMS), following a seven-block bracketing sequence (Ref-Smp-Ref-Smp-Ref-Smp-Ref) to minimize temporal drift and to generate within-run triplicates. Across all configurations, high analytical precision was achieved, within-block relative standard error (σRSE) consistently below approximately 0.6‰. Under DI conditions, replicate means closely approached the EA-IRMS benchmark (-27.77‰), with residuals of -0.40 to +0.50‰ on the Exploris 240 and -0.58 to -2.73‰ on the Q Exactive. SI analysis enabled the acquisition of a higher number of individual scans per block, contributing to lower σRSE (approximately 0.50-0.65‰) but exhibited larger accuracy offsets (residuals up to approximately 1-3‰), indicating greater susceptibility to systematic bias. Automated HPLC injection on the Exploris 240, optimized for concentration and AGC (50 μmol L-1 and 2.5 × 105, respectively), delivered δ13C values of 28.1‰, -27.19‰, and -27.79‰ (residuals of approximately 0.20-0.45‰) with no significant differences among replicate means (ANOVA/Tukey, 95% confidence level). Collectively, these findings confirm Orbitrap-MS as a reliable alternative to IRMS for δ13C analysis of benzoic acid, and reveal that the choice of injection strategy is the primary determinant of the accuracy-precision-throughput balance achievable with this platform.
SN  - 1044-0305
SN  - 1879-1123
ER  -