NanoScope‐Assisted Arthroscopic Repair of a Full‐Thickness Supraspinatus Tear With Concomitant Shoulder Pathology: A Case Report
- 1Florida International University Herbert Wertheim College of Medicine 11200 SW 8th Street Miami 33199 Florida USA fiu.edu
- 2Rutgers New Jersey Medical School 185 S Orange Avenue Newark 07103 New Jersey USA rutgers.edu
- 3OrthoMiami 7800 SW 87th Avenue Suite A110 Miami 33173 Florida USA
Abstract
Case: A 62‐year‐old right‐hand‐dominant woman presented with progressive atraumatic left shoulder pain, weakness, and limited range‐of‐motion (ROM) refractory to conservative management. Examination revealed weakness of the supraspinatus and positive impingement signs. MRI demonstrated a medially retracted full‐thickness supraspinatus tear with subacromial bursitis and acromioclavicular arthrosis. Intraoperative assessment identified a partial tear of the biceps tendon at the superior labral insertion, a degenerative Type‐II superior labrum anterior‐to‐posterior (SLAP) lesion, posterior–superior labral tearing without complete detachment, and glenoid chondromalacia. She underwent NanoScope‐assisted arthroscopic double‐row supraspinatus repair with biceps tenotomy, labral debridement, glenoid chondroplasty, subacromial decompression, acromioplasty, and distal claviculectomy. At 6 weeks, ultrasound (US) demonstrated an intact‐appearing supraspinatus repair without retraction. At 1‐year telehealth follow‐up, the patient reported favorable patient‐reported outcomes, including an American Shoulder and Elbow Surgeons score of 88/100, shoulder surgery questionnaire 8 score of 92.5/100, single assessment numeric evaluation (SANE) scores of 95% for the left shoulder and 90% for the right shoulder, and visual analog scale (VAS) pain score of 0/10.
Conclusion: This case demonstrates the technical feasibility of NanoScope‐assisted arthroscopic repair of a full‐thickness supraspinatus tear with concomitant shoulder pathology.
Related
- Complete pectoralis major rupture with ipsilateral full-thickness supraspinatus tear following a wrestling injury
- Surgical Repair Strategies for Full-Thickness Supraspinatus Tears: A Systematic Review and Meta-Analysis
- Arthroscopic Supraspinatus Repair With Bioinductive and Mechanical Reinforcement Using a Biocomposite Scaffold
- Arthroscopic Reduction and Screw Fixation of Femoral Head Fracture with Concomitant Acetabular Posterior Wall Fracture (Pipkin Type IV)
- Virtual reality-assisted rehabilitation after arthroscopic rotator cuff repair for small-to-medium supraspinatus tears: a prospective assessor-blinded randomized controlled trial
BibTeX
@article{brutti2026nanoscopeassisted,
title = {{NanoScope‐Assisted Arthroscopic Repair of a Full‐Thickness Supraspinatus Tear With Concomitant Shoulder Pathology: A Case Report}},
author = {Jonathan Brutti and Juan Rayo Parra and Klaudia Greer and Zachary Grand and Jan Pieter Hommen and Cesar Ceballos},
journal = {Case Reports in Orthopedics},
year = {2026},
month = nov,
doi = {10.1155/cro/6197200},
url = {https://doi.org/10.1155/cro/6197200},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - NanoScope‐Assisted Arthroscopic Repair of a Full‐Thickness Supraspinatus Tear With Concomitant Shoulder Pathology: A Case Report
AU - Jonathan Brutti
AU - Juan Rayo Parra
AU - Klaudia Greer
AU - Zachary Grand
AU - Jan Pieter Hommen
AU - Cesar Ceballos
PY - 2026
DA - 2026/11/15
JO - Case Reports in Orthopedics
DO - 10.1155/cro/6197200
UR - https://doi.org/10.1155/cro/6197200
AB - Case: A 62‐year‐old right‐hand‐dominant woman presented with progressive atraumatic left shoulder pain, weakness, and limited range‐of‐motion (ROM) refractory to conservative management. Examination revealed weakness of the supraspinatus and positive impingement signs. MRI demonstrated a medially retracted full‐thickness supraspinatus tear with subacromial bursitis and acromioclavicular arthrosis. Intraoperative assessment identified a partial tear of the biceps tendon at the superior labral insertion, a degenerative Type‐II superior labrum anterior‐to‐posterior (SLAP) lesion, posterior–superior labral tearing without complete detachment, and glenoid chondromalacia. She underwent NanoScope‐assisted arthroscopic double‐row supraspinatus repair with biceps tenotomy, labral debridement, glenoid chondroplasty, subacromial decompression, acromioplasty, and distal claviculectomy. At 6 weeks, ultrasound (US) demonstrated an intact‐appearing supraspinatus repair without retraction. At 1‐year telehealth follow‐up, the patient reported favorable patient‐reported outcomes, including an American Shoulder and Elbow Surgeons score of 88/100, shoulder surgery questionnaire 8 score of 92.5/100, single assessment numeric evaluation (SANE) scores of 95% for the left shoulder and 90% for the right shoulder, and visual analog scale (VAS) pain score of 0/10. Conclusion: This case demonstrates the technical feasibility of NanoScope‐assisted arthroscopic repair of a full‐thickness supraspinatus tear with concomitant shoulder pathology.
SN - 2090-6749
SN - 2090-6757
ER -