Extraocularly Manipulated Flangeless Intrascleral Haptic Fixation of Intraocular Lens Using Zigzag Needles.
- 1Ophthalmology, Osaka Red Cross Hospital, Osaka, JPN.
Abstract
Purpose
To evaluate a novel, flangeless intrascleral intraocular lens (IOL) fixation technique using zigzag 27-gauge needles that prioritizes extraocular maneuvers and eliminates the need for sutures, heat-based flanging, or specialized equipment.Methods
This study evaluated patients who underwent intrascleral IOL fixation with 27-gauge needles at Osaka Red Cross Hospital between March and September 2024. The surgical procedure was performed using a three-piece NX-70 IOL. Standard 27-gauge needles were bent (the leading needle was bent at a slightly obtuse angle and the trailing needle was bent in a zigzag shape in three stages) to guide the IOL haptics extraocularly. Custom silicone pieces (approximately 1 mm, cut from a standard phaco-sleeve) were temporarily attached to the haptic ends to secure them during the process. The haptics were then retracted into limbal-parallel scleral tunnels without flange fixation. Patients were evaluated preoperatively and at one month postoperatively for best-corrected visual acuity (BCVA), corneal endothelial cell density (ECD), and IOL tilt.Results
Eighteen eyes of 17 patients (mean age: 74.3 ± 11.4 years) were included. At one month postoperatively, the mean BCVA improved from 0.56 ± 0.66 logMAR to 0.15 ± 0.40 logMAR. The mean ECD decreased from 2243 ± 319 cells/mm² to 1999 ± 502 cells/mm². The mean IOL tilt was 5.74 ± 2.95 degrees. Postoperative complications occurred in one eye each (5.6%): vitreous hemorrhage (which resolved within two weeks), temporary intraocular pressure elevation, transient corneal edema, and one intraoperative rhegmatogenous retinal detachment (unrelated to the IOL fixation technique itself). IOL repositioning due to tilt was required in one patient (5.6%), and no cases of iris capture were observed.Conclusions
This modified flangeless intrascleral IOL fixation technique using zigzag-bent 27-gauge needles was feasible using standard surgical instruments and yielded acceptable preliminary short-term clinical outcomes in this small case series. Larger comparative studies with longer follow-up are required to evaluate long-term IOL stability and safety.
Related
- Comparative Two-Year Outcomes of Three Different Three-Piece Intraocular Lenses in Flanged Intrascleral Fixation
- Early clinical outcomes of the trans-ocular threading technique for four-point flanged scleral fixation of intraocular lenses: a case series
- Three-Year Functional Vision, Longitudinal Refractive Outcomes, and Patient-Reported Outcomes After Bilateral Implantation of the Extend Bessel-Optics Intraocular Lens: An Independent Real-World Ambispective Study
- Combined scleral suture-fixated intraocular lens implantation and Iris cerclage pupilloplasty for aphakic eyes with traumatic mydriasis
- Intravitreal Nilotinib Reduces Fibroblast Growth Factor-2 Levels in a Rat Model of Dispase-Induced Intraocular Inflammation
BibTeX
@article{sakata2026extraocularly,
title = {{Extraocularly Manipulated Flangeless Intrascleral Haptic Fixation of Intraocular Lens Using Zigzag Needles.}},
author = {Ryo Sakata and Masayuki Akimoto},
journal = {Cureus},
year = {2026},
month = sep,
doi = {10.7759/cureus.116508},
url = {https://europepmc.org/article/MED/42898995},
note = {CC BY},
}
RIS
TY - JOUR
TI - Extraocularly Manipulated Flangeless Intrascleral Haptic Fixation of Intraocular Lens Using Zigzag Needles.
AU - Ryo Sakata
AU - Masayuki Akimoto
PY - 2026
DA - 2026/09/18
JO - Cureus
DO - 10.7759/cureus.116508
UR - https://europepmc.org/article/MED/42898995
AB - Purpose To evaluate a novel, flangeless intrascleral intraocular lens (IOL) fixation technique using zigzag 27-gauge needles that prioritizes extraocular maneuvers and eliminates the need for sutures, heat-based flanging, or specialized equipment.Methods This study evaluated patients who underwent intrascleral IOL fixation with 27-gauge needles at Osaka Red Cross Hospital between March and September 2024. The surgical procedure was performed using a three-piece NX-70 IOL. Standard 27-gauge needles were bent (the leading needle was bent at a slightly obtuse angle and the trailing needle was bent in a zigzag shape in three stages) to guide the IOL haptics extraocularly. Custom silicone pieces (approximately 1 mm, cut from a standard phaco-sleeve) were temporarily attached to the haptic ends to secure them during the process. The haptics were then retracted into limbal-parallel scleral tunnels without flange fixation. Patients were evaluated preoperatively and at one month postoperatively for best-corrected visual acuity (BCVA), corneal endothelial cell density (ECD), and IOL tilt.Results Eighteen eyes of 17 patients (mean age: 74.3 ± 11.4 years) were included. At one month postoperatively, the mean BCVA improved from 0.56 ± 0.66 logMAR to 0.15 ± 0.40 logMAR. The mean ECD decreased from 2243 ± 319 cells/mm² to 1999 ± 502 cells/mm². The mean IOL tilt was 5.74 ± 2.95 degrees. Postoperative complications occurred in one eye each (5.6%): vitreous hemorrhage (which resolved within two weeks), temporary intraocular pressure elevation, transient corneal edema, and one intraoperative rhegmatogenous retinal detachment (unrelated to the IOL fixation technique itself). IOL repositioning due to tilt was required in one patient (5.6%), and no cases of iris capture were observed.Conclusions This modified flangeless intrascleral IOL fixation technique using zigzag-bent 27-gauge needles was feasible using standard surgical instruments and yielded acceptable preliminary short-term clinical outcomes in this small case series. Larger comparative studies with longer follow-up are required to evaluate long-term IOL stability and safety.
SN - 2168-8184
ER -