Method Development for a Sensitive and Reliable Quantification of 39 Total Cannabinoids and Their Metabolites by UPLC-MS/MS.
- 1Department of Chemistry and Physics, Kean University, Union, NJ 07083, USA.
Abstract
The global expansion of medicinal and recreational cannabis use has increased interest in the occurrence, metabolism, and environmental fate of cannabinoids. Most analytical methods, however, target Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), and only a limited subset of related compounds. In this study, a rapid UPLC-MS/MS method was developed and evaluated in standard solutions for the simultaneous determination of 39 cannabinoids and cannabinoid metabolites. Chromatographic and mass-spectrometric conditions were optimized, and calibration performance, bias, precision, carryover, detection capability, and chromatographic selectivity were assessed with reference to relevant elements of ANSI/ASB Standard 036. Thirty-eight analytes produced calibration coefficients of determination (R²) ≥ 0.990; 7-OH-CBD produced R² = 0.975 and was retained as a provisionally characterized analyte because its bias and precision remained acceptable, although its calibration performance and LOQ (0.500 ng/mL) were inferior to those of the other analytes. Most critical isomeric pairs achieved baseline separation, whereas Δ9-THCV/Δ8-THCV was only partially resolved (Rs = 1.12). The present results establish a broad-panel method-development foundation in standard solutions. Matrix effects, extraction recovery, stability, dilution integrity, and internal-standard correction must be evaluated before quantitative application to biological, forensic, wastewater, or environmental samples.
Related
- Development and Validation of a UPLC-MS/MS Method for the Determination of Emerging Synthetic, Semi-Synthetic and Related Cannabinoids in Human Hair
- A comparison of fractionation methods for the reliable in vitro quantification of protein digestibility
- Maternal One-Carbon Metabolites and Infant Growth and Development in a South African Cohort with Prenatal Alcohol Exposure
- Development and application of a graded evidence framework for the association between gut microbiota-derived metabolites and diabetic retinopathy
- Development of a pH-sensitive magnetic hydrogel based on chitosan for synergistic chemo/hyperthermia treatment of MCF-7 breast cancer cells
BibTeX
@article{castellanos2026method,
title = {{Method Development for a Sensitive and Reliable Quantification of 39 Total Cannabinoids and Their Metabolites by UPLC-MS/MS.}},
author = {Abigail M Castellanos and Mingjing Sun},
journal = {Toxics},
year = {2026},
month = oct,
doi = {10.3390/toxics14110973},
url = {https://europepmc.org/article/MED/43083583},
note = {CC BY},
}
RIS
TY - JOUR
TI - Method Development for a Sensitive and Reliable Quantification of 39 Total Cannabinoids and Their Metabolites by UPLC-MS/MS.
AU - Abigail M Castellanos
AU - Mingjing Sun
PY - 2026
DA - 2026/10/31
JO - Toxics
DO - 10.3390/toxics14110973
UR - https://europepmc.org/article/MED/43083583
AB - The global expansion of medicinal and recreational cannabis use has increased interest in the occurrence, metabolism, and environmental fate of cannabinoids. Most analytical methods, however, target Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), and only a limited subset of related compounds. In this study, a rapid UPLC-MS/MS method was developed and evaluated in standard solutions for the simultaneous determination of 39 cannabinoids and cannabinoid metabolites. Chromatographic and mass-spectrometric conditions were optimized, and calibration performance, bias, precision, carryover, detection capability, and chromatographic selectivity were assessed with reference to relevant elements of ANSI/ASB Standard 036. Thirty-eight analytes produced calibration coefficients of determination (R²) ≥ 0.990; 7-OH-CBD produced R² = 0.975 and was retained as a provisionally characterized analyte because its bias and precision remained acceptable, although its calibration performance and LOQ (0.500 ng/mL) were inferior to those of the other analytes. Most critical isomeric pairs achieved baseline separation, whereas Δ9-THCV/Δ8-THCV was only partially resolved (Rs = 1.12). The present results establish a broad-panel method-development foundation in standard solutions. Matrix effects, extraction recovery, stability, dilution integrity, and internal-standard correction must be evaluated before quantitative application to biological, forensic, wastewater, or environmental samples.
SN - 2305-6304
ER -