Skip to content
DraconiticResearch
Search Sources API
220,795 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BYAnnals of medicine and surgery (2012)

Orbital volume measurement using direct measurement on 3D-printed models: a comparative study

5 affiliations
  1. 1Department of Ophthalmology, University Lille, CHU Lille, Service de d’Ophtalmologie, Lille, France
  2. 2Oral and Maxillofacial Department, University Bordeaux, CHU Bordeaux, INSERM, Inserm U1026 – Bioengineering of Tissues, Bordeaux, France
  3. 3Department of Oral and Maxillofacial Surgery, University Lille, CHU Lille, Lille, France
  4. 4Public Health Department, University Lille, CHU Lille, URL 2694 – METRICS, CERIM, Lille, France
  5. 5Department of Oral and Maxillofacial Surgery, University Lille, CHU Lille, INSERM, U1008 – Advanced Drug Delivery Systems, Lille, France

Related

  1. Classical vs. Customized Post-Traumatic Orbital Reconstruction with ‘In-House’ 3D-Printed Models: An Extended Cohort Study with Volumetric Analysis
    Elvis Kallaverja, Ida Barca, Francesco Ferragina +3
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Surgery & anaesthesiaCrossref
  2. Nutritional anthropometric indicators predict achievable pocket depth in totally implantable venous access port implantation: a prospective study with 3D-printed measurement device
    Min Hu, Xiangrui Chen, Xiaomei He +3
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textOncologyCrossrefPMC
  3. Finite element analysis of 3D direct-printed shape memory polymer aligners for stress distribution and initial tooth movement in anterior open bite correction
    Hasan Sabah Hasan Al-Nuaimi, Zamri Radzi, Hussein Alnajar +2
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  4. Repeatability of upper limb volume measurements based on the Kuhnke measurement protocol and frustum volume calculation in women after unilateral mastectomy: a cross-sectional methodological study
    Małgorzata Smoter, Robert Roczniok, Jarosław Muracki +3
    Scientific ReportsPeer-reviewedCC BY 4.0Full textOncologyCrossrefDOAJ
  5. Physical Characteristics and Biocompatibility of 3D-printed Poly(lactic-co-glycolic acid) Membranes with Different Lactic-to-Glycolic Acid Ratios for Guided Bone Regeneration: A Comparative Study
    Warote Arayangkool, Guanjuan Liu, Nuttawut Thuaksuban +3
    International Dental JournalPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{massary2026orbital,
  title = {{Orbital volume measurement using direct measurement on 3D-printed models: a comparative study}},
  author = {Mathilde De Massary and Pierre Labalette and Matthias Schlund and Benjamin Bouet and Emmanuel Chazard and Romain Nicot},
  journal = {Annals of medicine and surgery (2012)},
  year = {2026},
  month = oct,
  url = {https://europepmc.org/article/PMC/PMC13754314},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Orbital volume measurement using direct measurement on 3D-printed models: a comparative study
AU  - Mathilde De Massary
AU  - Pierre Labalette
AU  - Matthias Schlund
AU  - Benjamin Bouet
AU  - Emmanuel Chazard
AU  - Romain Nicot
PY  - 2026
DA  - 2026/10/07
JO  - Annals of medicine and surgery (2012)
UR  - https://europepmc.org/article/PMC/PMC13754314
SN  - 2049-0801
ER  -