Early clinical outcomes of the trans-ocular threading technique for four-point flanged scleral fixation of intraocular lenses: a case series
- 1Department of Ophthalmology, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
- 2Department of Ophthalmology, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
- 3Department of Ophthalmology, Seoul St. Mary’s Hospital, 222 Banpo-daero, Seocho-gu, Seoul, 06591 South Korea
Abstract
Purpose: To evaluate the early clinical outcomes and surgical feasibility of a trans-ocular threading technique for four-point flanged scleral fixation of intraocular lenses (IOLs).
Methods: This retrospective case series included 12 eyes of 12 patients who underwent four-point flanged scleral fixation using a trans-ocular threading technique with a preloaded four closed-loop haptic intraocular lens (Artis PE, Cristalens, France). A bent 25-mm long 30-gauge needle was introduced 2.5 mm posterior to the limbus and passed across the anterior chamber to a contralateral corneal incision. During IOL delivery, the needle was threaded through the haptic loops, allowing extraocular suture externalization without intraocular suture handling. A 6 − 0 polypropylene suture (Prolene, Ethicon, USA) was secured using a flanged technique with low-temperature cautery. The anterior chamber was maintained with viscoelastic without an infusion system. Clinical outcomes, including corrected distance visual acuity (CDVA), intraocular pressure (IOP), corneal endothelial cell density (ECD), IOL centration, and postoperative complications, were evaluated at a mean follow-up of 3.2 ± 1.1 months (range, 2–5 months).
Results: At a mean follow-up of 3.2 months (range, 2–5 months), corrected distance visual acuity (CDVA) improved in 10 of 12 eyes (83.3%), with a mean improvement from 0.86 ± 0.72 to 0.38 ± 0.51 logMAR. After suture revision in one eye with early postoperative IOL subluxation due to insufficient suture tension, all IOLs were well-centered at the final follow-up. Mean preoperative and postoperative IOP did not differ significantly (14.9 ± 2.4 vs. 14.1 ± 2.8 mmHg; P = 0.43). Mean corneal endothelial cell density (ECD) was preserved at final follow-up (2205 ± 907 vs. 2146 ± 926 cells/mm²; P = 0.61). Postoperative IOL decentration assessed by anterior segment optical coherence tomography (AS-OCT) was 0.31 ± 0.13 mm (range, 0.04–0.46 mm), with all 12 eyes below the 0.5 mm threshold for clinical significance. One eye developed transient hyphema that resolved spontaneously within one week. No cases of cystoid macular edema, hypotony, or significant intraocular inflammation were observed.
Conclusions: The trans-ocular threading technique for four-point flanged scleral fixation demonstrated favorable early clinical outcomes with minimal complications. This approach may reduce intraocular manipulation and maintain anterior chamber stability without the need for an infusion system.
Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12886-026-05197-7.
Related
- Comparative Two-Year Outcomes of Three Different Three-Piece Intraocular Lenses in Flanged Intrascleral Fixation
- Modified fourth-generation minimally invasive technique with a modified K-wire fixation technique for hallux valgus: a biomechanical and clinical study.
- Clinical Outcomes of Single Intramedullary K-Wire Fixation with Figure-of-Eight Suture Augmentation for Ulnar Styloid Base and Distal Ulnar Metaphyseal Fractures
- Extraocular Haptic Redocking and Vitrector-Assisted Posterior Haptic Manipulation as an Intraoperative Rescue for Intraocular Lens Decentration During the Yamane Technique.
- The 4D Repair Technique for Incidental Durotomy in Spine Surgery: Surgical Technique and Clinical Outcomes in 112 Patients
BibTeX
@article{park2026early,
title = {{Early clinical outcomes of the trans-ocular threading technique for four-point flanged scleral fixation of intraocular lenses: a case series}},
author = {Joo-Ye Park and Woong-Joo Whang and Jae-Jung Kim and Ji-Yun Song and So-Hyang Chung and Hyun-Seung Kim and Yong-Soo Byun},
journal = {BMC Ophthalmology},
year = {2026},
month = aug,
doi = {10.1186/s12886-026-05197-7},
url = {https://doi.org/10.1186/s12886-026-05197-7},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Early clinical outcomes of the trans-ocular threading technique for four-point flanged scleral fixation of intraocular lenses: a case series
AU - Joo-Ye Park
AU - Woong-Joo Whang
AU - Jae-Jung Kim
AU - Ji-Yun Song
AU - So-Hyang Chung
AU - Hyun-Seung Kim
AU - Yong-Soo Byun
PY - 2026
DA - 2026/08/07
JO - BMC Ophthalmology
DO - 10.1186/s12886-026-05197-7
UR - https://doi.org/10.1186/s12886-026-05197-7
AB - Purpose: To evaluate the early clinical outcomes and surgical feasibility of a trans-ocular threading technique for four-point flanged scleral fixation of intraocular lenses (IOLs). Methods: This retrospective case series included 12 eyes of 12 patients who underwent four-point flanged scleral fixation using a trans-ocular threading technique with a preloaded four closed-loop haptic intraocular lens (Artis PE, Cristalens, France). A bent 25-mm long 30-gauge needle was introduced 2.5 mm posterior to the limbus and passed across the anterior chamber to a contralateral corneal incision. During IOL delivery, the needle was threaded through the haptic loops, allowing extraocular suture externalization without intraocular suture handling. A 6 − 0 polypropylene suture (Prolene, Ethicon, USA) was secured using a flanged technique with low-temperature cautery. The anterior chamber was maintained with viscoelastic without an infusion system. Clinical outcomes, including corrected distance visual acuity (CDVA), intraocular pressure (IOP), corneal endothelial cell density (ECD), IOL centration, and postoperative complications, were evaluated at a mean follow-up of 3.2 ± 1.1 months (range, 2–5 months). Results: At a mean follow-up of 3.2 months (range, 2–5 months), corrected distance visual acuity (CDVA) improved in 10 of 12 eyes (83.3%), with a mean improvement from 0.86 ± 0.72 to 0.38 ± 0.51 logMAR. After suture revision in one eye with early postoperative IOL subluxation due to insufficient suture tension, all IOLs were well-centered at the final follow-up. Mean preoperative and postoperative IOP did not differ significantly (14.9 ± 2.4 vs. 14.1 ± 2.8 mmHg; P = 0.43). Mean corneal endothelial cell density (ECD) was preserved at final follow-up (2205 ± 907 vs. 2146 ± 926 cells/mm²; P = 0.61). Postoperative IOL decentration assessed by anterior segment optical coherence tomography (AS-OCT) was 0.31 ± 0.13 mm (range, 0.04–0.46 mm), with all 12 eyes below the 0.5 mm threshold for clinical significance. One eye developed transient hyphema that resolved spontaneously within one week. No cases of cystoid macular edema, hypotony, or significant intraocular inflammation were observed. Conclusions: The trans-ocular threading technique for four-point flanged scleral fixation demonstrated favorable early clinical outcomes with minimal complications. This approach may reduce intraocular manipulation and maintain anterior chamber stability without the need for an infusion system. Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12886-026-05197-7.
SN - 1471-2415