Arthroscopic Supraspinatus Repair With Bioinductive and Mechanical Reinforcement Using a Biocomposite Scaffold
- 1SportsMed Academy Buenos Aires Argentina
- 2Hombro Integral Caracas Venezuela
Abstract
Rotator cuff repair failure remains a major challenge, particularly in large, chronic, and revision supraspinatus tears. Structural failure is multifactorial and involves both mechanical insufficiency and compromised biologic healing capacity. Retear rates in large and massive tears have been reported between 20% and 70%. Biocomposite‐reinforced scaffolds have been introduced to address both mechanical and biologic limitations. BioBrace (CONMED, Largo, FL) consists of a porous type I collagen matrix reinforced with resorbable poly‐L‐lactic acid microfilaments, designed to provide load‐sharing support while promoting tissue ingrowth. This technical note describes a stepwise arthroscopic double‐row supraspinatus repair incorporating a bioinductive and mechanically reinforced scaffold.
Related
- Aseptic synovitis after arthroscopic rotator cuff repair augmented with a bioinductive collagen implant: a case report and literature review
- All‐Arthroscopic Repair of Partial‐Thickness Upper Border Subscapularis Tear With a Resorbable Bioinductive Bovine Collagen Implant
- Augmentation of Rotator Cuff Repair With a Bioinductive Collagen Scaffold: The Arthroscopic Slide Technique
- NanoScope‐Assisted Arthroscopic Repair of a Full‐Thickness Supraspinatus Tear With Concomitant Shoulder Pathology: A Case Report
- Virtual reality-assisted rehabilitation after arthroscopic rotator cuff repair for small-to-medium supraspinatus tears: a prospective assessor-blinded randomized controlled trial
BibTeX
@article{gomez2026arthroscopic,
title = {{Arthroscopic Supraspinatus Repair With Bioinductive and Mechanical Reinforcement Using a Biocomposite Scaffold}},
author = {Gonzalo Gomez and Myriam Capasso and Geiner M. Gomez and Diego Bourlot and Pablo Colombo and Kennet Fabricio Aguirre Trujillo},
journal = {Arthroscopy Techniques},
year = {2026},
month = nov,
doi = {10.1002/atn2.70314},
url = {https://doi.org/10.1002/atn2.70314},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Arthroscopic Supraspinatus Repair With Bioinductive and Mechanical Reinforcement Using a Biocomposite Scaffold
AU - Gonzalo Gomez
AU - Myriam Capasso
AU - Geiner M. Gomez
AU - Diego Bourlot
AU - Pablo Colombo
AU - Kennet Fabricio Aguirre Trujillo
PY - 2026
DA - 2026/11/08
JO - Arthroscopy Techniques
DO - 10.1002/atn2.70314
UR - https://doi.org/10.1002/atn2.70314
AB - Rotator cuff repair failure remains a major challenge, particularly in large, chronic, and revision supraspinatus tears. Structural failure is multifactorial and involves both mechanical insufficiency and compromised biologic healing capacity. Retear rates in large and massive tears have been reported between 20% and 70%. Biocomposite‐reinforced scaffolds have been introduced to address both mechanical and biologic limitations. BioBrace (CONMED, Largo, FL) consists of a porous type I collagen matrix reinforced with resorbable poly‐L‐lactic acid microfilaments, designed to provide load‐sharing support while promoting tissue ingrowth. This technical note describes a stepwise arthroscopic double‐row supraspinatus repair incorporating a bioinductive and mechanically reinforced scaffold.
SN - 2212-6287
ER -